Instruction/ maintenance manual of the product FXS/DPO/PLAR 1109403L2 ADTRAN
Go to page of 12
® Section 61180403L1-5B Issue 2, December 2004 CLEI Code: VAIMZ70J_ _ 61180403L1-5B 1 Trademarks: Any brand names and product name s included in this docum ent are trademarks, regi stered tradem arks, or trade nam es of their respecti ve holders. CONTENT S 1.
2 Issue 2, December 2004 61180403L1-5B •P L A R D 3 •T a n d e m •D P O • FX Ringdown • TO w/Sealing Code Features The basic features of the FXS/DPO include the following: • µ -law encoding and decoding • Supports ground start, lo op start, PLAR, DPO, and Tandem, TR08SP, TR08UVG, TR08AUTO, and FX Ringdown • Supports 900 ohm s (+2.
61180403L1-5B Issue 2, December 2004 3 Instructions for Inst alling the Module To install the FXS/DPO, perform the following steps: 1. If pres ent, remove the Access Module Blank (P/N 1 175099L1) from the appropriate access module slot of the T otal Acce ss chassis.
4 Issue 2, December 2004 61180403L1-5B Hardware Provisioning DIP switches SW1 , SW2 , SW3 , and SW4 are used to provision many of the FXS/DPO options. Ta b l e 4 on page 5 summ arizes the options pro visioned by the DIP switches. Figure 2 o n page 6 provides a grap hic detail of the four switches and the printed circuit board markings.
61180403L1-5B Issue 2, December 2004 5 T able 4. DIP Switches Sw .-Segment Label Function/Desc ription 1-1 D3/D4 D3 or D4 Signaling (PLAR only) 1-2 1-3 MODE 1/OFF MODE 2/OFF SW1-2 SW1-3 Mode Selected .
6 Issue 2, December 2004 61180403L1-5B Figure 2. DIP Switches Detail Sof tware Provisioning The FXS/DPO is provisioned by connecting a VT100 terminal or a computer ru nning a terminal emulation program to the craft interface ADMIN port located on the System Controller Unit (SCU ) front panel.
61180403L1-5B Issue 2, December 2004 7 . T able 5. FXS/DPO General Opti ons Function Optio n Description Mode Loop S tart Ground Start TR08 Single Part y (3) TR08 Universal VG (3) TR08 Auto (3) PLAR D4 PLAR D3 Ta n d e m (3) DPO FX Ringdown (3) TO w /S C (3) This option selects the signaling mode of the FXS/DPO.
8 Issue 2, December 2004 61180403L1-5B T able 6. FXS/DPO Mode Options Mode Description Loop Start This option selects ANSI T1.403 FXS Loop S tart mode of operation. Ground Start This option selects ANSI T1.403 FXS Ground Start mode of operation. TR08 Single Party This option selects GR-08-Core Loop S tart mode of operation.
61180403L1-5B Issue 2, December 2004 9 T able 7. FXS/DPO T andem Options Function Option Description Conversion Mode T andem Inactive Loop Start Ground Start This option sets the conversion from E&M (2-state) signali ng on the PCM interface to loop star t or ground start signaling on the loop.
Figure 3. FXS/DPO Menu Tree 1. Configuration 2. Provisioning 3. Status 4. Test 1. Digital Network Loopback 2. 1004 Hz Tone Test 2. 2-Wire Termination 1. 600 + 2.16 2. 900 + 2.16 Enter Value (-7.0...+9.0) 3. Transmit TLP 1. Loop Start 3. TR08 Single Party 2.
61180403L1-5B Issue 2, December 2004 11 4. T EST FEATURES The FXS/DPO supports the following tests for each port: • Digital Network Loopback • 1004 Hz Tone Generation • Network Hook Test • Customer Ringing Test These test are used to support circuit turn-up and maintenance efforts.
12 Issue 2, December 2004 61180403L1-5B T able 8. Specifications Performance Loop Current: T ransmit TLP: Receive TLP: T erminating Impedance: Return Loss: T ransHybrid Loss: Longitudinal Balance: Frequency Response: Idle Channel Noise: PCM Encoding/Decoding: DC Supervisory Range: 23 mAmp nom inal 20 mAmp minimum –7.
An important point after buying a device ADTRAN FXS/DPO/PLAR 1109403L2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ADTRAN FXS/DPO/PLAR 1109403L2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ADTRAN FXS/DPO/PLAR 1109403L2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ADTRAN FXS/DPO/PLAR 1109403L2 you will learn all the available features of the product, as well as information on its operation. The information that you get ADTRAN FXS/DPO/PLAR 1109403L2 will certainly help you make a decision on the purchase.
If you already are a holder of ADTRAN FXS/DPO/PLAR 1109403L2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ADTRAN FXS/DPO/PLAR 1109403L2.
However, one of the most important roles played by the user manual is to help in solving problems with ADTRAN FXS/DPO/PLAR 1109403L2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ADTRAN FXS/DPO/PLAR 1109403L2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center