Instruction/ maintenance manual of the product AHDSL2 ADTRAN
Go to page of 30
61221002L2-5B 1 ADTRAN ® AHDSL2 Asynchronous H2TU-C Line Card for Alcatel Litespan ® Channel Bank Assemblies Using Narrowband Pairs Installation and Maintenance Practice Section 61221002L2-5B Issue 2, August 2003 CLEI Code: SLL5R3DG_ _ CONTENTS 1. General .
2 61221002L2-5B Table 1 lists and defines the H2TU-C Front Panel LED indicators. Each ADTRAN Litespan H2TU-C line card provides a 1.552 kbps data transport over one unconditioned CSA copper pair. These CSA loops can range up to 12 kft of 24-AWG twisted pair wire.
61221002L2-5B 3 2. APPLICATIONS The ADTRAN HDSL2 system provides a cost-effective alternative for deploying T1 service over metallic cable pairs. In contrast with traditional T1 service equipment, ADTRAN HDSL2 can be successfully deployed over one unconditioned, nonloaded, bridged-tapped copper pair CSA loop (see Deployment Guidelines , Section 4).
4 61221002L2-5B CAUTION Prior to installing or removing the Litespan H2TU-C, observe the following warning: If the Litespan H2TU-C is removed from a line card slot, wait at least 15 seconds before reinsertion. If connected to the MTI craft interface terminal, wait until the message “AID:MJ,UEQ.
61221002L2-5B 5 Provisioning Commands Upon initial insertion of the Litespan H2TU-C into the Litespan system, configuration options are downloaded automatically to the line card and take precedence over the ADTRAN default provisioning options.
6 61221002L2-5B 1 L T s d n a m m o C t f a r c e t i L s r e t e m a r a P C - U T 2 H s n o i t p O C - U T 2 H s g n i t t e S e l b a l i a v A g n i d n o p s e r r o C s g n i t t e S t f a r c .
61221002L2-5B 7 Testing Commands The H2TU-C testing commands are used to initiate and terminate loopbacks and disconnect for testing purposes. Table 8 lists and defines the TL1/Litecraft testing commands. NOTE Before entering loopbacks, the user needs to remove the card from service.
8 61221002L2-5B Figure 4. Deployment Guidelines Table 9 lists the ADTRAN Litespan H2TU-C and H2TU-R factors needed to calculate channel bank power using Worksheet PW-1. The Table 9 power factors are derived from the power parameters listed in Table 10 .
61221002L2-5B 9 Loop loss per kft for other wire is summarized in Table 11 . Cable Gauge 26 26 24 24 22 22 19 19 Cable Type PIC Pulp PIC Pulp PIC Pulp PIC Pulp Temperature ( ° F) 68 ° 90 ° 120 ° 3.902 4.051 4.253 4.030 4.179 4.381 2.863 2.957 3.083 3.
10 61221002L2-5B Table 13. Troubleshooting Guide Condition At power up, all front panel indicators are OFF The STAT LED remains RED. The STAT LED is OFF, but the HLOS LED remains RED . The STAT LED is OFF, but the RLOS LED remains RED. Solution 1. Verify that the channel bank or ONU BPS power LEDs are on.
61221002L2-5B 11 Table 14. ADTRAN H2TU-C Specifications Loop Interface Modulation Type ............................................... 16 TC PAM Mode .................................................................. Full duplex, partially overlapped echo canceling Number of Pairs .
12 61221002L2-5B This page is intentionally blank..
61221002L2-5B A-1 HDSL MAINTENANCE MODES This appendix describes operation of the HDSL2 system with regard to detection of in-band and ESF facility data link loopback codes. Upon deactivation of a loopback, the HDSL2 system will synchronize automatically.
A-2 61221002L2-5B Table A-1. In-Band Addressable Loopback Codes n o i t c n u Fe d o Ce s n o p s e R 3 n i 1 1 0 0 1. g n i h t y r e v e n w o d p o o L 6 n i 1 1 0 0 0 0 0 1 e r o f e b d e m r a e b t s u m ; k r o w t e n e h t d r a w o t R - U T 2 H e h t t a k c a b p o o L .
61221002L2-5B A-3 n o i t c n u Fe d o Ce s n o p s e R n w o d p o o L 3 , 1 3 9 3 9 1 0 0 1 1 1 0 0 1 0 0 1 1 1 0 0 k c a b p o o l n i y l t n e r r u c s t i n u l l a , r e m o t s u c r o k r o w t e n e h t m o r f t n e s n e h W a e k i l e v a h e b o t r e d r o n I .
A-4 61221002L2-5B This page is intentionally blank..
61221002L2-5B B-1 Appendix B TL1 H2TU-C T utorial GENERAL This appendix is intended to highlight the necessary menus/commands needed to provision the ADTRAN H2TU-C card. A more detailed explanation of shelf specific items may be found in the Alcatel TL1 Reference Practice, OSP-363-205-502.
B-2 61221002L2-5B MAINTENANCE MENU AND ASSOCIATED SUB-MENUS From the Main Menu, enter “2” to display the Maintenance Menu as shown below. Maintenance Menu 1. ADSL Maintenance Menu 2. ATM Maintenance Menu 3. EC1 Maintenance Menu 4. Equipment Maintenance Menu 5.
61221002L2-5B B-3 HDSL MAINTENANCE MENU From the Maintenance Menu, enter “6” to display the HDSL Maintenance Menu as shown below. HDSL Maintenance Menu 1. ALW-MSG-HDSL 2. INH-MSG-HDSL 3. RMV-HDSL 4. RST-HDSL 5. RTRV-ALM-HDSL ← ← ← ← ← Retrieve existing HDSL alarms for the H2TU-C 6.
B-4 61221002L2-5B T1 MAINTENANCE MENU From the Maintenance Menu, enter “20” to display the T1 Maintenance Menu as shown below. T1 Maintenance Menu 1. ALW-MSG-T1 2. ALW-SW-T1 3. CONN-JACK-T1 4. DISC-JACK-T1 5. INIT-REG-T1 ← ← ← ← ← Clears the T1 PM data for the H2TU-C 6.
61221002L2-5B B-5 PROVISIONING MENU From the Main Menu, enter “3” to display the Provisioning Menu as shown below. Provisioning Menu 1. ADSL Provisioning Menu 2. Cross-Connection Menu ← ← ← ← ← Item of interest for the H2TU-C 3. EC1 Provisioning Menu 4.
B-6 61221002L2-5B CROSS-CONNECTION MENU From the Provisioning Menu, enter “2” to display the Cross-Connection Menu as shown below. Cross-Connection Menu 1. DLT-CRS-STS1 2. DLT-CRS-T0 3. DLT-CRS-T1 ← ← ← ← ← Delete an existing cross-connect 4.
61221002L2-5B B-7 ENT-CRS-T1 Command Input Format The choice to enter cross-connects may be accomplished either by selecting “12” from the Cross-Connection Menu or by entering the command directly as shown in the example below where a cross-connect is initiated between slot 1 and slot 21.
B-8 61221002L2-5B HDSL PROVISIONING MENU From the Provisioning Menu, enter “6” to display the HDSL Provisioning Menu as shown below. HDSL Provisioning Menu 1. DLT-HDSL 2. ED-HDSL ← ← ← ← ← Edit HDSL provisioning parameters for the H2TU-C 3.
61221002L2-5B B-9 <ED-HDSL LPBKACTR[]={0000000000000000 | 0000000000000001}; or <ED-HDSL::RT-1-21:::: LPBKACTR ={0000000000000000 | 0000000000000001}; <ED-HDSL LPBKDEACTCDE[]={000000000000000.
B-10 61221002L2-5B Grade of Service tables allow the user to set performance monitoring threshold levels for various alarms/event conditions. There are 15 GOS tables available for each type of service (in our case T1 and HDSL).
61221002L2-5B B-11 <ED-T1 FMT[]={ESF | SF | UNFR | AUTO}; or <ED-T1::RT-1-21::::FMT={ESF | SF | UNFR | AUTO}; <ED-T1 LINECDE[]= {AMI | B8ZS}; or <ED-T1::RT-1-21::::LINECDE={AMI | B8ZS}; TESTING MENU From the Main Menu, enter “4” to display the Testing Menu as shown below.
B-12 61221002L2-5B NOTE Prior to entering any loopback command, the line card must be removed from service. Remove card from service = RMV-HDSL; H2TU-C Network Loopback Loop up command = OPR-LPBK-HDSL.
61221002L2-5B C-1 This appendix describes the testing functionality available for the ADTRAN H2TU-C card via the MTAU unit. For a complete description of the MTAU unit refer to Alcatel document Common Equipment Unit Descriptions , OSP 363-405-250.
C-2 61221002L2-5B Figure C-2 . MON Mode HDSL2 T ransceiver AHDSL2 T est LIU Tip A-3 HDSL2 Loop Ring1 A-4 T AE, RAE EQPT jacks on the MT A U TBE, RBE Alcatel Network Equip MON Mode Used to test tow ard.
An important point after buying a device ADTRAN AHDSL2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ADTRAN AHDSL2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ADTRAN AHDSL2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ADTRAN AHDSL2 you will learn all the available features of the product, as well as information on its operation. The information that you get ADTRAN AHDSL2 will certainly help you make a decision on the purchase.
If you already are a holder of ADTRAN AHDSL2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ADTRAN AHDSL2.
However, one of the most important roles played by the user manual is to help in solving problems with ADTRAN AHDSL2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ADTRAN AHDSL2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center