Instruction/ maintenance manual of the product 1xN ADTRAN
Go to page of 12
1 61190860L1-5B Section 61190860L1-5, Issue 2 CONTENTS 1. GENERAL ................................................................ 1 2. INSTALLATION ....................................................... 3 3. CONFIGURATION ...........................
2 61190860L1-5B Section 61190860L1-5, Issue 2 The SCIM can be locally powered by -48 VDC, or span powered from the standby unit in slot 8 if equipped for span power. Slide switch S1 selects between local or span power. CPE receive and transmit connections are either amphenol or RJ-48C jacks.
3 61190860L1-5B Section 61190860L1-5, Issue 2 Documentation associated with the listed cards provides information on implementing the auto-protect function. LED Indication Table 1 describes LED indication. • All LEDs OFF indicates no power to the SCIM.
4 61190860L1-5B Section 61190860L1-5, Issue 2 Wire-Wrap – The to-facility and from-facility wire-wraps are an alternate method in lieu of the amphenol connections. Customer Side Amphenol Connection – The to-CPE and from-CPE amphenols should be left-side oriented to prevent SCIM panel removal interference after amphenol installation.
5 61190860L1-5B Section 61190860L1-5, Issue 2 Span Power Switch S1 This switch selects between span power or local power. SP AN – The SCIM receives power from the protect card in slot 8. LOCAL – The SCIM receives power from local -48 VDC to terminal strip TB1 on the SCIM card.
6 61190860L1-5B Section 61190860L1-5, Issue 2 the controller card. The controller card will continuously monitor the network receive T1 transmission service in slot 8 (i.
7 61190860L1-5B Section 61190860L1-5, Issue 2 Table 2. In-Band Commands d n a m m o C x e H n r e t t a P n r e t t a P y r a n i B g n i m r A h c t i w S0 4 4 C0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 1 e l b .
8 61190860L1-5B Section 61190860L1-5, Issue 2 7. PROTECTION SWITCH Remote provisioning for a protection switch can be accomplished by sending a specific sequence of in-band or out-of-band messages. These remote provisioning commands are transmitted to the controller card from a remote test facility or a T1 test set at a DSX panel.
9 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Protection Switch Protocol See T able 5 for in-band protection switch protocol. Out-of-Band Enable/Disable Protocol See Table 6 for out-of-band slot enable/disable protocol. Out-of-Band Protection Switch Protocol See Table 7 for out-of-band protection switch protocol.
10 61190860L1-5B Section 61190860L1-5, Issue 2 See Figure 5 and Figure 6 for switchover codes and traffic results. 8. SWITCHBACK Switchback operation is defined as the re-establishment of the T1 transmission path between the network and the customer using the regularly assigned line.
11 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Release Protocol See Table 8 for return to normal operation. Out-of-Band Release Protocol See Table 9 for return to normal operation. Signal Transmit The controller card will transmit a 0 dB signal.
12 61190860L1-5B Section 61190860L1-5, Issue 2 10. SPECIFICATIONS See Table 10 for Specifications. Table 10. Specifications n o i t a c i f i c e p S : e c a f r e t n I l a c i s y h Pe r i W - 4 : l.
An important point after buying a device ADTRAN 1xN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ADTRAN 1xN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ADTRAN 1xN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ADTRAN 1xN you will learn all the available features of the product, as well as information on its operation. The information that you get ADTRAN 1xN will certainly help you make a decision on the purchase.
If you already are a holder of ADTRAN 1xN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ADTRAN 1xN.
However, one of the most important roles played by the user manual is to help in solving problems with ADTRAN 1xN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ADTRAN 1xN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center