Instruction/ maintenance manual of the product Axiom Bunn
Go to page of 17
PR OGRAMMING MANU AL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 41154.
P age 2 41154 110909 BUNN-O-MA TIC COMMERCIAL PRODUCT W ARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years.
P age 3 41154 041708 INTR ODUCTION This equipment will brew a 1 ⁄ 2 gallon batch of coff ee into an awaiting decanter . The brew er may hav e a hot water f aucet f or allied bev erage use . It is only f or indoor use on a sturdy counter or shelf. CONTENTS Adjustments & Programming .
P age 4 ADJUSTMENTS & PR OGRAMMING MAIN SCREEN BREW LOCK OUT This function allows the operator to prev ent or allo w brewing if the water temperature is less than the set READ Y temperature. T o access this functio n screen press and hold the right hidden s witch.
P age 5 - + This function allows the oper ator to adjust the brew v olume. Procedure: 1. Press and hold the right hidden switch until the displa y reads "Bre wWIZARD" and release. 2. The displa y will then read: "BREW OZ: xx.x" 3. Press (-) " Digital " to decrease the amount, or (+) " Control " to increase .
P age 6 ADJUSTMENTS & OPTIONAL SETTINGS (CONT .) ENABLE ADS This function allows the operator to choose wheth - er or not to display an advertising message. An ad can be sav ed to the brewer b y writing the ad usi ng the prog ram ming com mands . Thi s mes sage will be displa yed when the bre wer is idle.
P age 7 NEW AD ? NO YES WRITE T OP LINE ? NO YES 2 LINES 16 CHARS A V AILABLE ENABLE ADS ? NO DONE YES SCROL THRU ALPHA NEXT NEXT LETTER A SCROLL DONE NEXT WRITE BTM LINE ? NO YES SA VE ? NO EDIT YES AD VERTISEMENT SETUP COMPLETE ADJUSTMENTS & OPTIONAL SETTINGS (CONT .
P age 8 SER VICE NUMBER This function allows the operator to enter in the telephone number to call if ser vice is needed. The ser vice number will be display ed anytime there is a f ault message display ed.
P age 9 NO TE: Access to the remaining functions in LEVEL 2 is intended f or tr ained ser vice personnel only . More in depth inf or mation can be found in the Axiom Service Manual 39132.
P age 10 "EASY PULSE BREW" times: Min: Base brew time + 40 seconds Max: Base brew time + 3:00 minutes DRIP TIME 0:30 (-) DONE (+) 0 REFILL 155 (-) DONE (+) ENABLE CLEAN NO DONE YES SET PULSE BREW ? NO YES PROGRAMMING FUNCTIONS - LEVEL 2 (cont.
P age 11 T OO HO T -WILL COOL T ANK NO W A CCURA CY RISK!!! OK CAL. CALIBRA TE NO W? NO YES PLA CE BREWER IN FINAL LOCA TION ENABLE BrewLOGIC NO DONE YES PROGRAMMING FUNCTIONS - LEVEL 2 (cont.
P age 12 SPRA Y OZ/M: XX.X LP1-LP2 OZ XX.X ENTER OZ XX.X (-) DONE (+) W aitingTilCycle 4 CYCLE x COMPLETE CALIBRA TE SPRA Y PRESS BREW ST ART CONT AINER READ Y? QUIT YES PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) When the dispensing finishes , empty the decanter/ser v er and place back under bre w funnel.
P age 13 F A CT OR Y DEF A UL TS NO YES SER VICE T OOLS ? NO YES BREW COUNTERS ? NO YES CALIBRA TE FLO W ? NO YES SPRA Y OZ/M: 25.0 (-) DONE (+) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) View or enter the actual flow rate coming out of the spra yhead. This is used to tell the inter nal controller how fast the water is flowing.
P age 14 PROB ABLE CA USE REMED Y PROBLEM TR OUBLESHOO TING T emperature T oo Low Heating Time T oo Long Fill Time T oo Long T emp Sensor Out Of Range, Check F or Bad Connections T emp Sensor Out Of Range, Check Wire F or Shor ts Equipment will not operate W ater flows into tank continu- ously with po wer remo ved from brew er .
P age 15 PROB ABLE CA USE REMED Y PROBLEM TR OUBLESHOO TING (cont.) Check plumbing and shut-off v alves A) W ait f or the brewer to heat to the proper temperature B) Disable the BREW LOCK- OUT function. Ref er to program - ming section f or procedure.
P age 16 PROB ABLE CA USE REMED Y PROBLEM TR OUBLESHOO TING (cont.) W eak bev erage . BUNN paper filters should be used f or proper extr action F or coff ee, a sufficient quantity of fresh dr ip or regular gr ind should be used f or proper e x- traction.
P age 17 PROB ABLE CA USE REMED Y PROBLEM TR OUBLESHOO TING (cont.) Brew er is making unusual noises. Ser vice required. Plumbing lines should not be resting on the counter top. The bre wer must be connected to a cold water line. W ater pres- sure to the bre wer must not be higher than 90 psi (620 kP a).
An important point after buying a device Bunn Axiom (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bunn Axiom yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bunn Axiom - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bunn Axiom you will learn all the available features of the product, as well as information on its operation. The information that you get Bunn Axiom will certainly help you make a decision on the purchase.
If you already are a holder of Bunn Axiom, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bunn Axiom.
However, one of the most important roles played by the user manual is to help in solving problems with Bunn Axiom. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bunn Axiom along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center