Pr oduct Dat a Model 213A Lega cy t -- RNC S erie s Heat Pump wit h Puron r Refrigerant Si zes 018 to 060 1 - - 1 / 2 To 5 N o m i n a l To n s Fig. 1 – 213A Brya nt’ s heat pum ps wit h Puron r r efr iger ant provi de a col lec tion of features un match ed b y an y oth er family o f eq uip men t.
2 MODEL NUMBER NOMENCLA T URE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 21 3 A N A 0 3 6 0 0 0 0 Pro duct Fa mi ly Tie r SEER Major Series Volt age V ariations Cooling Capaci ty .
3 PHYS ICAL DA T A UNIT SIZE SER IES 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A Operat ing Weig ht (lb ) 146 162 203 207 246 263 279 Shippin g Weight (lb) 169 189 235 239 278 293 311 Compressor T ype Scroll REFRIGERAN T Puron ® (R - - - 410A) Cont rol TXV (Puro n Hard Shutoff) Charge ( lb) 5.
4 ACCESSO RIES ORDER NUM BER DES CRIPT ION 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A HC34GE239 BALL BEARING M O TOR X HC34GE240 BALL BEARING M O TOR X X HC38G.
5 ACCESSO R Y USAGE GUIDELINE ACCESSORY RE QUIRED F OR LOW - - - AMBIE NT COOLING A PPLICATIONS (Below 55 ° F) REQUI RED FOR LONG LINE APPLICATIONS* (Over 80 F t.
6 Accesso ry Descrip tion an d Usag e (Listed A lph ab etical ly) - - CO NTI NUED 10. Outdoor A ir T empe rat ure Se nsor De si gne d for use wi th Brya nt Ther mosta ts l ist ed in t his publi cat ion. This de vice e nable s the ther mosta t to displ ay the outdoor te mper at ure.
7 ELECTRICAL DA T A UNI T SIZ E V/P H OPER VOL TS* CO MPR FAN MCA MIN WIRE SIZE { MIN WIRE SIZE { MAX LENGTH (ft.) } MAX LENGTH (ft.) } MAX FUSE** or CK T BRK AMPS MAX MIN LRA RLA FLA 60 ° C 75 ° C 60 ° C 75 ° C 018 - - - A 208 - - - 230/1 253 197 48 9.
8 DIMENSIONS 213A.
9 213ANA BALANCE POINT WORKSHEET 0 10 20 30 40 50 60 70 80 - - 1 0 0 1 02 03 04 05 06 07 08 0 OUTDOOR TEMPERA TURE , ºF BUILDI NG HEA T LOSS, UNIT I NTEGRA TED HEA TI NG CAP ACI TY , MBTUH 0.
10 COMBINA TION RA TINGS Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 018 - - - A *FY4ANF018 17,100 TDR&TXV 13.
11 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 024 - - - A CNPH*2417A** 22,800 TDR&TXV 14.
12 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A FX4CNF030 29,600 TDR&TXV 14.
13 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A CSPH*3012A* * 29,200 TDR&TXV 14.
14 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 036 - - - A CNPH*3617A** 33,400 TXV 13.
15 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CAP**4221A** 40,000 TDR&TXV 14.
16 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CNPV*4824A** 40,500 TDR&TXV 13.
17 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 048 - - - A CNPH*4821A** 45,000 TXV 13.
18 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capa.
19 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
20 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
21 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
22 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
23 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
24 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System .
25 HEA T PUMP HEA TING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW.
26 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
27 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
28 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
29 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
30 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
31 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l S.
32 GUIDE SPECIFICA TIONS GENERAL System Description Outdoor- - mounted, air- -cooled, split - -system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor , an air - - cooled coil, propeller - -type condenser fan, and a control box.
An important point after buying a device Bryant PURON 213A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bryant PURON 213A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bryant PURON 213A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bryant PURON 213A you will learn all the available features of the product, as well as information on its operation. The information that you get Bryant PURON 213A will certainly help you make a decision on the purchase.
If you already are a holder of Bryant PURON 213A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bryant PURON 213A.
However, one of the most important roles played by the user manual is to help in solving problems with Bryant PURON 213A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bryant PURON 213A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center