352AAV 4-Way Multipoise Two-Stage Condensing Gas Furnace Sizes 060 thru 120 Product Data A05085 Utilizing the extensive resources available to Bryant, a new stan- dard of excellence has been achieved with the model 352AAV Plus 90t TM 4-Way Multipoise Furnace.
—2— 352AAV A05070 NO TE S : 1. Minim u m ret u rn- a ir opening s a t f u rn a ce, bas ed on met a l d u ct. If fle x d u ct i s us ed, s ee flex d u ct m a n u f a ct u rerí s recommend a tion s f or e qu iv a lent di a meter s . 2. Minim u m ret u rn - a ir opening a t f u rn a ce: a .
—3— 352AAV Non-Programmable Thermostat Selection * Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application.
—4— 352AAV SPECIFICATIONS See notes on page 5. UNIT SIZE 036060 036080 048080 048100 060100 060120 RATINGS AND PERFORMANCE Input Btuh† Low 39,000 52,000 52,000 65,000 65,000 7 8 ,000 High 60,000.
—5— 352AAV SPECIFICATIONS Continued * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate the unit 5% from 2000 to 4500 ft above sea level. † Capacity and AFUE in accordance with U.
—6— 352AAV COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE (FT) UNIT MAX INPUT RATE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—7— 352AAV MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT MAX INPUT RATE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
— 8 — 352AAV COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS continued MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.
—9— 352AAV MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT * * Pipe length (ft) specified f or maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowab le pipe length as specified in T able 6.
—1 0— 352AAV CONDENSATE TRAP A93026 1 ⁄ 2 OD INDUCER HOUSING DRAIN CONNECTION 1 ⁄ 4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5 ⁄ 8 OD COLLECTOR BOX DRAIN CONNECTION 1 ⁄ 2 -IN.
—1 1— 352AAV ACCESSORIES CONCENTRIC VENT FOR DIRECT VENT (2-PIPE) APPLICATION (ALL MODEL SIZES) A97110 DIMENSIONS (In.) * Dimension A will change accordingly as dimension D is lengthened or shortened. †Dimension D may be lengthened to 60 in. maximum.
—1 2— 352AAV AIR DELIVERY—CFM (With Filter) • Airflow shown is with factory supplied 1-in. washable filter. • A filter is required for each return air opening. • An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter.
—1 3— 352AAV ELECTRONIC AIR CLEANER HUMIDIFIER A/C COIL VENT COMBU S TION AIR (DIRECT VENT/ 2 PIPE APPLICATION OUTDOOR UNIT AIRFLOW FRONT OF FURNACE A05065 COMBU S TION AIR INLET (NON-DIRECT VENT/.
—1 4— 352AAV COMBU S TION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDEN S ATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT/2-PIPE APPLI.
—1 5— 352AAV.
— 16 — ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 09/09 Catalog No. PDS 352A.
An important point after buying a device Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV you will learn all the available features of the product, as well as information on its operation. The information that you get Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV will certainly help you make a decision on the purchase.
If you already are a holder of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV.
However, one of the most important roles played by the user manual is to help in solving problems with Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center