USER’S MANUAL SMOKE ALARMS M06-2016-008 08/01 Models 4120SB, 4120B, 4120 AC Powered Ionization Smoke Alarm with Battery Back-Up and Silence Feature Cats. 4120SB, 4120SAB Input: 120V AC, 60Hz, 0.05A AC Powered Ionization Smoke Alarm Cat. 4120 Input: 120V AC, 60Hz, 0.
OTHER FEA TURES OF SMOKE ALARMS Battery (DC) operated Smoke Alarms: Provide pro- tection even when electricity fails, provided the batter- ies are fresh and corr ectly installed. Units are easy to install, and do not require pr ofessional installation.
1 WHERE TO INST ALL SMOKE ALARMS INST ALLING SMOKE ALARMS IN SINGLE-F AMIL Y AND MUL TI-F AMIL Y RESIDENCES The National Fire Protection Association (NFP A), recommends one Smoke Alarm on every floor , in every sleeping area, and in every bedroom. In new construction, the Smoke Alarms must be AC power ed and interconnected.
2 More specifically , install Smoke Alarms: • On every level of your home, including finished attics and basements. • Inside every bedroom, especially if people sleep with the door partly or completely closed. • In the hall near every sleeping area.
3 vide reliable early warning protection for those areas separated by a door from the areas pr otected by the required Smoke Alarms. For this r eason, it is r ecommended that the householder consider the use of additional Smoke Alarms for those areas for increased protection.
4 A VOIDING DEAD AIR SP ACES FOR STANDARD, FLAT CEILINGS FOR PEAKED CEILINGS (i.e. Cathedral ceilings, A-frames) Best Location (center of ceiling) Acceptable Location Dead Air Spaces (4&.
5 Read “Where T o Install Smoke Alarms” and “Where Not T o Install Smoke Alarms” before beginning. This unit monitors the air , and when smoke reaches its sensing chamber , it alarms.
6 Read Before Y ou Install This Smoke Alarm (continued)... Never disconnect the power from an AC powered unit to stop an unwanted alarm. Doing so will disable the unit and remove your protection. In the case of a true unwanted alarm open a window or fan the smoke away from the unit.
7 IMPORT ANT INST ALLA TION P ARTS The Mounting Bracket: To r emove the mounting bracket from the Smoke Alarm base, hold the Smoke Alarm base firmly and twist the mounting bracket off. The mounting bracket installs onto the junction box. It has a variety of screw slots to fit most boxes.
8 To Unlock The Battery Compartment (Models 4120B and 4120SB Only) Once the Smoke Alarm is installed, you must disconnect it from the AC power before unlocking the battery compartment. ELECTRICAL SHOCK HAZARD. T urn off the power to the area where the Smoke Alarm is installed before removing it fr om the mounting bracket.
9 To Unlock the Battery Compartment (continued)... 4. T o relock the battery compartment, close the battery door and reinsert locking pin in lock. 5. Reconnect the power connector to the back of the Smoke Alarm, reattach the Smoke Alarm to the mounting bracket, and restore the power .
10 This unit is designed to be mounted on any standard wiring junction box up to a 4-inch size, on either the ceiling or wall. Read “Where to Install Smoke Alarms” and “Where Not T o Install Smoke Alarms” before you begin installation.
11 INST ALLING A SINGLE (ST AND-ALONE) SMOKE ALARM T ools you will need: Standar d/Flathead screwdriver . ELECTRICAL SHOCK HAZARD. T urn off power to the area where you will install this unit at the cir cuit breaker or fuse box before beginning installation.
12 INTERCONNECTING MUL TIPLE SMOKE ALARMS Interconnected units will only work if they are wir ed to compatible units and all requirements ar e met. This unit is designed to be compatible with: BRK Ele.
13 Interconnecting Multiple Smoke Alarms A Unswitched 120V AC 4 Wire Nut 60 Hz Source BT o Additional Units 5 Junction Box Maximum = 18 (Max. 12 Smoke Alarms) 1 Smoke Alarm 6 Neutral (White) AC Wire 2 Ceiling or W all 7 Interconnect Wir e 3 Power Connector 8 Hot (Black) AC Wire To install and interconnect multiple alarms: 1.
14 Model 4120SB Only: During installation, if you accidentally press the Silence button, the alarm will “chirp” once a minute for up to 15 minutes and the T est feature will be temporarily disabled. This is normal. The “chirping” will stop once the alarm r eturns to normal operation.
15 Most carbon zinc batteries have an average service life of 1 year; most alkaline batteries have an average serv- ice life of 1-2 years; most Lithium batteries have an average service life of 6-10 years. Actual service life depends on the smoke alarm and the environment in which it is installed.
16 MODEL 4120SB ONL Y— USING THE SILENCE FEA TURE The Silence feature on this unit can temporarily quiet an unwanted alarm for several minutes. The Silence feature does not disable the unit—it makes it temporarily less sensitive to smoke.
17 PROTECTING YOUR F AMIL Y FROM FIRE Putting up Smoke Alarms is just one step in protect- ing your family from fires. Y ou must also reduce the chance a fire will start in your dwelling, and have a plan for escaping safely if one does.
18 WHA T TO DO IN CASE OF FIRE • Don’t panic; stay calm. Follow your escape plan. Y our safe escape may depend on thinking clear- ly and remembering what you have practiced. • Get out of the dwelling as quickly as possible. Don’t stop to get dressed or collect anything.
19 TROUBLESHOOTING ELECTRICAL SHOCK HAZARD. Always TURN OFF POWER before checking connections or disconnecting any Smoke Alarm! Problem.... Y ou should... Smoke Alarm sounds when • Clean the Smoke Alarm. (See “T esting and Maintenance.”) no smoke is visible.
20 SPECIAL COMPLIANCE CONSIDERA TIONS This unit alone is not a suitable substitute for complete fire detection systems in places housing many people—like apartment buildings, condominiums, hotels, m.
21 LIMIT A TIONS OF SMOKE ALARMS Smoke alarms have played a key role in reducing deaths resulting from home fir es worldwide. However , like any warning device, smoke alarms can only work if they are properly located, installed, and maintained, and if smoke reaches them.
22 Coverage: BRK Brands, Inc. ("BRK") the maker of BRK Electronics ® brand products, warrants that for a period of 10 years from the date of purchase, this product will be fr ee from defects in material and workmanship.
An important point after buying a device BRK electronic 4120 AC (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought BRK electronic 4120 AC yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data BRK electronic 4120 AC - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, BRK electronic 4120 AC you will learn all the available features of the product, as well as information on its operation. The information that you get BRK electronic 4120 AC will certainly help you make a decision on the purchase.
If you already are a holder of BRK electronic 4120 AC, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime BRK electronic 4120 AC.
However, one of the most important roles played by the user manual is to help in solving problems with BRK electronic 4120 AC. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device BRK electronic 4120 AC along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center