238-46789-00F 6/10 SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on the market toda.
2 MINIMUM CLEARANCES (Replaces pg. 9 in instruction manual.) This installation shall allow access to the front of the water heater and adequate clearance shall be provided for servicing and operating this water heater. The water heater may be installed on either a combustible or non- combustible floor.
3 Lighting and Shutdown Instructions (Replaces pg. 18 in instruction manual.) RIGHT INNER DOOR SIGHT GLASS LEFT INNER DOO R PILOT BU RNER THERM OPI LE ELECTRODE.
4 THERMOSTAT ADJUSTMENT (Replaces pg. 19 in instruction manual.) statu s 160°F and 180°F control Figure 2 The gas control knob is set to the “OFF” position when shipped from the factory. Remember that low er temperature settings are more energy efficient.
5 BURNER FLAME CHECK (Replaces pg. 20 in instruction manual.) These models are equipped with self adjusting air mixture and do not have an adjustable air shutter. At periodic intervals, a visual check of the main burner and pilot flames should be made to determine if they are burning properly.
6 INSTALLATION FOR POTABLE WATER (Replaces pg. 24 in instruction manual.) Figure 4.
7 PARTS LIST DRAWING (Replaces pg. 25 in instruction manual.).
8 PARTS LIST (Replaces pg. 26 in instruction manual.) PART NAME AND DESCRIPTION 1. Draft Diverter 14a. Resist ance Temperature Detector 2. Jacket Head Pan 15. Drain Valve 3. Jacket 16. Gas Valve 4. Outer Door 17. Thermal Well 5. Magnesium Anode–Hot Water Outlet 18.
9 THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING (Replaces pg. 27 in instruction manual.) All piping components connected to this water heater for space heating applications must be suitable for use wi th potable water.
10 TROUBLESHOOTING (In addition to instruction manual.) LED Status Control Status Probable Cause None (LED not on or flashing) Millivolt power is not present. Light Pilot Gas valve is not powered. Light pilot. One flash and three second pause. If set point knob is in "PILOT" position then pilot flame is detected.
11 Troubleshooting continued- (In addition to instruction manual.) LED Status Control Status Probable Cause Five flashes and three second pause. Thermostat well fault. 1. Damage to the thermowell wire. 2. Thermowell sensor resistance out of range. 3. Replace thermowell.
12 Notes.
An important point after buying a device Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater you will learn all the available features of the product, as well as information on its operation. The information that you get Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater will certainly help you make a decision on the purchase.
If you already are a holder of Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater.
However, one of the most important roles played by the user manual is to help in solving problems with Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bradford-White Corp Flammable Vapor Ignition Resistant Gas Water Heater along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center