Ethernet Network Interface Unit (ENIU) User Manual 20383 - A1 E N I - E G X X E G X X 1 B Document Number: AIWN-UM-7001-01 Product Catalog: ENI-EGXXEGXX1B CLEI: IPUIA Y5F~~.
R EVISION H ISTORY The Revision Histo ry provides a summary of any changes in this manual. Please make sure yo u are using the latest revision of this manual. August 7, 2006 This manual is available online at ADC’ s website ( www .adc.com/doc umentatio nlibrary/) or yo u can order copies of the manual by contacting you r sales represent a tive.
T able of Content s AIWN-UM-7001-01 iii Chapter 1: Overview ......... ................................. ............................................................. 1- 1 Product Description ............................................................
T able of Content s August 7, 2006 iv AIWN-UM-7001-01.
List of Figures AIWN-UM-7001-01 v Figure 1-1. ENIU with SFPs ........... ............................................... ...................................... 1-1 Figure 1-2. ENIU Front View .......... ............................................... .
List of Figures August 7, 2006 vi AIWN-UM-7001-01.
List of T ables AIWN-UM-7001-01 vii T able 1-1. ENIU LED Indicators and C ontrols ........... ................................ ........................... 1-2 T able 2-1. 10/100 Mbps Ethernet RJ-45 Connector ......... .................................
List of T ables August 7, 2006 viii AIWN-UM-7001-01.
AIWN-UM-7001-01 ix A BO UT T HIS M ANUAL I NTROD UCTION This manual applies to ADC’ s Ethernet Network Interface Unit (ENIU) card (hereaf ter referred to as the “ENIU”).
About This Manual August 7, 2006 x AIWN-UM-7001-01 I NSPECTING Y OUR S HIPMENT Upon receipt of the equipment: • Unp ack each contain er and visually inspect the content s for signs of damage. If the equipment has been dam- aged in transit, immediately repor t the extent of dam age to the transport ation comp any and to ADC.
AIWN-UM-7001-01 1-1 1 Chapter O VERVIEW P RODUCT D ESCRIPTION Delivering a comprehensive set o f Ethernet services requires an intelligent Ethernet network interface unit (ENIU) to serve as the service demarcation point at the edge of the customer's network.
Chapter 1: Overview August 7, 2006 1-2 AIWN-UM-7001-01 F RONT P ANEL Each ENIU has three LEDs, a ST A TUS LED, a LPBK LED, and a LOS/LINK LED. Unde r normal operation the ENIU ST A TUS LED is green. Front p anel indi cators and controls ar e defined in T a ble 1-1 on p ag e 1-2 .
AIWN-UM-7001-01 2-1 2 Chapter I NSTALLATION When using the mounting bracket, allow six inches (15.3 cm) on both en ds of the ENIU for cable access. Inst all the ENIU using the following proce dures.
Chapter 2: Installation August 7, 2006 2-2 AIWN-UM-7001-01 P OWER AND G ROUND C ONNECTI ONS Power and ground connections are loca ted on the back of the ENIU. Ground Connection T o assure pr oper operation, the ground st ud located on the back of the ENIU (see Figure 2- 2 on page 2- 3 ) should be connected to a good earth ground.
August 7, 2006 Chapter 2: Installation AIWN-UM-7001-01 2-3 Power Connection Following local practices, att ach two p a ir of power supply wires fr om two sep arate power sou rces to the four pin power plug (p air 1: -48 VDC-A, RETURN-A a nd pair 2: -48 VDC-B, RETURN-B) on the ch assis backp la ne (se e Figure 2-3 for det ails) .
Chapter 2: Installation August 7, 2006 2-4 AIWN-UM-7001-01 C ABLING RJ-45 cable connections are made to both th e front and rear of the ENIU. DB-9 (command line interface) connection is made on the front an d the power connection is made on the rear .
August 7, 2006 Chapter 2: Installation AIWN-UM-7001-01 2-5 T able 2-1. 10/100 Mbp s Ethernet RJ-45 Connect or T able 2-2. 1000BaseT Ethernet RJ-45 Connector Optical Cables The maximum dist ance that a.
Chapter 2: Installation August 7, 2006 2-6 AIWN-UM-7001-01 DB-9 Communications Cable An RS-232 Craf t port is provided through a DB-9 connector . Refer to your work order to determine the required communications connections. After dete rmining the requir ed con nections , make the necessary connection .
AIWN-UM-7001-01 3-1 3 Chapter C OMMAND -L INE I NTERFACE (CLI) This section lists the commands used to operate the ENIU. Af ter the initial inst allation of an ENIU, most testing and local operations are co nducted with the Command Line Interface through a VT -100 compatible terminal.
Chapter 3: Provisioning August 7, 2006 3-2 AIWN-UM-7001-01 C OMMANDS O VERVIEW All settings are immediately saved. There is no se p arate ‘save’ command. Some settings (for example, save download) do not take ef fect until afte r the next CPU reset.
August 7, 2006 Chapter 3: Provisioning AIWN-UM-7001-01 3-3 Configuration Get Configuration Purpose: Show the current configured p a rame ter s. Command:[all privileges] GET CONFIGURATION Interface S peed and Negotiation Purpose: Configure speed and negot iation mechanism for the NETWOR K a nd SUBSCRIBER interfaces.
Chapter 3: Provisioning August 7, 2006 3-4 AIWN-UM-7001-01 Configure Keep Alive Purpose: Configure “keep alive” mode. When on, the ENIU will not generate an alarm event if the subscri ber interface loses link.
August 7, 2006 Chapter 3: Provisioning AIWN-UM-7001-01 3-5 Craft Port Con figuration Purpose: Configure user interaction with th e command line interpreter . Command:[RW , SECURE privilege] SET IDLE TIMEOUT <minutes> Identifies the number of minut es that the Craft port can remain idle before a logged in user is logged of f.
Chapter 3: Provisioning August 7, 2006 3-6 AIWN-UM-7001-01 Configure OAM for EXFO Operation Purpose: Configure OAM to interoperate with EXFO test equipment in a VLAN environment.
August 7, 2006 Chapter 3: Provisioning AIWN-UM-7001-01 3-7 User and Privilege Settings Purpose: Defines users to the system. Command: [SECURE privilege] SET USER <name> RO|RW|SECURE <password> CLEAR USER <name> User name and p asswords are specified as 1 to 15 alphanumeric characters.
Chapter 3: Provisioning August 7, 2006 3-8 AIWN-UM-7001-01 Configure Optical Thresh olds Purpose: On ENIUs that have optical interfaces, these commands configure the alarm thresholds as sociated with the power levels of the optical connections.
August 7, 2006 Chapter 3: Provisioning AIWN-UM-7001-01 3-9 Exit Purpose: Log of f of a command line session. Command: [all privileges] EXIT Inventory Purpose: Shows hardware and firmware versions as we ll as ADC cat alog and part numbers. Command: [all privileges] GET INVENTORY LED test Purpose: Perform an LED test for the fro nt panel L EDs.
Chapter 3: Provisioning August 7, 2006 3-10 AIWN-UM-7001-01.
AIWN-UM-7001-01 A-1 A Appendix S PECIFICATIONS S pecifications for t he ENIU are listed in T able A-1 . T able A-1. Ethernet NIU Specific ations P ARAMETER SPECIFICA TION Remark s Power Voltage –48VDC, or 110 to 240VAC (50–60 Hz) Operating Voltage +5 VDC Backplane connector Input Current 0.
Appendix A: S pecifications August 7, 2006 A-2 AIWN-UM-7001-01.
AIWN-UM-7001-01 B-1 B Appendix P RODUCT S UPPORT ADC Customer Service Group provides expert pre-sales su ppor t and tr aining for all of it s pro duct s. T echnical support is available 24 hours a day , 7 days a week by contacting t he ADC T echnical Assist ance Center .
Appendix B: Product Support August 7, 2006 B-2 AIWN-UM-7001-01.
AIWN-UM-7001-01 GL-1 G LOSSARY A ALM – Alarm AW G – American Wire Gauge C CLI – Command Line Interfa ce CO – Central Office CPE – Customer Premise Equipment E ENIU – Ethernet Network Inter.
Glossary August 7, 2006 GL-2 AIWN-UM-7001-01.
Certification and W arranty Limited W arranty Product warranty is deter mined by yo ur se rvice agreement. Refer to the ADC Warranty/Sof tware Handbook for additional information, or cont act your sales representative or C ustomer Service for d et ails.
World Headqua rters ADC T elecommunications, Inc. PO Box 1 101 Minneapolis, MN 55440-1 101 USA For T echnical Assist ance T el: 800.366.3 891 Ethernet Network Interface Unit (ENIU) User Manual Documen.
An important point after buying a device ADC Network Unit (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ADC Network Unit yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ADC Network Unit - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ADC Network Unit you will learn all the available features of the product, as well as information on its operation. The information that you get ADC Network Unit will certainly help you make a decision on the purchase.
If you already are a holder of ADC Network Unit, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ADC Network Unit.
However, one of the most important roles played by the user manual is to help in solving problems with ADC Network Unit. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ADC Network Unit along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center