ADCP-90-32 8 • Issue 2 • November 2005 134510 1 Rev A Page 1 © 2005, AD C Telecom municat ions, Inc. FPL Series T ermination/Splice Panel User Manual ) INTRODUC TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADCP-90-328 • Issue 2 • N ovember 2005 Page 2 © 2005, ADC Teleco mmunica tions, I nc. 5.6 Installing FO T Patch Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5.6.1 Interco nnect Applic ation .
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 3 © 2005, ADC Teleco mmunica tions, I nc. Figure 1 s ho ws an exa mple of a te rminatio n only panel , the 72 pos ition model .
ADCP-90-328 • Issue 2 • N ovember 2005 Page 4 © 2005, ADC Teleco mmunica tions, I nc. • Cable Clamp Cov er— prote cts cabl e at entry t o the pan el (n ot prese nt on 12 and 24 positi on panel s).
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 5 © 2005, ADC Teleco mmunica tions, I nc. Figu re 3. 9 6 Posit ion FP L T er minat ion Panel Figu re 4.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 6 © 2005, ADC Teleco mmunica tions, I nc. Figure 5. 12/24 Positio n FPL T ermination Pan el (1RU) Figure 6 sho ws a rear vie w of a ter minati on and s plice panel. The pan el sho wn is the 72 posi tion termina tion and sp lice panel.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 7 © 2005, ADC Teleco mmunica tions, I nc. The fron t sid e of the 72 posi tion te rminat ion an d splice panel is ident ical t o the termin ation onl y panel s ho wn in Figure 1 .
ADCP-90-328 • Issue 2 • N ovember 2005 Page 8 © 2005, ADC Teleco mmunica tions, I nc. 2 ACCESSORIES The foll o wing acce ssory items may be o rdere d separat ely for FPL panels : • Single a nd .
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 9 © 2005, ADC Teleco mmunica tions, I nc. Figure 8 sho ws dimens ions for t he 12/24 po sition 1R U panel. Figure 8. 12/24 Position 1RU Panel 48/ 72/9 6 Pos ition Panel (5 R U) Dimensio ns (H x W x D) 8.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 10 © 2005, ADC Teleco mmunica tions, I nc. Figure 9 sho ws dimens ions of th e 24 pos ition 3R U panel. Figur e 9. Pane l Dimen sions (24 Position 3RU) 16.4 IN. (41.7 CM) 21.9 IN. (55.5 CM) 18.32 IN. (46.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 11 © 2005, ADC Teleco mmunica tions, I nc. Figure 10 sho ws dimens ions o f the 48/7 2/96 posit ion pa nel. Figure 1 0. Panel Dime nsions (48 /72/96 P osition) 16.4 IN. (41.7 CM) 21.9 IN. (55.5 CM) 18.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 12 © 2005, ADC Teleco mmunica tions, I nc. Figure 11 sho ws dimens ions o f the 144 po sition hi gh densit y panel Figure 11. Pane l Dimensio ns (144 Po sition) 16.4 IN. (41.7 CM) 21.9 IN. (55.5 CM) 18.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 13 © 2005, ADC Teleco mmunica tions, I nc. 4 APPLICA TION The FPL Ser ies T erminatio n/Splice Pa nel is de signed for use i n cent ral of fices , remote of fice s, and in lo cal ar ea netw orks (L ANs) that use a f iber o ptic c able syst em.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 14 © 2005, ADC Teleco mmunica tions, I nc. Figure 13. Cross-Connect Appli cation 5 INSTALLATION Instal lation wi ll v a ry dep ending on ho w the panel w as outf itt ed in the fa ctory and ho w it wil l be used.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 15 © 2005, ADC Teleco mmunica tions, I nc. Figure 1 4. Example o f Instal ling Adapter s 5.2 Installing Pigtails Pigtai ls may be in stalled in any FPL pa nel (incl uding te rmination only pane ls) to uti lize the rear area of the pane l for splici ng.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 16 © 2005, ADC Teleco mmunica tions, I nc. Figure 15. Conne ctor Numbe rs on Re ar of 72 Position B ulkhead 4.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 17 © 2005, ADC Teleco mmunica tions, I nc. Figur e 17. Pi gtail Ro uting (24 Posit ion 3RU Pane l) Figure 18.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 18 © 2005, ADC Teleco mmunica tions, I nc. Figure 19. Pig tail Routing (144 Positio n High Density Panel Shown ) 5.3 Mounting the Panel on the Rack Instal lation a lw ays requi res mounti ng the panel on a r ack.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 19 © 2005, ADC Teleco mmunica tions, I nc. The panel ca n be mounted in eit her a 19- or 23-inc h EIA or WECO equipment rac k with eithe r a 4-inch or 5-inch rece ss. The pan el is shippe d with the mounti ng brack ets posit ioned for instal lation i n a 19-i nch rack wit h a 5-i nch reces s.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 20 © 2005, ADC Teleco mmunica tions, I nc. T ypically , only one cable is instal led per panel. The cabl e clamp can be install ed on either side. A groundi ng lug is inclu ded with e ach cl amp for gr ounding OSP ca bles tha t ha ve metalli c stren gth memb ers or m etal lic s heath s.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 21 © 2005, ADC Teleco mmunica tions, I nc. Figure 2 1. Cable C lamp Ass embly (T op Entry) Figure 2 2. Cable C lamp Asse mbly (Bo ttom Ent r y) Note : Rear Prote cti ve Plate sho wn in th ese f igures i s not used on 24 pos itio n panel.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 22 © 2005, ADC Teleco mmunica tions, I nc. 5. A grounding l ug is prov ided for grounding meta llic shea ths and met allic core me mbers. Use the nu t and s cre w pro vided t o fast en the g rounding l ug to the c hassi s at the p oint shown in Figure 23 .
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 23 © 2005, ADC Teleco mmunica tions, I nc. In a t ypical inst allatio n, the met hods and proce dures that wi ll be used for spli cing ar e determi ned b y local pr acti ce.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 24 © 2005, ADC Teleco mmunica tions, I nc. Figure 25. Right Cable Exit (Left as Vi ewed from Rear), 24/48/72/96 Positio n Panel Figure 26.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 25 © 2005, ADC Teleco mmunica tions, I nc. Figure 27. Righ t Cable E xit (Le ft as V iewed fro m Rear), 144 Posit ion Pa nel TOP V IE W (SHOWN WITH T.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 26 © 2005, ADC Teleco mmunica tions, I nc. Figure 2 8. Left C able Exit (Right as Viewed from Rea r),144 Position P anel 6.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 27 © 2005, ADC Teleco mmunica tions, I nc. Figur e 29. Ro uting Bu ndles i nto Spli ce T ray 7. Mark eac h buf fer tube and pigt ail to ind icate the attach ment point to the sp lice tra y . Make sure app roximat ely 2 fee t (61 cm) o f f iber are left be yond the a ttachment point fo r splici ng.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 28 © 2005, ADC Teleco mmunica tions, I nc. Figur e 30. Spli ce T ray Mounted in 24 Posi tion FP L Panel 18.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 29 © 2005, ADC Teleco mmunica tions, I nc. 1. Connect th e FO T eq uipment pa tch cord to t he approp riate b ulk head adapter /rec eptacle a t the fro nt side of the FPL panel as s how n in Figure 31 .
ADCP-90-328 • Issue 2 • N ovember 2005 Page 30 © 2005, ADC Teleco mmunica tions, I nc. 2. Route the patch cor d from the FO T equipment to the re ar side o f the FPL pan el. 3. Connect t he FO T equipme nt patch cord to the ap propri ate b ulk head adapt er/rece ptacl e within t he FPL panel as sho wn in Figure 32 .
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 31 © 2005, ADC Teleco mmunica tions, I nc. 1. Open the f ront co v er of bot h the FO T equipment and OSP-dedic ated FPL pan el. 2. Connect the cross -connec t jumper to th e approp riate bulk head adap ter/rec eptac le at the front s ide of th e f irst F PL panel as sho wn in Figure 33 .
ADCP-90-328 • Issue 2 • N ovember 2005 Page 32 © 2005, ADC Teleco mmunica tions, I nc. 7 CUSTOMER INFORMATION AND ASSISTANCE © 2005, AD C Telecom municat ions, Inc. All R ights Reser ved Printed in U.S.A 13944-RM WRITE: ADC TELECOMMUNICA TIONS, INC PO BO X 1101, MINNEAPOLIS, MN 55440-1101, USA ADC TELECOMMUNICA TIONS (S'PORE) PTE.
ADCP-90-3 28 • Issue 2 • N ovember 200 5 Page 33 © 2005, ADC Teleco mmunica tions, I nc. APPENDIX A: SHIELD CO NNECTOR INSTALLATI ON This append ix pro vides the procedures for instal ling Scotch lok 4460 Shie ld Connector s, which are manuf actured by th e 3M Company an d utilize d in the Fiber Mana gement P anel.
ADCP-90-328 • Issue 2 • N ovember 2005 Page 34 © 2005, ADC Teleco mmunica tions, I nc. Reproduc ed by p ermission o f 3M C ompany, f rom 3M Instructio n Bulle tin, Issue 1, dat ed February 1985, N umber 4 3-7018- 2209-9.
An important point after buying a device ADC FPL Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ADC FPL Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ADC FPL Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ADC FPL Series you will learn all the available features of the product, as well as information on its operation. The information that you get ADC FPL Series will certainly help you make a decision on the purchase.
If you already are a holder of ADC FPL Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ADC FPL Series.
However, one of the most important roles played by the user manual is to help in solving problems with ADC FPL Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ADC FPL Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center