PRINTED IN CHINA 687 p/n 77195 Rev. (-) ECN12792 M 687 05 0207 cps Model: 9600 Single Cup Bre wer OWNERS MANUAL For COFFEE BREWERS MOD ELS : 9600 SINGLE CUP INCLUDES: Installation Operation Use & .
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
MODEL STYLE FEATURES VOLTS WAT TS AMPS 1ø POWER SUPPLY CORD 9600 SINGLE CUP COFFEE BREWER HOT WA T ER DISPENSER 120 VAC 1500 NEMA 5-15P 12.5 1 TABLE OF CONTENTS SPECIFIC ATIONS Thank You for purcha sing this Bloomfield Industries appliance.
FE AT U R E S AN D OP E R AT I N G CO N T R OLS - AUTOMATIC BREWERS 2 Fig. 1 Features & Operating Controls for Single Cup Brewers.
3 PRECAUTIONS A ND GENERAL INFOR M A TION WARNING: ELECTRIC SHOCK H A ZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this w arning can result in electrical shock .
INSTALLATION READ THIS CA REFULL Y BEFORE ST ARTING THE INST ALLA TION Unpack the unit. Inspect all components for co mpleteness and condition. Ensure that all packing materials have been removed from the unit. LEVELING THE UNI T Verify that an adjus table leg is installed at each of the five locations on the bottom of the brewer.
5 INSTALLATION (continued) CAUTION: ELECTRICAL DA MAGE DO NOT plug in or energize this appliance until all Installa tion Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed. NOTE: W ater supply inlet line must meet certain minimum criteria to insure successful operation of the brewer.
6 WARNING: SHOCK H A ZARD Brewer must be properly grounde d to pr ev en t possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury. IMPORTA NT: Supply powe r must m atch nameplate for voltage and phase.
OPERATION 7 A. ST ART- UP For initial start-up, or if the br ew e r has not been used for an extended period of tim e: ♦ Be sure the w ater supply is properly connected and the water supply valve is turned ON . ♦ Be sure that TANK HEATER SWITCH is OFF before co nnecting brewer to electric power.
Fig. 5 Program Brew Select Keys Table I. FOUR BREW OPTIONS OPERATION (continued) 8 B. PROGRAM BREW VOLUMES ♦ Each BREW SELEC T KEY is individually programmable. ♦ Ke y s may be programmed for pulse brewing to optimize c ontact times and extraction rates,.
OPERATION - BREWIN G COFFEE 1. Unlock the pod ho lder by pulling the LOCKING LEVER fully forward. 2. Pull the BREW TRAY fully forward, then lower tray. NOTE: Normally, the brewer will automatically discard the last pod. If the brewer has not bee n used for some tim e, the used pod may need to be removed by hand.
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect br ewer from electric pow er. Allo w brewer to cool. FREQUENCY : Daily TOOLS: Mild Detergent, Clean So ft Cloth or Sponge Bristle Brush, Bott le Brush 1. Disconnect brewer from electric power.
SANITIZING INSTRUCTIONS 11 PROCEDURE: Sanitize Coffee Brewer PRECAUTIONS: None FREQUENCY: W ee kly TOOLS: Pod Sanitizer Packet Em pty Container 1. Unlock the pod holder by pullin g the LOCKING LEVER fu lly forward. 2. Pull the BREW TRAY fully for w ard.
TROUBLESHOOTING SUGGESTIONS 12 SYMPTOM POSSIBLE CAUSE SUGGES T ED REMEDY Water won’t heat Tank heater switch OFF Press switch to ON Brewer unplugged or circuit breaker tripped Check power supply cor.
13 SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access pa ne ls o n this brew ma y expose uninsul ated electrical com ponents. Disconnect brewer from electrical power before removing any pa nel.
14 TEMPERATURE ADJUSTMENT Disconnect brewer from electric power. Pull vent tube out of tank lid and inse rt a thermometer of known accuracy in hole. Reconnect brewer to electrical powe r. Place em pty cup on the c up grid. Ener gize brewer and allow unit to heat.
SERVICING INSTRUCTIONS (continued) 15 IMPORTA NT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN . IMPORTA NT: When mounting thermostat, be sure to insert sensing bulb to the bottom o f the bulb well.
SERVICING INSTRUCT IONS (continued) 16 REPLACE SOLENOID Symptom: Brewer will not flow water; or, brewer drips continuously from pod holder or brew nozzle.
SERVICING INSTRUCT IONS (continued) 17 CAUTION: SHOCK HAZARD DO NOT pour, spill or splash water onto, into or over any internal component. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasiv e or chlorinated cleansers to clean these components.
SERVICING IN STRUCTIONS (continued) 18 IMPORTANT: The two keyp ad ribbon cables connectors ar e not polari zed and can easil y be installed in the wrong position. Be sure to mark t he ribbon cable connectors for orientation. REPLACE CONTROLLER Disconnect brewer from electric power.
SERVICING INSTRUCT IONS (continued) 19 CAUTION: CHEMICAL BURN HA ZA RD Deliming chemicals may be caustic. Wear appropriate protective g loves and go ggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qua lified and experienced service personnel.
EXPLODED VIEW & PARTS LIST 20 CABINET COMPONENTS.
EXPLODED VIEW & PART S LIST (continued) 21 ITEM PA RT N O. DESCRIPT ION QTY 1 (page 22) BRE W DRA W ER ASSY 1 2 87136 UPPER HOUSING, LEFT 1 87175 UPPER HOUSING, CENTER 2 87137 UPPER HOUSING, RIGHT.
EXPLODED VIEW & PARTS LIST 22 BRE W TRAY COM PON ENTS.
EXPLODED VIEW & PART S LIST (continued) 23 ITEM PA RT N O. DESCRIPT ION QTY 51 86946 DRAWER FRONT 1 52 86947 DRAWER PULL 1 53 89861 FRO NT PLAT E 1 54 86951 DRAWER ARM 2 55 85621 ELBOW FITTING 2 5.
EXPLODED VIEW & PARTS LIST (continued) 24 SERVICE PARTS KITS 84427 VALVE ASSEMBLY, COMPLETE 85218 INLET FITTING KIT ( Includes cap, fitting, gask et & strainer) 85219 INLET STRAINER.
25 WIRING DIA GRAM.
PRINTED IN CHIN A Bloo mfiel d Indu stri es, Inc. Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 77 5-6 89-5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
An important point after buying a device Bloomfield 9600 Single Cup (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bloomfield 9600 Single Cup yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bloomfield 9600 Single Cup - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bloomfield 9600 Single Cup you will learn all the available features of the product, as well as information on its operation. The information that you get Bloomfield 9600 Single Cup will certainly help you make a decision on the purchase.
If you already are a holder of Bloomfield 9600 Single Cup, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bloomfield 9600 Single Cup.
However, one of the most important roles played by the user manual is to help in solving problems with Bloomfield 9600 Single Cup. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bloomfield 9600 Single Cup along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center