Instruction/ maintenance manual of the product 2086EX Bloomfield
Go to page of 28
PRINTED IN UNITED STATES OF A MERIC A p/n 73574 Rev. S ECN-1281 7 M652 05 0208 cps 652 OWNERS MANUAL for E-Max™ AIRPOT and THERMAL COFFEE BREWERS MOD EL S 2080 2082 2086 2086EX 2088 2088E X Includes: Installation Operation Use & Care Servicing Instructions Model 2082 Airpot Brewer with optional 7759 Airpot E-Max BREWERS are cov ered under U.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFICATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R OL S 2.
WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels wh ich require the use of tools. Failure to heed this warning can re su lt in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A RTING THE INST A LLA TION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspec t all com ponents for completeness and condition. Ensure that all pack ing materials have been rem oved from the unit.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION IMPORTANT: All E-Max™ brewers are tested and set a t the facto ry . If programming adjust- ments are necessary, refer to the E -Ma x™ Programming Manual (p/n/73674). To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Bre w Wait mode (i.
OPERATION (continued) W ARNING: Burn Hazard. This appliance dispenses very hot liquid. Seriou s bodily injury from scalding can occur f rom co ntact with dispensed liquids. C AUTION: B urn Hazard To avoid splashing or overflowing ho t liquids, ALWAYS use an empty airpot or therm al server before starting th e brew cycle.
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water tem perature on the scre en, the E-Ma x™ brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual wa ter temperature w ill be displayed for 3 seconds.
8. Clock A. Time – Battery Backup. The E-Max™ has a battery backup s ystem which will maintain the proper time during power failures, or when the bre wer is unplugged (even f or very prolonge d periods of time).
OPERATION (cont inued) 12. View Filter Statistics: To view filter stat istics, turn the brewer off . Press and ho ld the 1st k ey (Brew), and depress the 3rd (ON/OFF) k ey. Total water volume will be displayed (TotalVol.). Press the 3rd key to view the Filter Lif e (F ltrLife:).
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Br e wer PRECAUTIONS: Disconnect bre wer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean So ft C loth or Sponge Bristle Brush 1. Dis connect bre wer from electric po w er.
FUNCTION 1. W ater enters at the inlet fitt ing of the fill solenoid (32). The solenoid adm its water via a command from the controller. NOTE: The solenoid has an inter nal strainer. To clean the strain er: Shut of f water supp ly. Unscrew the plastic ca p protruding from the rear of the brewer.
SERVICING IN STRUCTIONS — PLUM BING (continued) ITEM DESCRI PTIO N P ART N0. USED ON 1 2 A SSEMB L Y , WA TE R T ANK (120 V) 83500 201 2, 2072 2015 , 207 5 6 G ASKE T , T ANK LID 83499 AL L 9 T AN K L ID 83504 AL L 10 RET A INING CLIP , T ANK LID 835 06 ALL 1 1 HOSE, OV ERF LOW ( 2 pc SI LI CO N E 4.
SERVICING INST RUCTIONS - ELECTRIC AL FUNCTION 1. Pressing th e POWER k ey energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is accomp lished via a FI LL SOLENOID (32) and a W ATER LEVEL PROBE (7). The probe senses ground through the water in the tank.
SERVICING IN STRUCTIONS - ELECTRIC AL (continued) 15 ITEM DESC R IP TI ON P AR T N0. USED ON 3 PROBE, TEMPERA TUR E 83480 A LL 4 T HERMO S T A T , H I-L IMIT S AF E TY (1 20 V) 839 4 9 2080, 20 82 5 G.
SERVICING INSTRUCTIONS — DE-LIMING HE A TER TANK 1. Disconnect br e wer form the electrica l sup pl y. Turn off the water suppl y and disc onnect water supply f rom the brewer inlet fitting. 2. Rem ove the top panel or top warmer section to gain access to internal components.
TROUBLESHOOTING SUGGESTIONS If the E-Max™ goes into the error diagnostic mode as outlined below , it will likely be necessa ry to reset the brew er in ord er to test individual components.
EXPLODED VIEW & PARTS LIST 18 AIRPOT BREWER MODELS: 2082, 2083, 2088.
EXPLODED VIEW & PARTS LIST (continued) 19 ITEM PART # DESCRI PTION QT 1 8763-1 FAUCE T HOT W ATE R 1 2 83500 83753 84010 TANK ASST 8 QT TANK ASSY 8 QT 240V TANK ASSY 8 QT DUAL VOLTAGE 1 3 83480 TH.
EXPLODED VIEW & PART S LIST (continued) 20 THERMAL BREWER MODELS: 2080, 2085, 2086.
EXPLODED VIEW & PARTS LIST (continued) 21 ITEM PART # DESCRIPTION Q 1 8763-1 FAUCET HOT WATER 1 2 83500 83753 84010 TANK ASST 8 QT TANK ASSY 8 QT 240V TANK ASSY 8 QT DU AL VOLTAGE 1 3 83480 THERMI.
WIRING DIAG RAMS MODEL 2080 & 2082 120 VOLT BREWERS AIRPOT and THERMAL 22 White #8 White #9 White #1 1 Red #3 Black #7 Black #6 Brown #1 Orange/ Black #4 Orange/ Black #5 Red #3 Bro wn #1 Blue #2 Blue #2 Black #6 White #9 White #10 White #8 14 ga .
WIRING DIAGRA MS (continued) MODEL 2086 & 208 8 120/240 VOLT BREWERS AIRPOT and THERMAL 23 Black #12 B l a c k # 4 B l a c k # 5 Red #10 1 2 3 4 Red # 3 Red # 3 Brown #1 Blue #2 Blue #2 Black #6 B.
WIRING DIAGRAMS (continued) 24 MODEL 2086EX & 2088EX 240 VOLT BREWERS AIRPOT and THERMAL.
NOTES 25.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
An important point after buying a device Bloomfield 2086EX (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bloomfield 2086EX yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bloomfield 2086EX - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bloomfield 2086EX you will learn all the available features of the product, as well as information on its operation. The information that you get Bloomfield 2086EX will certainly help you make a decision on the purchase.
If you already are a holder of Bloomfield 2086EX, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bloomfield 2086EX.
However, one of the most important roles played by the user manual is to help in solving problems with Bloomfield 2086EX. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bloomfield 2086EX along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center