Instruction/ maintenance manual of the product 1000 Bloomfield
Go to page of 30
.
INTRODUCTION SAFETY WARNINGS AND PRECAUTIONS xi The technical co ntent of this ma nual represe nts current prod uc tio n m odels as of October, 2003. Data, specifications and materials, and model number designations are subject to change at an y time w ithout no tice.
1 TABLE OF CONTENTS INSTALLATION PROCEDURES …………………………………….. 2 BREWER OVERALL CHECKOUT ……………………………………. 4 BREWING COFFEE …………………………………………………… 5 CLEANING INSTRUCTIO NS ………………………………………….
INSTALL ATION 2 RE A D THIS CAREFULL Y BEFORE ST ARTING THE INST A LLA TION This general information may not apply to all models. Ref er to the owners manual and any te chnical data sheets for your specific equipment for a dditional information. PREPARATION Unpack the unit.
INSTALLATION (continued) 3 NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground .
4 BREWER OVERA LL CHECK-OUT BREWER CHECK-OUT These checks should be performed: • When th e brewer is installe d • During any service call on the brewer • During any subseq ue nt follow-up call IMPORTANT: Tank must be full of water bef ore pressing POW ER key " ON ".
BREWING COFFEE PREPARATION Place on e (1) genuine Bloomfield pa per filter in the brew chamber. Add a pre-measured a mount of fresh coffee gr ounds. Ge ntly shake the brew chamber to level the bed of grounds. Slide the brew chamber into place under the brew head.
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brew er PRECAUTIONS: Disconnect brew er from electric pow e r. Allo w brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean So ft Cloth or Sponge Brist le Brush, Bottle Brush 1. Disconnect brewer from electric power.
THEORY OF OPERATION 7 POUR-OVER FEATURE Pouring any amount of cold wate r into the pour-over opening and into the basin pan forces an identical amount of hot water out of the tank and through the spray he ad into the brew chamber.
The faucet water coil is submerged in the hot water tank an d draws heat from t he bre w water. Faucet water flows through the bypass side of the water inlet and is not cont ro lled by the solenoid val ve. The fauc et is at supp ly water pressure any time the faucet shut-off valve is O PEN .
THEORY OF OPERATION (continued) Heat Control Diagram The heating elements are energized when line power is applied to the elem ent term inals. Water temperature is sensed by a thermobulb inserted in to the water tank.
TROUBLESHOOTING GUIDE 10 QUICK GUIDE The first step in troubleshooting is to determine w h ere to start. A few simple checks should quickly point to the major area of concern.
TROUBLESHOOTING GUIDE (continued) 11 BREW W ATER SY STEM - AUTOMATIC OPERATION.
TROUBLESHOOTING GUIDE (continued) 12 BREW W ATER SYSTEM - AUTOMATIC OPERATION.
.
TROUBLESHOOTING GUIDE (continued) 14 BRE W W ATER SYSTEM - AUTOMA TIC OR POUR-O VER OPERATION.
TROUBLESHOOTING GU IDE (continued) 15 BREW W ATER SY STEM - POUR-OVER OPERATION.
TROUBLESHOOTING GUIDE (continued) 16 FAUCET W ATER SYSTEM.
TROUBLESHOOTING GU IDE (continued) 17 FAUCET W ATER SYSTEM.
TROUBLESHOOTING GUIDE (continued) 18 FAUCET W ATER SYSTEM.
TROUBLESHOOTING GU IDE (continued) 19 ELECTRICAL SYSTEM - BREW CA UTIO N: ELECTRIC SHOCK HA ZARD Exposed electric circuits. Use due caution when work in g near live ele ctric circuits.
TROUBLESHOOTING GUIDE (continued) 20 ELECTRICAL SYSTEM - HEATING.
.
SERVICING INSTRUCTIONS 22 TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid an d insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power. Place an empty decanter under brew chamber.
SERVICING INST RUCTIONS (continued) 23 IMPORTA NT: Water pressure must be betwee n 20 p.s.i and 90 p.s.i. flowing pressure. If wate r pressure ex ceeds this value, or if water pressure varies g reatly, a pres sure regulator must be installed in the w ater sup ply line.
.
25 SERVICING INST RUCTIONS (continued) IMPORTA NT: When replacing water faucet coil, also rep l ace seal gaskets. NOTE : Any ab ra sion or roughness on the flat end of the seat cup will re quire replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem.
26 CA UTIO N - CH EMICA L BU RN HA Z A RD Deliming chem icals are caustic. W ear ap pr op riate pr ote ct ive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
27 7. Set the tank ba ck into the brewer. Reassem b le the tank lid to the water tank. Mak e sure the gasket is properly in place, then reinstall the hold-do wn strap. 8. Reinstall wiring to heating element a nd thermostat. Reinstall the hi-lim it thermostat (if removed).
Bloo mf iel d Indu str i es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -6 89-5700 Fa x: 888 -492- 2783 Fa x: 800 -356- 5142 () websi te: www .
An important point after buying a device Bloomfield 1000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bloomfield 1000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bloomfield 1000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bloomfield 1000 you will learn all the available features of the product, as well as information on its operation. The information that you get Bloomfield 1000 will certainly help you make a decision on the purchase.
If you already are a holder of Bloomfield 1000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bloomfield 1000.
However, one of the most important roles played by the user manual is to help in solving problems with Bloomfield 1000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bloomfield 1000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center