DC7000 Dat a Collection T erminal Hardwar e Manual.
2 FCC Warning: Note: This equ i pment has bee n tested and fo und to com ply with th e limits f or a Cl ass A digital device, pursuant to Part 15 of the FCC rules. These lim its are designed to provide reasonabl e prot ection agains t harmful i nterfer ence when the e quipment is operat ed in a commer cial envi ronment .
3 The telephone c ompany may make change s in its facil ities, equipment, operations or procedure s that coul d aff ect the ope rati on of the equipment. If this happens the tele phone company will provide advanc e noti c e in orde r for you to make n ecessar y mod ifications to mainta in uninterru pted serv ice.
4 Declar ation Of Conf ormity Accordi ng To EMC Di rective 89/ 336/EEC We declare under our sole responsibi lity that the DC7000 magnetic stripe and/or barc ode readin g and/or d ata recordin g equipm.
5 Table of Contents 1. Introd uction ................... .................................... ............... ............ 6 Basic Hardware an d Vari ations ...................... ............................................6 General Specif ications .
6 1. Introduction Basic h ardware and vari ati ons The elec tronic hard ware is a n ew, versat ile platform designed for use with va rious applications. This manual describes, in deta il, the e lectronic hard ware aspects of the terminal you have purchased.
7 F. Display: Backlit, Blue Ba ckgrou nd, 2 lines with 20 charac ters on each line. G. Keypad: Full travel keys with elasto meric cont act pad, 4 rows x 4 columns. H. Seri al Port: RS- 232 using 6 positi on (4 contact) RJ-11 mo dul ar connection. I. Serial Por t: RS-485 ( Local Area Networ k) usi ng RJ-11 mod ular connec tion.
8 2. Setup Operating Environment The terminal can be inst alled in any normal office or controlled factory environment. However, do not use the terminal under the following conditions: • extremely h.
9 Mounting Unscrew the access door. With the d oor off, the main unit can slide upward and be removed from the mount ing brack et. The bracket can be used for wall mounting, or it can be reversed to tilt the unit on a desktop.
10 3. Operator Interface Keypads The standard terminal keypad has 16 keys for entering alphabetical and numeric data as illustrated below. S tandard Alpha-Numeric Keypad MEN U MENU O p tional Numeric .
11 Card Readers The DC7000 is availa ble with (3) types of ca rd readers. a) Magnetic stripe card reader . The magnetic stripe on the card should be on the right side as shown in the illustration. b) Internal barcode reader. Infrared or visible barcode readers are available.
12 c) Proximity Readers Two Proximity Readers are available on the DC7000. The first Proximity Reader uses 125kHz, Read Only, ISO Proximity C ard, 64 Bit Encoding (Manchester). Serial Output Data String contains a 9 Bit Header, 40 Bits of Data, 14 Pa rity Bits and 1 Stop Bit.
13 Wireless WiFi Connection The Wireless Ethe rnet connection is established via Wireless 802.11b. RS-232 Serial port The RS-232 serial port is located on the lower left corner of the terminal. It is a six posi tion 4-pin female port, wh ich wi ll accept a male RJ-11 modular connector.
14 See Page 24 for USB to RS-232 Adaptor. (Use DB-25 RS -232 Host Ca ble Ass y . See pp. 24-25) Cabling to Host Computer with DB-25 Port NOTE: S chemati c c onnect ions are shown fr om END V IEW (a s viewed from the out side of t he connector s). Schematic Schematic (Use DB-25 R S-232 Host C able Ass y .
15 Local Area Network: RS-485 Serial Port The RS-485 serial port is located on the lower left corner of the terminal. It is a six position 6-pin fe male port with the outer 2 pins to Ground.
16 RS-485 Serial Cables Junction Box “Daisy Chai n” Wiring Diagram RS485 Wiring Diagram The RS485 Serial port i s locat ed on t he left corner of the te rminal. RS485 i s imprinted on the terminal casing. A A RS485 communication all ows up to 32 termina l s to be conn ected t o one seri al por t.
17 Modem Port The port depicted may have either an RS- 485, a Modem, or an Ethernet Communication Device. Terminals, which are equipped with a Modem port, will not have an Ethernet or RS-485 port. The Modem Port is a 6 position 4-pin female port, which will accept a male RJ-11 modular connector.
18 Modem Cables Caution – To reduce the risk of fire, use only 26 AWG or larger telecommun ication line cord. The cabling for modem operation is t ypically very simple. The modular connection uses the two inner wires of the RJ- 11 jack for “tip” and “ring.
19 Wand Port The Wand port is located on the left si de of the terminal. I t is a 6-pin DIN port that accepts a ci rcular DIN connector. The Wand, when connected, uses only 3 of the 6 pins available on the DIN connection. If a Ba rcode Gun (non-contact reader) is used, the center pin supplies add itional power.
20 Wand and Y-Cable Disconnect power to the terminal before connecting the Barcode W a nd. The wand is capable of readi ng bar code stripes by passing it directly ove r the label. Check th e software manual to i dentify the codes your terminal will read.
21 Parallel Port The parallel port is located on the ba ck right of the DC7000 Terminal. It is a 25 pin female port, which will ac cept a 25-pin male connector . This type of parallel port is typically used on IBM ® PC or IBM-PC compatible computers.
22 Parallel Cable The parallel port is used for additi onal digital I/O or for printing. A standard parallel p rint cable is used with a simple ASCII parallel printer.
23 5. CompanionPr oducts Read er s Description / Illustration P a r t N u m b e r Barcode Wa nd 74-0106-002 and Hold er Power Supplies Descripti on/Illustrati on Part Number 120VAC t o 9VAC, 1A 56-011.
24 External Rela y Box, External Buzzer External Relay Box 120 V 01-0121-000 External Buzzer 01-0122-000.
25 Cables Descripti on/Illustrati on Part Number “Standard” Modula r Cable length - 7 feet 72-0146-000 - 5 0 f eet 72-0146-004 Y-Cable (s plitter) 72-0159-000 DB-25 RS-232 Host Cable Assembl y Includes DB-2 5 Female (RS- 232/host) to RJ-11 Female adaptor and “Standard” Modular Cable.
26 Cables, Converter, Badge Racks Descr ipti on / Il lustrat ion Part Number Modem Adapto r Cable Assembl y Includes DB-25 Male (modem) to RJ-11 male adaptor and “Sta ndar d” Modular Cable.
27 6. Appendix Units with Acroprint Data Co llecti on Firmware Acroprint Data Collection Terminal Setup Instructions Configuring procedure for en tering the DA TE & TIME: Swipe the C o nfiguration.
28 (For RS485 terminals only) Select opti on 1 for RS485 <pre ss ENTER> Select the baud rate 0 for 1200, 1 for 2400, 2 for 48 00, 3 for 9600 and 4 for 19,200 baud.
29 Configuring procedure fo r selecting the READERS: Swipe the C o nfiguration Badge 00000 0 000 (This badge is provided w ith each terminal.) Select opti on 3 to ACTIV A TE READERS <press ENTER >. (Select any combination 1234 to activat e the r eaders.
30 Electrical Connections Parallel Port Connector on DC7000 Digital IO Mode Printer Mode 1 Digital I O #7 1 St robe 2 Dig ital IO #8 2 Printer D ata 0 3 Dig ital IO #9 3 Printer D ata 1 4 Dig ital IO .
31 DC7000 Wand Connector Socket 1 +5 Volts 2 Signal Control Logi c Line (Dig ital IO #0 - Output On ly) 3 Barcode Wand Receive Date 4 Ground 5 Access Logic Line (Dig ital IO #1 - Output On ly) 6 +12 V.
32 DC7000 RS485 / Modem C onnector Modem R S 4 8 5 1 Not Used 1 GND 2 N/A 2 N/A 3 TIP 3 Data (-) 4 RING 4 Data (+) 5 N/A 5 N/A 6 Not Used 6 GND DC7000 Ethernet Connector 1 Data (TX +) 2 Data (TX -) 3 .
33 Specific ations IO Points 0–1 Output High: 4.0 milliamps o ut of MA X, V o ut = 4.2 Volts MIN Low: 4.0 milliamps in MAX , V out = 0.4 Volts MAX Input: Not Applicable IO Points 2–15 Output High: 1.6 milliamps o ut of MA X, V o ut = 2.4 Volts MIN Low: 2.
34 This page intentionally left blank.
35 This page intentionally left blank.
36 5640 Departure Drive Raleigh, NC 27616 919.872.5800 www.acroprint.com P/N 06-0333 -000 Rev. B.
An important point after buying a device Acroprint DC7000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Acroprint DC7000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Acroprint DC7000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Acroprint DC7000 you will learn all the available features of the product, as well as information on its operation. The information that you get Acroprint DC7000 will certainly help you make a decision on the purchase.
If you already are a holder of Acroprint DC7000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Acroprint DC7000.
However, one of the most important roles played by the user manual is to help in solving problems with Acroprint DC7000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Acroprint DC7000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center