V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.
www .zephyronline.com.
T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ......
www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a.
List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1.
www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft .
5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28".
www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option.
7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound.
www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4.
9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters.
www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency .
11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.
www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory .
13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser.
www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot.
15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON.
List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36”.
www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects.
An important point after buying a device Zephyr ZVE-E30S (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Zephyr ZVE-E30S yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Zephyr ZVE-E30S - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Zephyr ZVE-E30S you will learn all the available features of the product, as well as information on its operation. The information that you get Zephyr ZVE-E30S will certainly help you make a decision on the purchase.
If you already are a holder of Zephyr ZVE-E30S, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Zephyr ZVE-E30S.
However, one of the most important roles played by the user manual is to help in solving problems with Zephyr ZVE-E30S. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Zephyr ZVE-E30S along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center