Instruction/ maintenance manual of the product ZHC 950 Zanussi
Go to page of 20
C OOKER HOOD ZHC 950 INSTRUCTION BOOKLET.
.
Customer Care Department Zanussi 55 - 77 High S treet Slough Berkshire SL1 1DZ T el: 08705 727 727 T o register ownership, please ensure you complete and return the guarantee card supplied with the appliance.
These warnings are provided in the interests of safety . Ensure that you underst an d them all before installing or using this appliance. Y our safety is of paramount impor- tance. If you are unsure about any of the meanings of these warnings contact the Customer Care Department.
3 YOUR APPLIANCE OPERA TING INSTRUCTIONS This cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam. Cooker Hood Controls The cooker hood functions are controlled by four push button switches located centrally in the control fascia.
T o Operate Select the required fan speed and light if required. The appliance can be installed to recirculate or extract contaminated air . The cooker hood is more effective when used in the extraction mode. Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted.
Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply . The cooker hood must be kept clean, as a build up of grease or fat can be a fire hazard. External Cleaning Wipe the cooker hood frequently with warm soapy water using a mild detergent.
Position the new charcoal filter in the position marked and while holding the filter replace the fixing hooks as illustrated. This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended. Changing the Light Bulb Remove the screw fixing the lighting support.
If, having followed these instructions carefully , your cooker hood fails to work properly please carry out the following checks. SOMETHING NOT WORKING Symptom The cooker hood will not start The cooker hood is not working effectively • Check the hood is connected to the electricity supply .
8 GUARANTEE CONDITIONS We, Zanussi, undertake that if within twenty four months of the date of the purchase this Electrolux built-in product or any part thereof is proved to be defective by reason onl.
INST ALLA TION INSTRUCTIONS It is dangerous to alter the specifications or attempt to modify this product in any way . T echnical information DIMENSIONS HEIGHT OF CANOPY : (incl glass visor) 52mm HEIG.
INST ALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown. All installations must comply with the local authorities requirements for the discharge of exhaust air. Incorrect installation may affect the safety of this cooker hood.
11 Clearance Heights The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated, providing the maximum output of the appliance beneath does not exceed the maximums quoted in the T echnical Specifications.
Fix the lower bracket item 7.2.1 using two 4.2x44.4 wall fixing screws item 12a . Fix the upper fixing bracket item 7.2.1 and the recirulation outlet support item 7.3 together using two 4.2x44.4mm wall fixing screws item 12a as illustrated. Insert two 4.
Fitting the Hood Body Before starting to fix the hood body , tighten the two screws Vr located on the top of the hood body . Hook the hood body onto the two 4.2x44.4mm screws item 12a . Fully tighten the screws item 12a . Using a screw driver and spirit level, adjust the screws item V r until the hood body is level.
Extraction The charcoal filter is not required in this mode and should be removed. Ducting The ducting used must be Ø150mm (6ins), or Ø125mm (5ins) in diameter . If possible duct through the wall immediately above the hood body . For the best performance use the shortest possible duct run and the minimum number of bends.
15 Fitting the Chimney Stack The chimney consists of two sections. The lower chimney measures 740mm and the upper chimney (with the recirculation grilles on either side) measures 465mm. The overall installed measurement is min. 870 - max 1200mm. UPPER CHIMNEY T o fit the upper chimney section item 2.
.
.
43600 1681 0 1 - 0 30210 © Electrolux plc 2002.
An important point after buying a device Zanussi ZHC 950 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Zanussi ZHC 950 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Zanussi ZHC 950 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Zanussi ZHC 950 you will learn all the available features of the product, as well as information on its operation. The information that you get Zanussi ZHC 950 will certainly help you make a decision on the purchase.
If you already are a holder of Zanussi ZHC 950, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Zanussi ZHC 950.
However, one of the most important roles played by the user manual is to help in solving problems with Zanussi ZHC 950. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Zanussi ZHC 950 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center