Instruction/ maintenance manual of the product FRCS024 York
Go to page of 16
036-21004-002 Re v . B (0602) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT -SYSTEM AIR CONDITIONERS 14 SEER MODELS: FRCS024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuo us product impr ovement, specifica tions are subjec t to change without notice .
036-21004-002 Rev. B (0602 ) 2 Unitary Products Group Physical and Electr ical Dat a MODEL FRCS0241BD FRCS0301BD FRCS0361CD FRCS0421CE FRCS0481CE F RCS0601BF Unit Supply V oltage 208 / 230 - 1 – 60 Normal V oltage Range 1 187 to 252 Minimum Circuit Ampacity 12.
036-21004-002 Rev. B (0602) Unitary Products Group 3 - = Not applicable COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 14 SEER AC WITH N-AH / G2FD FRCS0241BD N1AHB0806 2,5,8,10 17 G2FD036S17 800 25.
036-21004-002 Rev. B (0602 ) 4 Unitary Products Group COOLING CAP ACITY - Upflow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL S EN S.
036-21004-002 Rev. B (0602) Unitary Products Group 5 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. FRCS0601BF 1650 2150 21,24 G1F A060S21,24 1900 53.
036-21004-002 Rev. B (0602 ) 6 Unitary Products Group 1. For condensing unit only . Does not include ef fe ct of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increa se capacit y 1% for e ach 2° in crease in sub-cool ing.
036-21004-002 Rev. B (0602) Unitary Products Group 7 TYPICAL INST ALLA TION TYPICAL FIELD WIRING MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA W.
036-21004-002 Rev. B (0602 ) 8 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602) Unitary Products Group 9 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602 ) 10 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602) Unitary Products Group 11 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602 ) 14 Unitary Products Group MA TCHING INDOOR COMPONEN TS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain p an.
036-21004-002 Rev. B (0602) Unitary Products Group 15 NOTES.
Subject to change without notice. Printed in U.S.A. 036-21004-002 Rev. B (0602) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 036-2100 4-002 Rev.
An important point after buying a device York FRCS024 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought York FRCS024 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data York FRCS024 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, York FRCS024 you will learn all the available features of the product, as well as information on its operation. The information that you get York FRCS024 will certainly help you make a decision on the purchase.
If you already are a holder of York FRCS024, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime York FRCS024.
However, one of the most important roles played by the user manual is to help in solving problems with York FRCS024. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device York FRCS024 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center