271846-YTG-B-0208 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 APPLICATION FLEXIBILITY . . . . . . . . . . . . . . . . . . . 3 CABINET . . . . . . . . . . . . . . . . .
271846-YTG-B-0208 Johnson Controls Unitary Products 3 DESCRIPTION These units are completely asse mbled, piped, wired, charge d and tested at the factory and are shipped ready for immedia te installation.
271846-YTG-B-0208 4 Johnson Controls Unitary Products FACTORY INST ALLED OVERSIZED EVAPORATOR FAN MOTORS Increased horsepow er motors and drive components are available for those applicatio ns where external static pres - sure requirements exceed the capability of the standard motor .
271846-YTG-B-0208 Johnson Controls Unitary Products 5 NOTE: Cooling performance is ra te d at 80°F dry bulb 67°F wet bulb entering air temperatu re, CFM listed, 85°F enterin g 95°F leaving water temperature, and water flow rate list ed. Gross capacity does not include the effect of evapora - tor fan motor heat.
271846-YTG-B-0208 6 Johnson Controls Unitary Products NOTE: Cooling performance is ra ted at 80°F dry bulb 67°F wet bulb entering a ir temperature, CFM listed, 85°F entering 95°F leaving water temperature, and water flow rate list ed. Gross capacity does not include the effect of evapora - tor fan motor heat.
271846-YTG-B-0208 Johnson Controls Unitary Products 7 NOTE: 1. At higher evaporator airflows, and wet bulb conditions condensate ca rry -over may occur. Adjust airflow downward as necessar y. 2. Values include pressure drop from wet coil and cle an filters.
271846-YTG-B-0208 8 Johnson Controls Unitary Products NOTE: At higher evaporator airf lows and wet bu lb conditions, condensate carry-over may occu r . Adjust airflow downwa rd as necessary V alues include pressure drop from wet coil and clean filter s.
271846-YTG-B-0208 Johnson Controls Unitary Products 9 T ABLE 6: W ATERSIDE PRESSURE DROP - CU MODELS CU060 CU096 CU120 CU180 CU240 CU300.
271846-YTG-B-0208 10 Johnson Controls Unitary Products T ABLE 7: WATER PRESSURE DROP DAT A - CH MODELS.
271846-YTG-B-0208 Johnson Controls Unitary Products 11 T ABLE 8: COOLING PER FORMANCE DA T A - CH 5-10 TON HORIZONT A L MODELS CH060 5 TON 2000 CFM 9 GPM 15 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 10 5°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F 75°F 63.
271846-YTG-B-0208 12 Johnson Controls Unitary Products T ABLE 9: COOLING PER FORMANCE DA T A - CU 5-20 TON VERTICAL MODELS CU060 5 TON 2000 CFM 9 GPM 15 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 105°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F 75°F 62.
271846-YTG-B-0208 Johnson Controls Unitary Products 13 T ABLE 10: COOLING PERFORMANCE DATA - CU 25 TON VERTICAL MODELS T ABLE 1 1: WATER-SIDE ECONOMIZER COOL ING PERFORMANCE DATA - CH 5-10 TON MODELS .
271846-YTG-B-0208 14 Johnson Controls Unitary Products T ABLE 13: STANDARD MOTORS CU 5-25 TON MODELS T ABLE 12: WA TER-SIDE ECONOMIZER CO OLIN G PERFORMA NCE DATA - CU 5-25 TON VERTICAL MODELS UNIT Air @ 80°F EDB, 67°F EWB Wa t e r Capacity [MBH] CFM PD [in WG] Flow [GPM] PD [PSI] EWT [°F] To t a l Sensible CU060 2000 0.
271846-YTG-B-0208 Johnson Controls Unitary Products 15 T ABLE 14: OVERSIZED MOTORS CU 5- 25 TON MODELS T ABLE 15: ST ANDARD MOTORS CH 5-10 TON MODELS T ABLE 16: OVERSIZED MOT ORS CH 8-10 TON MO DEL S MODEL# VOL T AGE COMPRESSOR EV AP ORA TOR F AN MIN.
271846-YTG-B-0208 16 Johnson Controls Unitary Products FIGURE 1 - DIMENSIONAL DATA - CH 5 TON HORIZONTAL MODEL.
271846-YTG-B-0208 Johnson Controls Unitary Products 17 FIGURE 2 - DIMENSIONAL DATA - CH 8 & 10 TON HORIZONTAL MODELS.
271846-YTG-B-0208 18 Johnson Controls Unitary Products FIGURE 3 - PHYSICAL CONFIGURATION DAT A - CH 8 & 10 TON WATER SIDE ECONOMIZER Economizer Coil Filter Frame Electrical Connections 10 12 Water.
271846-YTG-B-0208 Johnson Controls Unitary Products 19 T ABLE 17: DIMENSIONAL D AT A - CU 5, 8, AND 10 TON VERTICAL MODELS FIGURE 4 - DIMENSIONAL DATA - CU 5, 8, AND 10 TON VERTICAL MODELS W A TER OUT W A TER IN CONDENSA TE DRAIN COMPRESSOR/CONDENSER ACCESS G C F 0.
271846-YTG-B-0208 20 Johnson Controls Unitary Products FIGURE 5 - DIMENSIONAL DATA - CU 15 TON VERTICAL MODEL 2.63” 15.88” Allow 36” minimum clearance Allow 24” minimum clearance Allow 24” minimum clearance 18.
271846-YTG-B-0208 Johnson Controls Unitary Products 21 FIGURE 6 - DIMENSIONAL DATA - CU 20 TON VERTICAL MODEL.
271846-YTG-B-0208 22 Johnson Controls Unitary Products FIGURE 7 - DIMENSIONAL DATA - CU 25 TON VERTICAL MODEL.
271846-YTG-B-0208 Johnson Controls Unitary Products 23 SUPPLY AIR/RETURN AIR CONFIGURATION All models are field convertible for multiple supp ly return con - figurations. The 5 throu gh 15 ton model s feature a removabl e upper fan module that can be rotated 180° for top rear dis - charge applications.
271846-YTG-B-0208 24 Johnson Controls Unitary Products FIGURE 9 - HOT W A TER & STEAM HEA TING COILS DIMENSIONAL DA T A Hot W ater and Steam Heating Coil Dimens ions (Inches) Unit Model A B C Inlet (MPT Outle t (MP T) CU060 37.50 5.50 23 1 1/2 1 1/2 CU096 59.
271846-YTG-B-0208 Johnson Controls Unitary Products 25 FIGURE 10 - HOT W A TER & STEAM HE A TING COILS PER FORMANCE DA T A CU240 - 300 CU060 - 180 Steam Coil Performance @ 2 PSIG • S team Heating Coils are tube -in-tube ‘steam distributing ’ typ e to eliminate risk of con- densate freezing.
271846-YTG-B-0208 26 Johnson Controls Unitary Products FIGURE 1 1 - TYPICAL W A TER-SIDE ECONOMIZER PHYSICAL CONFIGURA TION.
271846-YTG-B-0208 Johnson Controls Unitary Products 27 FIGURE 12 - TYPICAL W A TER-S IDE ECONOMIZER PIPING SCHEMA TIC.
Subject to change without notice. Print ed in U. S.A. 271846-YTG-B-0208 Copyright © 2008 by Johnson Controls, Inc. All rights reserved . Supersedes: 271846- YTG-A-0906 Johnson Contro ls Unitary Produ.
An important point after buying a device York CU060 - 300 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought York CU060 - 300 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data York CU060 - 300 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, York CU060 - 300 you will learn all the available features of the product, as well as information on its operation. The information that you get York CU060 - 300 will certainly help you make a decision on the purchase.
If you already are a holder of York CU060 - 300, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime York CU060 - 300.
However, one of the most important roles played by the user manual is to help in solving problems with York CU060 - 300. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device York CU060 - 300 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center