FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 360101-XT G-A-0108 TECHNICAL GUIDE ® DESCRIPTION These packaged cooling air conditi oners are designed for outdoor installation. Only ut i lity and duct connections are required at the point of installation.
360101-XTG-A-0108 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STANDARD FEATURES / BENEFITS . . . . . . . . . . . . . . . . . 1 FIELD-INSTALLED ACCESSORIES . .
360101-XTG-A-0108 Johnson Controls Unitary Products 3 STANDARD FEATURES/BENEFITS (CONT.) UTILITY CONNECTIONS MADE EASY - Electri c al utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor.
360101-XTG-A-0108 4 Johnson Controls Unitary Products operation. Independe nt blade desig n insures p roper control and less than 1% leak rate. Includes hood an d me sh bird screen filter integrated into the ho od, dry bulb senso r and relie f damper.
360101-XTG-A-0108 Johnson Controls Unitary Products 5 SEER = Seasonal Energy Efficiency Ratio - the total coolin g output in BTU's during a normal annual usage period for cooling div ided by the total electric power input in watt-hours dur ing the same period.
360101-XTG-A-0108 6 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 3: COOLING CAP ACITIES - 1 -1/2 T ON (DEB018) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 450 CFM 525 CFM 600 CFM 675 CFM 750 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 18.
360101-XTG-A-0108 Johnson Controls Unitary Products 7 ALL SENSIBLE CAPACITIES T ABLE 4: COOLING CAP ACITIES - 2 T ON (DEB024) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 600 CFM 700 CFM 800 CFM 900 CFM 1,000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 25.
360101-XTG-A-0108 8 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 5: COOLING CAP ACITIES - 2 -1/2 T ON (DEB030) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 750 CFM 875 CFM 1,000 CFM 1,125 CFM 1,250 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 32.
360101-XTG-A-0108 Johnson Controls Unitary Products 9 ALL SENSIBLE CAPACITIES T ABLE 6: COOLING CAP ACITIES - 3 T ON (DEB036) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 900 CFM 1,050 1,200 1,350 1,500 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 34.
360101-XTG-A-0108 10 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 7: COOLING CAP ACITIES - 3 -1/2 T ON (DEB042) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1,050 CFM 1,225 1,400 1,575 1,750 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 40.
360101-XTG-A-0108 Johnson Controls Unitary Products 11 ALL SENSIBLE CAPACITIES T ABLE 8: COOLING CAP ACITIES - 4 T ON (DEB048) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 49.
360101-XTG-A-0108 12 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 9: COOLING CAP ACITIES - 5 T ON (DEB060) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 65.
360101-XTG-A-0108 Johnson Controls Unitary Products 13 Note: 1. D educt these resistance values from t he available external static pressure show n in the respective Blower Performance T able. 2. The pressure thru the economizer is greater for 100 % outdoor air then for 100% return air.
360101-XTG-A-0108 14 Johnson Controls Unitary Products * KW listed is for 240 volts, use tabl e at top of p age for 208 or 230 volts. T ABLE 12: ELECTRICAL DA T A (BASIC UNIT) Model DEB Volt Voltage Limitations 1 1. Rated in accordance with ARI St andard 110, utilization ran ge “A”.
360101-XTG-A-0108 Johnson Controls Unitary Products 15 FIGURE 3 - UNIT DIMENSIONS HIGH VO L TAGE CONN. “ x " DIA. KNOCKOUT 6 DRAIN “ NPTI CONDENS A TE LOW VO L TAGE CONN.
360101-XTG-A-0108 16 Johnson Controls Unitary Products FIGURE 4 - CENTER OF GRAVITY T ABLE 14: UNIT WEIGHTS Unit Size Shipping Weight Operating Weight Corner Weights Economizer (lbs.
360101-XTG-A-0108 Johnson Controls Unitary Products 17 TYPICAL APPLICATIONS FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION FIGURE 6 - TYPICAL ROOF CURB INSTALLATION TO POWER SUPPL Y SUPPL Y AIR DUCT R.
360101-XTG-A-0108 18 Johnson Controls Unitary Products FIGURE 7 - ROOF CURB DIMENSIONS (8 ” Roof curb al so available) FIGURE 8 - ROOF CURB APPLICATION FRONT 1 1 WOOD NAILER 4 INSULA TED P ANELS 22 .
360101-XTG-A-0108 Johnson Controls Unitary Products 19 FIGURE 9 - TYPICAL WIRING DIAGRAM ( 208/230-1-60 POWER SUPPLY) DEB MODEL S 15695BASH0301 SEE DET AIL "A" T2 M1 - 2 DET AIL "A".
360101-XTG-A-0108 20 Johnson Controls Unitary Products MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory-assembl ed, single packaged, Electric Cooling units, desi gned for outdo or mounted installation .
360101-XTG-A-0108 Johnson Controls Unitary Products 21 4. Unit Controls: a. Unit shall contain a large, l ow voltage Te rmi nal Board for easy connection of fi eld low voltage wiring.
360101-XTG-A-0108 22 Johnson Controls Unitary Products.
360101-XTG-A-0108 Johnson Controls Unitary Products 23.
Subject to change without notice. Print ed in U. S.A. 360101-XTG-A-0108 Copyright © 2008 by Johnson Controls, In c. All rights rese rved. Supersedes: 263146-X TG-A-0206/036-21753-0 01-A-0206 Johnson .
An important point after buying a device York AFFINITY 360101-XTG-A-0108 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought York AFFINITY 360101-XTG-A-0108 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data York AFFINITY 360101-XTG-A-0108 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, York AFFINITY 360101-XTG-A-0108 you will learn all the available features of the product, as well as information on its operation. The information that you get York AFFINITY 360101-XTG-A-0108 will certainly help you make a decision on the purchase.
If you already are a holder of York AFFINITY 360101-XTG-A-0108, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime York AFFINITY 360101-XTG-A-0108.
However, one of the most important roles played by the user manual is to help in solving problems with York AFFINITY 360101-XTG-A-0108. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device York AFFINITY 360101-XTG-A-0108 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center