Instruction/ maintenance manual of the product C1000APT Wibur Curtis Company
Go to page of 12
SERVICE MANUAL C1000AP & C1000APT DUAL AIRPOT BREWERS Montebello, California 90640 Telephone 323/837-2300 Fax 323/837-2406 Wilbur Curtis Co.
Inside Front Cover Inside Front Cover 1 1 2 3 3, 4, 5 6, 7 8 9 10 QTY 1 2 1 25 1 ITEM C1000 AP or APT COFFEE BREWER BREW CONE, UNIVERSAL SERVICE MANUAL FIL TER P APER FITTING, 1/4 x 3/8 FLARE ELBOW CAR TON CONTENTS C1000AP & APT ROUGH-IN DRA WING Subject Shipping List .
[ 1 ] C1000AP & C1000APT Airpot Brewer INTRODUCTION This manual applies to Curtis Dual Station Airpot Brewer models C1000AP and C1000APT . Model C1000AP is designed for use with Curtis Airpots CAP-1 thru CAP-5, and other insulated dispensers up to 13¾" tall when opened for filling (see illustration, Step 3 in Coffee Brewing).
2. COFFEE BREWING With a clean filter in place, pour ground coffee into the brew cone. Y ou may need to experiment to determine the cor - rect quantity of ground cof fee for your tastes, but a consistent measure of ground coffee is necessary for controlling the quality of flavor in your brewed coffee.
[ 3 ] CARE AND MAINTENANCE OF C1000 AP Preventive maintenance is essential in keeping your Curtis coffee brewer performing at it's peak. Regular cleaning will pay off with an appealing, high performance, cof fee brewing machine. Preventive Maintenance 1.
When the water level gets below the probe tip, water should automatically refill the tank. If not, pull wire off the probe terminal. W ater should now start flowing into the tank. If not, check the water level control board (see step 4) or inlet valve (step 2).
[ 5 ] TROUBLE SHOOTING CONTINUED: In this coffee brewer there are two elements in parallel. Failure of either will cause very slow heating. Perform the following tests: a. Clamp-on ammeter test: If both elements are good, you will measure about 21 amps at 240 volts or 24 amps at 208 volts.
[ 6 ] ILLUSTRA TED P ARTS BREAKDOWN C1000AP & C1000APT Airpot Brewer.
[ 7 ] ILLUSTRA TED P ARTS BREAKDOWN C1000AP & C1000APT Airpot Brewer 43 42.
[ 8 ] Wilbur Curtis Company , Inc. P ARTS LIST C1000AP & C1000APT Airpot Brewer INDEX Nº P ART Nº WC-5421 WC-1809 WC-1806 WC-3621 WC- 1 14R WC- 122 WC- 202 WC-6324 WC-2936 WC-37237 WC-37265* WC-.
[ 9 ] C1000AP & C1000APT Airpot Brewer.
[ 10 ] WILBUR CURTIS CO., INC. 6913 Acco St., Montebello, CA 90640-5403 USA Phone: 800/421-6150 Fax: 323-837-2410 T echnical Support Phone: 800/995-0417 (M-F 5:30A - 4:00P PST) E-Mail: techsupport@wilburcurtis.
An important point after buying a device Wibur Curtis Company C1000APT (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Wibur Curtis Company C1000APT yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Wibur Curtis Company C1000APT - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Wibur Curtis Company C1000APT you will learn all the available features of the product, as well as information on its operation. The information that you get Wibur Curtis Company C1000APT will certainly help you make a decision on the purchase.
If you already are a holder of Wibur Curtis Company C1000APT, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Wibur Curtis Company C1000APT.
However, one of the most important roles played by the user manual is to help in solving problems with Wibur Curtis Company C1000APT. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Wibur Curtis Company C1000APT along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center