1 Blue 2” Heat Pump Ther mostat Heat Pump or Single Stage Installation and Operating Instructions Save these instructions f or future use! F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMA GE.
2 REMO VE OLD THERMOST A T 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remov e the front cov er of the old thermostat. With wires still attached , remov e wall plate from the w all.
3 INST ALLA TION install fresh “AA” alkaline batteries immediately . For best results, use ne w premium brand alkaline batteries such as Duracell® or Energizer®.
4 WIRING DIA GRAMS L R C SYSTEM MONITOR SWITCH G W2 Figure 4. T ypical wiring diagram for tw o transformer systems with saf ety circuits in BO TH systems Changeov er Relay* Y O/B Compressor Contactor .
5 The confi guration menu allo ws you to set certain ther mostat operating characteristics to your system or personal requirements. T o enter the menu: Set your thermostat to OFF and press the and b uttons simultaneously . The display will show the fi rst item in the confi guration menu.
6 Emergency System EMER bypasses the Heat Pump to use the heat source wired to terminal W2 on the ther mostat. EMER is typically used when compressor operation is not desired, or y ou prefer bac k-up heat only . 1. Mo ve SYSTEM s witch to EMER position, EMER will fl ash on the displa y .
7 Do not allow the compressor to run unless the compressor oil heaters ha ve been operational for 6 hours and the system has not been operational f or at least 5 minutes. CA UTION ! MANU AL OPERA TION • HOLD TEMPERA TURE — With the SYSTEM s witch set to HEA T or COOL , momentarily press R UN/HOLD button.
8 PR OGRAMMING Enter Heating Program 1. Mov e the SYSTEM switch to HEA T . 2. Press PRGM once. “Mo T u We Th Fr” (indicating weekda y program) will appear in the displa y . Also displa yed are the currently programmed start time for the 1st heating period and the currently programmed temper ature (fl ashing).
9 TR OUBLESHOO TING Reset Operation If a voltage spik e or static discharge blanks out the displa y or causes erratic thermostat operation, reset the ther mostat by pressing the , and PRGM buttons sim ultaneously .
10 ST A GING Second Stage - A uxiliary Heat Most heat pump systems hav e an A uxiliar y or Second Stage electric heater or gas fur nace. Heat produced by a heat pump is economical but ma y not alwa ys ha ve the capacity to maintain a comf or table room temperature setting.
11 NO TES.
12 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mar k of Emerson Electric Co. Homeowner Help Line: 1-800-284-2925 www .
An important point after buying a device White Rodgers 1F82-0261 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought White Rodgers 1F82-0261 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data White Rodgers 1F82-0261 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, White Rodgers 1F82-0261 you will learn all the available features of the product, as well as information on its operation. The information that you get White Rodgers 1F82-0261 will certainly help you make a decision on the purchase.
If you already are a holder of White Rodgers 1F82-0261, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime White Rodgers 1F82-0261.
However, one of the most important roles played by the user manual is to help in solving problems with White Rodgers 1F82-0261. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device White Rodgers 1F82-0261 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center