Instruction/ maintenance manual of the product PRO-1200W Whistler
Go to page of 17
OWNER’S MANUAL Pr o-1200W , Pr o-1600W Pr o-2000W , Pr o-2500W Pr o-3000W POWER INVER TERS THE WHISTLER GROUP , INC. CORPORA TE HEADQUAR TERS 3604 N.W . Fr ontage Rd. Bentonville, AR 72712 TEL (479) 273-6012 FX (479) 273-2927 www .whistler gr oup.com CUSTOMER RETURN CENTER 551 N.
1 If you have questions concer ning the operation of this Whistler pr oduct please call customer ser vice: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the r eceipt in a safe place. Y ou may r egister your pr oduct online at www .
WHISTLER FEA TURES A W or d About Whistler Power Inver ters Whistler inver ters convert low voltage, dir ect cur r ent (DC) to 110 volt alter nating household cur r ent (AC). The AC output is called “modified sine wave”. See “T echnical Operating Principles” section for mor e infor mation.
FEA TURES 1. Thr ee 110 AC Outlets 2. Remote Operation Jack The inver ter is designed to be operated fr om a r emote location via a WHISTLER Remote Contr ol Switch (P/N Pro-RS01) which plugs into this socket. This optional accessor y is available thr ough WHISTLER or your WHISTLER dealer .
INVER TER INFORMA TION About Y our New Whistler Inver ter . This manual will pr ovide you with dir ections for the safe and ef ficient operation of your Whistle Power Inver ter . Read the manual car efully befor e using your new Whistler inver ter and keep the manual on file for futur e r efer ence.
power overload. T esting appliances and equipment with star t up load ratings comparable to your inver ter wattage rating will not damage it. If a piece of equipment or an appliance will not operate, first confir m that the inver ter has been pr operly connected to the 12 volt power sour ce (See "Making The Connection").
11 BA TTER Y/CABLE INFORMA TION • It may be advisable to operate the inver ter fr om a bank of batteries of the same type in a "parallel" configuration. T wo such batteries will generate twice the Ah of a single batter y; thr ee batteries will generate thr ee times the Ah and so on.
Pr o- 2000W and Pr o-2500W When the inver ter and the batter y ar e set up within thr ee feet of each other , use a minimum of #2 gauge wire to make the connections. W ithin four to six feet, use a #0 gauge wir e (Pr o-2000W), #00 gauge for Pr o-2500W .
15 14 OPERA TION OPERA TION 7. Confir m that the equipment or appliance to be operated is tur ned of f. Plug the equipment or appliance into one of the AC r eceptacles on the fr ont panel of the the inver ter . 8. T ur n the inver ter to the ON (I) position.
OPERA TION OPERA TION 16 • Check frequently to ensur e that the input and output connections ar e secur e. Loose connections may damage the inver ter , the power sour ce, or may generate excessive heat.
19 18 OPERA TION OPERA TION Some Power ful Advice. When driving with the inver ter in operation, make cer tain that neither the inver ter nor the power cor ds will impede safe operation of your vehicle. Keep the unit and all cor ds clear of the steering wheel, gas, brake and clutch pedals and gear shift.
OPERA TING PRINCIP ALS 21 20 OPERA TION For Y ou T echnical T ypes. 1. Basic Operating Principles: Whistler inver ters work in two stages. During the first stage, the DC to DC conver ter incr eases the DC input voltage fr om the power sour ce (e.g. a 12 volt battery) to 145 volts DC.
OPERA TION SUMMAR Y • In the event of automatic shut down, tur n the inver ter OFF (O) immediately . Do not r estar t the inver ter until the sour ce of the pr oblem has been identified and cor r ected. • T o avoid batter y drain, always disconnect the inver ter when the vehicle is not in use for long periods.
TROUBLESHOOTING 25 PROBLEM: TV Inter fer ence Pr oblem Solution Electrical inter fer ence fr om Add a Fer rite data line filter inver ter . on to the TV power cor d.
SPECIFICA TION Pr o-1200W W A TT INVER TER SPECIFICA TIONS Maximum Continuous Power . . . . . . . . . . . . . . . . . . . . 1200 W atts Maximum Surge Capability (Peak Power) . . . . . . . . . . 2400 W atts No Load Cur r ent Draw . . . . . . . . . . . .
W ARRANTY IMPOR T ANT : Whistler will not assume r esponsibility for loss or damage incur r ed in shipping. Ther efor e, please ship your inver ter insur ed with r etur n r eceipt r equested. 2. Include the following clearly printed infor mation: • Y our name and str eet addr ess (for shipping via UPS), a daytime telephone number , (No P .
MEMO 31 30 W ARRANTY The out of war ranty ser vice fee for the Pr o Series inver ters ar e as follows: Pr o-1200W inver ter is $75.00 Pr o-1600W inver ter is $95.00 Pr o-2000W inver ter is $125.00 Pr o-2500W inver ter is $155.00 Pr o-3000W inver ter is $185.
An important point after buying a device Whistler PRO-1200W (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Whistler PRO-1200W yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Whistler PRO-1200W - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Whistler PRO-1200W you will learn all the available features of the product, as well as information on its operation. The information that you get Whistler PRO-1200W will certainly help you make a decision on the purchase.
If you already are a holder of Whistler PRO-1200W, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Whistler PRO-1200W.
However, one of the most important roles played by the user manual is to help in solving problems with Whistler PRO-1200W. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Whistler PRO-1200W along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center