CONSUMER SER VICES TECHNICAL EDUC A TION GROUP PRESENTS R-103 JOB AID Part No. 8178563 DEHUMIDIFIERS Models: AD25BSS, AD35DSS, AD50DSS Models: AD35USS, AD50USS, AD70USS.
- ii - WHI RL PO OL CO RPO RA TIO N assu me s no re sp ons ib il ity fo r any repai rs ma de on ou r pro du ct s b y any on e oth er th an A uth or ize d Se rvi ce T ec hn ici an s. FOR W ARD This Whirlpool Job Aid, “Dehumidifier” (Part No. 8178563), provides the technician with informa- tion on the operation and service of the Dehumidifier .
- iii - T ABLE OF CONTENTS Page GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Dehumidifier Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- iv - — NOTES —.
1-1 GENERAL DEHUMIDIFIER SAFETY Y our safety and the safety of others are very important. We have provided many important safety messages in this Manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
1-2 MODEL NUMBER AD 50 U S S 0 PRODUCT GROUP AD = Dehumidifier , Whirlpool RD = Dehumidifier , Roper CAP ACITY (24 HR.) 25 Pints 35 Pints 50 Pints 70 Pints MODEL FEA TURES B = Electromechanical, No Deicer , 1 Speed Fan C = Electromechanical, Std. Deicer , 1 Speed Fan D = Electromechanical, Std.
1-3 MODEL & SERIAL NUMBER AND WIRING DIAGRAM LABEL LOCA TIONS Model & Serial Number Label (Behind W ater Bucket) Wiring Diagram Label (Inside Front Half Of Cabinet).
1-4 — NOTES —.
2-1 PRODUCT OPERA TION THEOR Y OF OPERA TION WHA T IS HUMIDITY? Humidity is defined as the amount of water va- por in the air and is measured as a percentage of the amount of water vapor the air can hold at a given temperature.
2-2 OPERA TING CHARACTERISTICS When a dehumidifier begins its run cycle, a partial frosting of the evaporator can be ob - served. This temporary frosting is limited by the operating conditions of the unit. In all cases, the frost should completely disappear within 10 to 15 minutes.
2-3 F AN SPEED: Controls the fan operation, as follows: High: For faster moisture removal Low: For slower moisture removal Auto Fan Speed (Electronic Models): Automatically sets the fan speed based on the relative humidity of the room. Low speed is used when the relative humidity is within 5% of the Desired Humidity setting.
2-4 Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter . Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
2-5 Dryness Control The Dryness Control regulates the amount of moisture in the room. T urn the control knob clockwise for more drying. T urn the control knob counterclockwise for less drying. Turn the control knob to “Dry” to maintain average humidity conditions.
2-6 2. Use front and back handles to lift bucket. Sickness Hazard Do not drink water collected in water bucket. Doing so can result in sickness. Au to —Wil l prov id e th e ma xi mu m hum id - ity control by automatically adjusting the fa n spe ed and / or tur n in g the deh um i di fie r on and off to maintain humidity setting.
2-7 3. Pour water through opening into a sink or tub. 4. Reinstall bucket. IMPORT ANT : If the Empty/Adjust Bucket light comes on, the dehumidifier will not operate. Empty or adjust bucket. Option 2—Connect Drain Hose If you plan to run your dehumidifier continu- ously , you may want to attach a garden hose to the drain hose connector .
2-8 DEHUMIDIFIER CARE CLEANING THE AIR FIL TER (ON SOME MODELS) The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best operating efficiency . Check the filter every 2 weeks to see whether it needs cleaning.
3-1 COMPONENT LOCA TIONS This section instructs you on how to service the Dehumidifier . The components and their loca- tions are shown below . NOTE: The sealed system in the Dehumidifier is not serviced.
3-2 R E M O V I N G T H E CABINET Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unp lu g deh um id ifi er or d is con ne ct po we r .
3-3 6. Remove the bottom screw and the two top hex-head screws from the rear half of the cabinet. 7. Pull the front and rear halves of the cabi - net from the dehumidifier and remove them.
3-4 R E M O V I N G T H E ELECTRONIC CONTROL, THERMIST OR, AND POWER SUPPL Y CORD Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unp lu g deh um id ifi er or d is con ne ct po we r .
3-5 Wire T abs 10. Remove the wiring from the three tabs, and remove the electronic control as - sembly from the dehumidifier . 5. Unclip the thermistor from the tubing and remove it. NOTE: Do not remove the thermistor from the clip. 6. Remove the hex-head screw from the green ground wire.
3-6 R E M O V I N G T H E MECHANICAL HUMIDIST A T , LIGHT , AND POWER SUPPL Y CORD Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unp lu g deh um id ifi er or d is con ne ct po we r .
3-7 8. T o remove the power supply cord: a) Disconnect the white power supply cord wire from the compressor capaci - tor terminal. b) Disconnect the black power supply cord wire from the COM terminal of the bucket switch.
3-8 Fan Capacitor Fan Motor R E M O V I N G T H E F AN CAP ACIT OR AND THE F AN MOTOR Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1.
3-9 c) Remove the three 5/16 ˝ hex-head screws from the fan motor , then pull the wiring out of the access hole and remove the motor . Fan Motor Screws T op g re e n gr o u n d wi r e o n c o n d e ns e r .
3-10 R E M O V I N G T H E COMPRESSOR CAP ACITOR AND THE BUCKET SWITCH Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unp lu g deh um id ifi er or d is con ne ct po we r .
3-1 1 4. T o remove the bucket switch: Electronic Model: a) Disconnect the two black wires from the N.C. and COM switch terminals. Mechanical Models: b) Disconnect the black (COM), tan (N.O.), and yellow (N.C.) wires from the switch terminals. Bucket Switch BK (COM) BK (N.
3-12 — NOTES —.
4-1 COMPONENT TESTING Refer to page 3-6 for the procedure for ac- cessing the mechanical humidistat. 1. Unp lu g deh um id ifi er or d is con ne ct po we r . 2. Disconnect the two wires from the hu- midistat terminals. 3. T urn the humidistat control fully counter- clockwise.
4-2 Refer to page 3-8 for the procedure for ac- cessing the fan motor . 1. Unp lu g deh um id ifi er or d is con ne ct po we r . 2. IMP OR T ANT : Dis ch ar ge the cap aci to r by tou ch in g th e l ea ds of a 20 ,0 00 ohm re si s - tor t o the c ap aci to r t er mi nal s.
5-1 DIAGNOSTICS & TROUBLESHOOTING DIAGNOSTICS Step T est LED Na me LED Cond iti on 1 LEDs All All illuminate 2a Bucket switch Bucket Blinking = Bucket removed (switch open) ON soli d = Bucke t ins.
5-2 PROBLEM CAUSE CORRECTION Unit will not run - no fan and no compressor . 1. Unit not turned “ON” or not set dry enough. 1. Set control to “CONTINUOUS.” This will allow the fan and com- pressor to run regardless of the ambient humidity . 2. No power to unit.
6-1 WIRING DIAGRAM 1 WIRING DIAGRAMS.
6-2 WIRING DIAGRAM 2.
6-3 WIRING DIAGRAM 3.
6-4 — NOTES —.
6-5 — NOTES —.
6-6 — NOTES —.
PRODUCT SPECIFICA TIONS AND W ARRANTY INFORMA TION SOURCES IN THE UNITED ST A TES: FOR PRODUCT SPECIFICA TIONS AND W ARANTY INFORMA TION CALL: F O R T E CH NI CA L AS S I S T AN CE W H I L E A T T H E.
CO R P O R A T I O N.
An important point after buying a device Whirlpool AD35DSS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Whirlpool AD35DSS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Whirlpool AD35DSS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Whirlpool AD35DSS you will learn all the available features of the product, as well as information on its operation. The information that you get Whirlpool AD35DSS will certainly help you make a decision on the purchase.
If you already are a holder of Whirlpool AD35DSS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Whirlpool AD35DSS.
However, one of the most important roles played by the user manual is to help in solving problems with Whirlpool AD35DSS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Whirlpool AD35DSS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center