Instruction/ maintenance manual of the product 800062000-Brn-PO Rie BF5 Weil-McLain
Go to page of 19
Install ation & O perating M anual C 6501073(0) S i n g l e s t a g e o p er a ti o n oil burners RETROFIT APPLICATIONS ONLY If this burn er is being instal led in a packaged un it (ie.
3398 GB INSTALLLATION PRECAUTIONS AIR FOR COMBUSTION Do not instal l burner in room with insuffic ient air for combust ion. Be sure there is an adequate air suppl y for combustion if the boil er room is enclosed. It may be nec es sary to create a window t o permit sufficient air to enter the boile r room.
3398 GB TABLE OF CONTENTS PACKAGE CONTENTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SERIAL NUMBER IDEN TIFICATION . . . . . . . . . . . . . . . .
3398 1 GB PACKAGE CONTENTS LIST Your Riel lo 40 BF b urner shoul d include the follow ing parts. Pl ease che ck to make s ure all pa rts are pre sent before be - ginnin g the in stallati on.
3398 2 GB TEC HNI CAL DA TA SPECIFICATIONS BU R N E R AND MOUNTING FLANGE D IM E N S IO N S BURNER COMPONENTS IDENTIFICATION Fuel No. 2 Fuel O il BF3 Firing rate - Effective Output 0.50 to 0. 95 US GPH - 70,0 00 to 133, 000 BTU/h BF5 Firing rate - Effective Output 0.
3398 3 GB MOUNTING THE BURNER TO THE BOILER - Positi on the MOUNT ING G ASKE T (2) be - tween the flat sur face of the UNIVERS AL MOUNTING FLAN GE (1) install ed on the burner and the appli ance.
3398 4 GB APPLICATION FIELD WIRING Oi l V a l v e Cap a c i t o r GR EEN BLU E BLAC K BLACK WH I T E BLUE M BR OW N AL 100 9- 1 B ur ner F an- Of f Ti m e r 6 12 8 N 1 11 9 3 2 7 Co nt r o l B o x 530.
3398 5 GB INSTALLATION/REMOVAL OF DRAWER ASSEMBLY Removal: A) Remove th e air press ure switch support (6) fro m the fron t shield by the two ret ain- ing screws (7) B) Loosen o ff oil delivery tube n ut from pump. C) Loosen SCREW ( 3), and th en unplug CONT ROL BO X (1) by carefu lly pu lling it back a nd then up.
3398 6 GB OIL LINE CONNECTIONS This burne r is s hipped wit h the oil p ump set to operate o n a single line sy stem. To ope rate on a two-line sy stem the by -pass pl ug must be inst alled. NOTE: Pump pressure must be set at time of b urner start- up.
3398 7 GB NPTF - NPT pipe adapter The B F bu rner you ha ve pu rchas ed is s hipped with an NP TF to NPT fi tting. This fitting is the connec tion point for the oil line from the oil tank or the in-line oil filter. In some locations, fit- tings wi th the NPT F male thread are difficul t to obtain.
3398 8 GB PUMP PURGE NOTE: To protect the pump gear s, it is advisabl e to lubricate the pump prior to purging a lift system. Apply oil through the VACUUM PORT (C). A) SIN GLE LINE (GRA VITY FE ED SYSTE M) I. Loosen the bleeder valve (A) until oil flows out.
3398 9 GB COMBUST ION CHAMBER PRESSURE CHA RT BURNER OUTPUT VS CHA MBER PRESSURE CHA RT D7525 (GPH) BURNER OUTPUT CHAM BER P RESSUR E (INCHES WC) 0 .0 0.
3398 10 GB BURNER START-UP CYC LE Normal Lock- out, due to l ight-failu re Thermo stat Motor Igniti on transf ormer Va l v e Flame Lock-o ut lamp ~ 12 se c.
3398 11 GB TROUBLE SHOOTING CHART • Faulty CAD cell or seeing light before trial for ignition. • Coil wire on terminals #1 & 2 or #1 & 8 reversed. • Open coil circuit, terminals #2 & 8. • Open coil circuit, terminal #1 (530 SE only).
3398 12 GB A TYPICAL LA YOUT FOR BF BURNER INT AKE AIR A) Use an approve d air in take kit. B) Al ways keep i ntake air run to the m inimum. C) Max imum intake air run of 4 ( inch) diam eter , flex ible or rigid type of venting = 100í D) Reduc e intake air l ength by 10’ for ever y 90° el bow used.
13 3398 EXPLODED SPARE PARTS LIST.
14 3398 SPARE PARTS LIS T No. CODE DESCRIPTION No. CODE DESCRIPTION 1 3008019 • BURN ER BAC K COVER 1 C8111015 • B URNER BA CK COVER 2 3007077 • • CRUSHABLE MET AL WASHER 3/8” ID 3 3007568 .
3398 15 GB BURNER START- UP FORM * 35 Pond P ark Rd. Hingham, MA 02043 Phone: 78 1-749-8 292 T oll Free: 800-992 -7637 Fax: 78 1-740-2069 2165 Meado wpine Blv d. Mississau ga,On L5H 3R2 Phone: 9 05-542- 0303 T oll Free: 800-387-38 98 Fax: 9 05-542-152 5 Burner S/N.
T echnical Supp ort Hotline 1-80 0-4- RIELLO 1-800-474 -3556 35 Pond Park Ro ad Hingham, MA 020 43 Phone 781-7 49-8292 T oll Free 800-992-76 37 Fax 781-7 40-2069 www .riello u sa. com 2165 Meado wpine Blv d Mississ auga, ON L 5N 6H6 Phone 905-5 42-0303 T o ll Free 80 0-387-3898 Fax 905-5 42-1525 www .
An important point after buying a device Weil-McLain 800062000-Brn-PO Rie BF5 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Weil-McLain 800062000-Brn-PO Rie BF5 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Weil-McLain 800062000-Brn-PO Rie BF5 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Weil-McLain 800062000-Brn-PO Rie BF5 you will learn all the available features of the product, as well as information on its operation. The information that you get Weil-McLain 800062000-Brn-PO Rie BF5 will certainly help you make a decision on the purchase.
If you already are a holder of Weil-McLain 800062000-Brn-PO Rie BF5, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Weil-McLain 800062000-Brn-PO Rie BF5.
However, one of the most important roles played by the user manual is to help in solving problems with Weil-McLain 800062000-Brn-PO Rie BF5. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Weil-McLain 800062000-Brn-PO Rie BF5 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center