© 2010 WA YNE Pumps 353502-001 3/10 24-V olt Backup Sump Pump OPERA TING INSTRUCTIONS AND P AR TS MANUAL PLEASE READ AND SA VE THESE INSTRUCTIONS. READ CAREFULL Y BEFORE A TTEMPTING TO ASSEMBLE, INST ALL, OPERA TE OR MAINT AIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMA TION.
2 Operating Instructions and Parts Manual www .waynepumps.com A ground fault cir cuit interrupter is required. This pump must only be used to pump clear water . This pump is not designed to handle effl uent, salt water , brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials.
3 Model ESP45 www .waynepumps.com PUMP INST ALLA TION Installation of this unit may take several hours. Before disabling your main pump, have ready an appr opriate means of evacuating the sump. 1. T urn power to main pump off. 2. Pump must be installed using 11/4” or 11/2” rigid PVC piping.
4 Operating Instructions and Parts Manual www .waynepumps.com W ear safety goggles when connecting batteries. Battery connections should be made in a well-ventilated area. 1. Place battery box within six feet of the sump and a 115 V AC separately fused outlet.
5 Model ESP45 OPERA TION Always disconnect the power source befor e attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor , water or discharge piping when pump is connected to electrical power . Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water .
6 Operating Instructions and Parts Manual TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump won't run 1. Connections not secure 2. Low or defective battery 3. Float switch stuck 4. Defective or blown fuse 1. Check all connections 2.
7 Model ESP45 www .waynepumps.com FOR REPLACEMENT P ARTS OR TECHNICAL ASSIST ANCE, CALL 1-800-237-0987 Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: WA YNE Water Systems 101 Production Drive Harrison, OH 45030 U.
8 Operating Instructions and Parts Manual www .waynepumps.com LIMITED WARRANTY For one year from the date of purchase, WA YNE Pumps ("WA YNE") will repair or re place, at its option, for the.
9 Fr © 2010 WA YNE Pumps 353602-001 3/10 MÉMENTO : Gardez votre pr euve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. Pompe de vidange de secours 24 volts INSTRUCTIONS D'UTILISA TION ET MANUAL DE PIÉCES PLEASE READ AND SAVE THESE INSTRUCTIONS.
Instructions d‘Utilisation et Manual de Pièces 10 Fr Un interrup-teur pour protéger contr e un défaut de mise à la terre (DDFT) est exigé. Cette pompe est conçue pour le pompage de l’eau claire seulement.
Modèle ESP45 11 Fr • Le CB/AC est conçu seulement pour la pompe de WA YNE Water Systems, il NE doit P AS être utilisé à toutes autres fins. LE SYSTÈME P ASSERA À L'ALARME SI: • On entend un bip d'alarme si le moteur de la pompe fonctionne.
Instructions d‘Utilisation et Manual de Pièces 12 Fr minimum car cela réduit l’écoulement de sortie de la pompe. Le tuyau qui sort de la structure de l’édifi ce devrait être en pente vers le bas pour que l’eau ne gèle pas dans le tuyau.
Modèle ESP45 13 Fr T oujours débrancher le c.a. et retir er le fusible de la pompe avant de brancher ou débrancher la batterie. 1. Choisir un emplacement convenable sur le plancher près du puisard, pour placer le boîtier de batterie. S'assurer que le cordon du CB/AC atteigne le courant c.
Instructions d‘Utilisation et Manual de Pièces 14 Fr GUIDE DE DÉP ANNAGE Symptôme Cause(s) Possible(s) Mesures Corr ectives Pompe ne fonctionne pas 1. Raccords ne sont pas sûrs 2. Batterie faible ou défectueuse 3. Interrupteur à fl otteur coincé 4.
Modèle ESP45 15 Fr POUR DES PIÈCES DE RECHANGE, COMPOSER 1-800-237-0987 S’il vous plaìt fournir l’information suivante : - Numéro de modèle - Numéro de série (si applicable) - Description et numéro de pièce d’après la liste de pièces Correspondance : WA YNE Pumps 101 Production Drive Harrison, OH 45030 U.
Instructions d‘Utilisation et Manual de Pièces 16 Fr GARANTIE LIMITÉE For one year from the date of purchase, WA YNE Pumps ("WA YNE") will repair or re place, at its option, for the orig.
17 Sp © 2010 WA YNE Pumps 353602-001 3/10 MÉMENTO : Gardez votre pr euve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. Bomba de r espaldo para sumider os MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PIEZAS POR F A VOR LEA Y GUARDE EST AS INSTRUCCIONES.
Manual de Instrucciones de Operación y Piezas 18 Sp Esta bomba sólo debe usarse para bombear aguas limpias. Esta bomba no está diseñada para bombear efl uentes, agua salada, salmuera,agua con detergentes o en ningún otro líquido que contenga químicos causticos y/o residuos y partículas.
Modelo ESP45 19 Sp BOMBA: • La bomba se encenderá cuando el interruptor de flotador se eleve. El motor de la bomba continuará funcionando durante 15 segundos después de que baje el flotador . INST ALACIÓN DE BOMBA La instala-ción de esta bomba podría tomarle varias horas.
Manual de Instrucciones de Operación y Piezas 20 Sp MÉTODO 2 Si no es posible lograr una descarga separada y dedicada como en el Método 1, la bomba ESP45 puede conectarse a la tubería de descarga de la bomba que funciona con CA, instalando un conector "Y".
Modelo ESP45 21 Sp ¡Riesgo de choque eléctrico! Use un interruptor de circuito de descarga a tierra (GFCI) para reducir el riesgo de choque eléctrico mortal. Asegúrese de que la conexión a tierra del receptáculo esté graduada para 5 amp. por lo menos.
22 Sp GUÍA DE DIAGNÓSTICO DE A VERÍAS Problema Posible(s) Causa(s) Acción Correctiva La bomba no funciona 1. Conexiones fl ojas 2. Batería baja o defectuosa 3. Interruptor de fl otador atascado 4. Fusible defectuoso o quemado 1. Revise todas las conexiones 2.
Modelo ESP45 23 Sp N°. de Ref. Descripción Númer o de pieza Ctd. 1 Bomba 06710 1 2 PS/BC (suministro de energía/carga- dor de batería) 30260-002 1 3 Impulsor 29884-001 1 4 Anillo de desgaste 2818.
Manual de Instrucciones de Operación y Piezas GARANTÍA LIMIT ADA Durante un año a partir de la fecha de compra del comprador original, la compañía WA YNE Pumps ("WA YNE") reparará o re.
An important point after buying a device Wayne ESP45 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Wayne ESP45 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Wayne ESP45 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Wayne ESP45 you will learn all the available features of the product, as well as information on its operation. The information that you get Wayne ESP45 will certainly help you make a decision on the purchase.
If you already are a holder of Wayne ESP45, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Wayne ESP45.
However, one of the most important roles played by the user manual is to help in solving problems with Wayne ESP45. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Wayne ESP45 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center