Instruction/ maintenance manual of the product E65-NG1 Waterford Appliances
Go to page of 40
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
2 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove W A TERFORD EMERALD Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Waterford Direct Vent Freestanding Gas Stove by Waterford Irish Stoves.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 3 T ABLE OF CONTENTS Page Page Support Extension - Round or Square ....................... 22 Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System ....................
4 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove This is a copy of the label that accompanies each EMERALD Direct Vent Freestanding Gas Stove. We have printed a copy of the contents SAFETY LABEL here for your review. The safety label is located on the inside of the drop down pedestal door.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 5 SAFETY LABEL Copy of Safety Label for E65-LP1 Propane Stove For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.
6 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove IMPORT ANT : SA VE THESE INSTRUCTIONS The EMERALD Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 7 INST ALLA TION pages 11 and 12 for the required vent arrangements. If installed into a manufac- tured home the unit must be bolted down to the floor. 4) This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat.
8 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove OPTIONAL F AN INST ALLA TION Diagram 1 Diagram 2 INST ALLA TION LOCA TING YOUR EMERALD GAS STOVE When selecting a location for your stove, en- sure that the clearances listed above are met as well as ensuring that there is adequate acces- sibility for servicing and proper operation.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 9 INST ALLA TION PRECAUTIONS These venting systems are engineered prod- ucts that have been designed and tested for use with the E65-NG1, and E65-LP1 .
10 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove INST ALLA TION EXTERIOR VENT TERMINAL LOCA TIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(min.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 11 INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI.
12 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Horizontal Venting RIGID PIPE VENTING - HORIZONT AL TERMINA TIONS The shaded area in the diagram below shows all allowable combinations of vertical runs with horizontal terminations.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 13 INST ALLA TION RIGID PIPE VENTING - VERTICAL TERMINA TIONS FOR BOTH RESIDENTIAL & MANUF ACTURED HOMES/MOBILE HOMES The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations.
14 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove VERTICAL TERMINA TION WITH CO-LINEAR FLEX SYSTEM This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the Venting Arrangements chart below for minimum and maximum flue lengths.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 15 INST ALLA TION DV ST OVE HORIZONT AL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the E65 Direct Vent unit with minimum horizontal and vertical vent dimensions.
16 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove DV ST OVE HORIZONT AL VENT KIT (# 946-1 16 & #946-216) INST ALLA TION Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wall thick- ness.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 17 INST ALLA TION DURA-VENT TERMINA TION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent Direct Vent System installations: horizontal termina- tion and vertical termination.
18 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove You will require the following components with your new Emerald Direct Vent Freestanding Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 19 Note: a) The horizontal run of vent should have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.
20 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Diagram 9 DURA-VENT VERTICAL TERMINA TION Diagram 7 Diagram 8 3) To install the Round Support Box/Wall Thim- ble in a flat ceiling, cut a 10 inch square hole in the ceiling centred on the hole drilled in Step 2.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 21 CA THEDRAL CEILINGS Round Support (RDS) & Square Support (SQS) If your home has a cathedral ceiling (no attic space between the ceiling and the roof), install the chimney and support as follows.
22 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove INST ALLA TION Diagram 3 Diagram 4 Diagram 5 4) Pass the flex pipe down through the center of the chimney system, and center the adaptor on the top of the chimney pipe. Drill four 1/8" diameter holes through the adap- tor and into the chimney top.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 23 Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq.
24 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. HIGH ELEV A TION This unit (with 38,000 Btu) is approved in Can- ada for altitude 2000 ft.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 25 4) Carefully remove the logs, embers and rockwool. 5) Remove burner. See diagram below. Pilot assembly is now accessible for steps 6) to 11). Note: Use a magnetic type screwdriver if possible.
26 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove REDUCTION KIT TO LOWER BTU RA TING FOR E65-1 GAS STOVE 3) Open the front door. Open the right side door and there is a cutout in the heat shield through which can be seen a wing nut threaded on to a stud attached to the front door.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 27 OPTIONAL DOOR GRILL INST ALLA TION Door Grill Kit Contains: Qty. Description 1 Front Door Grill 4 Screws 4 Grill Clips 1) Open the front door.
28 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 29 OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
30 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove Copy of the Lighting Plate instructions OPERA TING INSTRUCTIONS pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob. 4) When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" posi- tion.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 31 8) Each time the appliance is lit, it may cause condensation and fog the glass. This con- densation and fog is normal and will disap- pear in a few minutes as the glass heats up. Never operate the appliance without the glass properly secured in place or with the door open.
32 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the rear access panel on the back of the unit. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 33 11) Carefully lift the burner tray assembly out. REMOVING VAL VE If your valve requires maintenance or replace- ment, use the following instructions: Note: Always close off the gas supply before removing the valve.
34 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove PARTS LIST MAIN ASSEMBL Y 1) W400141** Emerald Right Door (Black) 2) 904-258 Door Magnet 3) 948-134 Door Stop 4) 44351 Black Butt Hinge 5).
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 35 BURNER & LOG ASSEMBL Y 52) 910-190 Piezo Ignitor & Nut 56) 908-672 Control Panel Decal 57) 490-061 Switch Plate 910-896 High Temperature Wire Harness - to Power Cord 261-574/P Valve Assembly S.
36 Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove _____________________________________________________________________________________ ____________________________________________________.
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove 37 _____________________________________________________________________________________ ____________________________________________________.
_____________________________________________________________________________________ ____________________________________________________________ _____________________________________________________.
W ARRANTY Waterford Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd.
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ .
An important point after buying a device Waterford Appliances E65-NG1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Waterford Appliances E65-NG1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Waterford Appliances E65-NG1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Waterford Appliances E65-NG1 you will learn all the available features of the product, as well as information on its operation. The information that you get Waterford Appliances E65-NG1 will certainly help you make a decision on the purchase.
If you already are a holder of Waterford Appliances E65-NG1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Waterford Appliances E65-NG1.
However, one of the most important roles played by the user manual is to help in solving problems with Waterford Appliances E65-NG1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Waterford Appliances E65-NG1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center