Instruction/ maintenance manual of the product WLS 9500 Wasp Bar Code
Go to page of 22
QUICK ST ART GUIDE W asp WLS 9500 www .waspbarcode.com.
Quick Start Guide 1 CORD A TT ACHMENT Scan Windo w Tr i g g er LED Beeper Interface cable modular connector To h o s t Cable interface Interface cable modular connector clip Model Number and Serial Number appear here.
Quick Start Guide 2 SCANNER PROGRAMMING BARCODES Reset Def aults Set All Defaults Set Postamble Note: If you do not need a Postamble, scan 1 Erase All Rules.
Quick Start Guide 3 HOST INTERF ACES Note: Cable may vary depending on configuration. SCANNER PROGRAMMING BARCODES S tart Here if you have a USB scanner: *HID Keyboard Emulation USB OPOS Handheld S tart Here if you have a keyb oard wedge scanner .
Quick Start Guide 4 TROUBLESHOOTING Scanner not wor ki ng Scanner not dec odi ng bar code No power to scann er Inc o rrec t int erf ace cabl e used I nter face/ power cabl es are l oose Scanner not pr.
Quick Start Guide 5 SYMBOLOGIES This section provides the fo llowing information: Enable/Disable Barcodes - Thes e barcod es allow you to enable o r disable sym bologies. Check Digit Barcodes - The check digit is th e last character of the symbol used to verify the integrity of the data.
Quick Start Guide 6 Enable/Disable UPC-E1 Enable/Disable EAN-13/EAN-8 Enable UPC-E1 * Disable UPC-E1 * Enable EAN-13 Disable EAN-13 * Enable EAN-8 Disable EAN-8.
Quick Start Guide 7 Enable/Disable Bookland EAN Transmit UPC-A Check Digit Enable Bookland EAN * Disable Bookland EAN * T ransmit UPC-A Check Digit Do Not T ransmit UPC-A Check Digit.
Quick Start Guide 8 Transmit UPC-E1 Check Digit . UPC-A Preamble * T ransmit UPC-E1 Check Digit Do Not T ransmit UPC-E1 Check Digit No Preamble (<DA T A>) * System Character (<SYSTEM CHARACTE.
Quick Start Guide 9 UPC-E Preamble UPC-E1 Preamble No Preamble (<DA T A>) * System Character (<SYSTEM CHARACTER> <DA T A>) System Character & Country Code (< COUNTR Y CODE>.
Quick Start Guide 10 Convert UPC-E to UPC-A Enable this to convert UPC-E ( zero suppressed) de coded dat a to UPC-A format before tran smission. After conversion, the data follows U PC- A format and is affected by UPC-A programming selections (e .g., Preamble, Check Digit).
Quick Start Guide 11 EAN-8/JAN-8 Extend When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. When disabled, EAN-8 symbols are transmi tted as is . Code 128 Enable/Disable Code 128 .
Quick Start Guide 12 Enable/Disable ISBT 128 ISBT 128 is a variant of Code 128 used in the blood ba nk i ndustry . Scan the appropriate bar code below to enable or disable ISBT 128.
Quick Start Guide 13 T rioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously . Trans mit Code 39 Check Digit Code 39 Check Digit V erification must be enable d for this para meter to function. Convert Code 3 9 to Code 32 Code 32 is a vari ant of Code 39 used by the Italian pharma ceu tical industry .
Quick Start Guide 14 Code 32 Prefix Code 93 Enable/Disable Code 93 Enable Code 32 Prefix * Disabl e Code 32 Prefi x Enable Code 93 * Disabl e Code 93.
Quick Start Guide 15 Code 1 1 Enable/Disable Code 1 1 . Interleaved 2 of 5 (ITF) Enable/Disable Interleaved 2 of 5 Due to the construction of the I 2 of 5 symbology , it is possible for a scan line covering on ly a portion of th e code to be in terpreted as a complete scan, yielding less data than is encoded in the bar code.
Quick Start Guide 16 Discrete 2 of 5 (DTF) Enable/Disable Di screte 2 of 5 Codabar (NW - 7) Enable/Disable Codabar Enable Discrete 2 of 5 * Disable Discrete 2 of 5 Enable Codabar * Disabl e Codabar.
Quick Start Guide 17 RSS (Reduced S p ace Symbology) The variant s of RSS are RSS 14, RSS Expand ed and RSS Limite d. RSS 14 and RSS Expanded inclu de stacked versions.
Quick Start Guide 18 SAMPLE BARCODES Code 39 UPC/EAN UPC-A, 100% EAN-13, 100% Code 128 123ABC 0 1 2 3 4 5 6 7 8 9 0 5 3 4 5 6 7 8 9 0 1 2 3 4 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 .
Quick Start Guide 19 Interleaved 2 of 5 RSS 10293847560192837465019283746029478450366523 (RSS Expanded S tacked) 1234890hjio9900mnb (RSS Expanded) 08672345650916 (RSS Limited) 123456789012 3.
Quick Start Guide 20 RSS-14 55432198673467 (RSS-14 T runcated) 90876523412674 (RSS-14 S t acked) 7812346570981 1 (RSS-14 S tacked Omni-Directional).
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful inter- ference in a residential installation.
An important point after buying a device Wasp Bar Code WLS 9500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Wasp Bar Code WLS 9500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Wasp Bar Code WLS 9500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Wasp Bar Code WLS 9500 you will learn all the available features of the product, as well as information on its operation. The information that you get Wasp Bar Code WLS 9500 will certainly help you make a decision on the purchase.
If you already are a holder of Wasp Bar Code WLS 9500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Wasp Bar Code WLS 9500.
However, one of the most important roles played by the user manual is to help in solving problems with Wasp Bar Code WLS 9500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Wasp Bar Code WLS 9500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center