ITW Food Equipment Group, LLC 3600 North Point Blvd. Baltimore, MD 21222 RETAIN THIS MANUAL FOR FUTURE USE FORM F36950 (05-08 ) INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers MODELS MLS VACB20 ML-135285 VACB25 ML-710543 VACB36 ML-710544 VACB47 ML-710545 VACB60 ML-710546 VACB72 ML-135286 www.
- 2 - IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GA S EQUIPMENT , WHO SHOU LD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED .
- 3 - INSTALLATION, OPERATION AND CARE OF GAS COUNTERTOP CHARBROILERS GENERAL Gas Countertop C harbroilers are designed for commer cial use only and feat ure fast, efficient ga s heat. Eac h burner is controlle d by an adj ustable gas valve. Cas t radiant s are located dire ctly above each burner to maint ain uniform temperat ure.
- 4 - supply connecti on(s). Provide 24" clea rance at the fron t for cleaning, mai ntenance, service and proper operation. Minimum clea rances to co mbustible construc tion are 1 2" to the back and 9 " to the si des. Minimum clea rances to non-c ombustible walls are 0" to th e rear and 0" to the sides.
- 5 - LEVELING It is important that the charbro iler is level front to back and lef t to right. Areas of unev en heat distribut ion will occur on an unlevele d unit. The charb roiler is equipp ed with adjustable legs. Turn the feet at t he bottom of the le gs to a djust to le vel.
- 6 - GAS PRESSURE REGULATO R INSTALLATION Gas regulator p ressure is preset at 5 ” Water Column (W.C.) for natural gas, and 10” W.C. for propane gas. Mino r adjust ments may be required b ased on site specific ga s pressure. Install the reg ulator as close to t he broiler on t he gas supply l ine as possibl e.
- 7 - Fig. 2 All orifices are of the fixed type and require no adjus tment. Standing pilots should be adjusted to provide a sl igh t yellow tip on the fla me. Pilots may be lighted by remo ving adjacent cast iron top grates and radiants. Air shutters on the main burners must b e individually adjusted to provide a blue flame.
- 8 - COMPONENT PARTS The Achiever Ch arbroiler comes with severa l standard par ts as illus trated. Each can b e easily removed and insta lled easily by hand for cleaning and maintenance. Note that the Burner and Deflector are an assembly an d are NOT designed to be disassembled.
- 9 - ACCESSORIES STANDS The charbro iler has an optiona l 24” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide stainless st eel stand with casters or flanged legs. T he front c asters lock, and flanged legs may be bolte d to the floor.
An important point after buying a device Vulcan-Hart ACB47 ML-710545 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vulcan-Hart ACB47 ML-710545 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vulcan-Hart ACB47 ML-710545 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vulcan-Hart ACB47 ML-710545 you will learn all the available features of the product, as well as information on its operation. The information that you get Vulcan-Hart ACB47 ML-710545 will certainly help you make a decision on the purchase.
If you already are a holder of Vulcan-Hart ACB47 ML-710545, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vulcan-Hart ACB47 ML-710545.
However, one of the most important roles played by the user manual is to help in solving problems with Vulcan-Hart ACB47 ML-710545. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vulcan-Hart ACB47 ML-710545 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center