Instruction/ maintenance manual of the product WINE-MATE VINO1500HZD Vinotemp
Go to page of 24
WINE-MATE Cooling Unit Use & Care Manual VINO1500HZD VINO2500HZD VINO3500HZD VINO4500HZD VINO6500HZD VINO8500HZD V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p . . w w w w w w . . v v i i n n o o t t e e m m p p .
- 1 - Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 OR 30 AMPCIRCUIT IS REQUIRED (1500-4500HZD OR 6500-8500HZD).
- 2 - TABLE OF CONTENTS Features & Specifications.…………………….……………..3 Installation Instruction………………………………………..5 Temperature Control & Humidity Adjustment...………..13 Care Guide…………………………………………………… .
- 3 - Features and Specifications • HZD cooling unit is designed and us ed to provide a stable temperature between 50~65 ° F for suitable space at a normal environment. • The refrigerated space will mainta in humidity of 50~70% RH even when the environment becomes dry and humid.
- 4 - Fig. 1.2 DIMENSIONS The dimension and capacity are specified as follows: MODEL CFM CAPACITY cu ft (55 ° F/75 ° F) DIMENSIONS W”XD”XH” ELECTRICAL WEIGHT (lb) VINO-1500HZD 120 90 14.25X16X13.25 115V/60HZ/4A 50 VINO-2500HZD 180 200 14.25X16X13.
- 5 - Installation Instruction Select a place to mount the unit where t he exhaust airflow is unobstructed for a minimum of 6 inch. The area into which t he unit exhausts must be well ventilated. If it is not, heat exhaust ed by the unit will build up and the unit will not operate properly.
- 6 - • If top exhaust, place another gaskets al ong the top exhaust at the top of the cooling unit (see Fig.2.3). • Move the cooling unit towards the m ounting sides and push to press the gaskets (see Fig 2.5). • Fasten the 2 brackets and use 7/16” wrench to tighten t he two ¼” screws (see Fig 2.
- 7 - Fig. 2.2 GASKET Fig. 2.3 TOP EXHAUST GASKET.
- 8 - Fig. 2.4 THREAD INSERT Fig. 2.5 COOLING UNIT.
- 9 - Fig. 2.6 FASTENING BRACKET & SCREW.
- 10 - Fig. 2.7 CABINET GRILLE 2. VINO3500-8500HZD THROUGH WALL INSTALLATION • Cut a rectangular opening at the win e room wall as illustrated. The dimensions of the opening shall be 1/4” larger than the width and height of the unit.
- 11 - • Attach the molding to the wall not the unit. • Plug the unit into a properly gr ounded and dedicated outlet of adequate capacity. Fig. 2.8 THROUGH WALL INSTALLATION Fig.
- 12 - 3. Cellar Construction This is only a guide and shall be c onsidered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
- 13 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature.
- 14 - 2.1 LED Functions LED MODE FUNCTION ON Compressor enabled Flashing Anti-short cycle enabled ON Defrost cycle enabled ON Fan enabled Flashing Fan delay after defrost enabled ON Alarm occurring ON Temperature measuring unit Flashing Programming mode 3) Alarm Signals 3.
- 15 - 5) Parameter Programming 1. Press the SET + keys for 3 sec until the “ °C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + keys for more th an 7sec until the Pr2 label will be displayed, then release the keys.
- 16 - Care Guide 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Coil is on the ambient air intake side of the cooling unit.
- 17 - Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Complaint Possible Causes Response 1. Unit not running a. Power cord unplugged b.
- 18 - l. Failed components l. Check comp ressor windings, sta rt relay and overload protector 5. Unit running too long a. Improper room insulation & seal b. Exhaust restricted c. Room too large d. Ambient temperature higher > 90 ° F e. Dir ty C ondenser a.
- 19 - 11. Evaporator freezing up a. Evaporator air flow restricti on b. Not stopping due to air leak, high ambient temperature or low setting c. Low ambient temperature d. Bad thermostat or sensor e. Moisture in the system f. Refrigerant low or le aking g.
- 20 - Wiring Diagram Fig. 6.1 VINO1500-2500H ZD Wiring Diagram Fig. 6.3 VINO3500-8500H ZD Wiring Diagram.
- 21 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.
- 22 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model____________________ ____________________ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual.
- 23 - is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
An important point after buying a device Vinotemp WINE-MATE VINO1500HZD (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vinotemp WINE-MATE VINO1500HZD yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vinotemp WINE-MATE VINO1500HZD - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vinotemp WINE-MATE VINO1500HZD you will learn all the available features of the product, as well as information on its operation. The information that you get Vinotemp WINE-MATE VINO1500HZD will certainly help you make a decision on the purchase.
If you already are a holder of Vinotemp WINE-MATE VINO1500HZD, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vinotemp WINE-MATE VINO1500HZD.
However, one of the most important roles played by the user manual is to help in solving problems with Vinotemp WINE-MATE VINO1500HZD. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vinotemp WINE-MATE VINO1500HZD along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center