Instruction/ maintenance manual of the product VINO8500HZD Vinotemp
Go to page of 25
WINE-MATE Cooling Unit Use & Care Manual VINO1500HZD VINO2500HZD VINO3500HZD VINO4500HZD VINO6500HZD VINO8500HZD V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p . . w w w w w w . . w w i i n n e e m m a a t t e e .
- 1 - Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 15 OR 20 AMPCIRCUI T IS HIGHLY RECOMMENDED.
- 2 - TABLE OF CONTENTS Feature Description…………………………….……………..3 Installation Instruction………………………………………..5 Temperature Control & Humidity Adjustment...………..13 Care Guide…………………………………………………… .
- 3 - Feature Description • HZD cooling unit is designed and us ed to provide a stable temperature between 50~65 ° F for suitable space at a normal environment. • The refrigerated space will mainta in humidity of 50~70% RH even when the environment becomes dry and humid.
- 4 - • See the voltage, frequency and current from the label on the back or side of the cooling unit. The dimension and capacity are specified as follows: MODEL COOLING CAPACITY, CFM 55 ° F/75 ° F BOTTLE CAPACITY 55 ° F/75 ° F DIMENSIONS IN. WXHXD ELECTRICAL WEIGHT (lb) VINO- 1500HZD 1500 Btu/h, 120 CFM 150 cu ft 800 bottles 14.
- 5 - Installation Instruction Select a place to mount the unit where t he exhaust airflow is unobstructed for a minimum of 6 inch. The area into which t he unit exhausts must be well ventilated. If it is not, heat exhaust ed by the unit will build up and the unit will not operate properly.
- 6 - Fig. 2.2 GASKET Fig. 2.3 TOP EXHAUST GASKET.
- 7 - Fig. 2.4 THREAD INSERT Fig. 2.5 COOLING UNIT.
- 8 - Fig. 2.6 FASTENING BRACKET & SCREW.
- 9 - Fig. 2.7 CABINET GRILLE • Cut a rectangular inside opening with the 1/4” clearance inwards to the width and height of the cooling unit. By not going through, leave 1/2” lip inside at the wall to place t he gaskets (see Fig 2.
- 10 - • Plug the cooling unit in receptacle. • Plug the wine cellar. 2. VINO3500-8500HZD ROOM INSTALLATION 1. Cut a rectangular opening at the wine room wall as illustrated. The dimensions of the opening shall be 1/4” larger than the width and height of the unit.
- 11 - Fig. 2.9 TOP EXHAUST GASKET 3. Cellar Construction This is only a guide and shall be c onsidered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
- 12 - large amounts of moisture. When placed into operation in this type of environment, the system will work harder to re move this extra moisture resulting in increased “run” time. 4. Electrical Cord Because of potential safety hazards under a certain condition we strongly recommend against the use of an extension co rd.
- 13 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature.
- 14 - 2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds afte r the fault in the re lated probe; they automatically stop a few seconds afte r the probe restarts normal operation. Check connections before replacing the probe.
- 15 - 2. The value of the set point will be di splayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the keys or arrows within 10s. 4. To memorize the new set point value, push the SET key again or wait 10s. 4) Humidity Adjustment The parameter Fon is used to adjust the humidity in the wine cabinet.
- 16 - Care Guide 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Coil is on the ambient air intake side of the cooling unit.
- 17 - Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a.
- 18 - 6. “HA” alarm blinking and beeping, temperature high or not cooling and running continually a. Improper room insulation & seal b. Room too large c. Ambient temperature too high d. Exhaust restricted e. Malfunctioning fans f. Improper evaporator or condenser airflow g.
- 19 - f. Refrigerant low or leaki ng g. Capillary tube blockage f. Check for current and sealed system leakage g. Check fo r low side pressure 11.Water leak a. High humidity b. Air leak in wine cellar c. Evaporator air flow restriction d. Water passages restricted e.
- 20 - Wiring Diagram Fig. 6.1 VINO1500-2500H ZD Wiring Diagram Fig. 6.2 VINO1500-2500HZD CALLI NG FEATURE WIRING DIAGRAM.
- 21 - Fig. 6.3 VINO3500-8500H ZD Wiring Diagram Fig. 6.4 VINO3500-8500HZD Ca ll Feature Wiring Diagram.
- 22 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.
- 23 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model_____________ _________________________ __ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual.
- 24 - is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
An important point after buying a device Vinotemp VINO8500HZD (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vinotemp VINO8500HZD yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vinotemp VINO8500HZD - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vinotemp VINO8500HZD you will learn all the available features of the product, as well as information on its operation. The information that you get Vinotemp VINO8500HZD will certainly help you make a decision on the purchase.
If you already are a holder of Vinotemp VINO8500HZD, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vinotemp VINO8500HZD.
However, one of the most important roles played by the user manual is to help in solving problems with Vinotemp VINO8500HZD. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vinotemp VINO8500HZD along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center