Instruction/ maintenance manual of the product F20470I EN Viking
Go to page of 24
F20470I EN (082012) Viking Installation Guide Pr ofessional & Outdoor Hoods Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product infor mation, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.
T able of Contents 3 IMPORT ANT– Please Read and Follow! NOTE: If installing hood with warming shelf panel, install war ming shelf panel first. IMPORT ANT – PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully .
5 IMPORT ANT– Please Read and Follow! 4 W A R N I N G TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS Rangehoods must be installed with the ventilators that are specified on their carton indicating suitability with this model. Other ventilators cannot be substituted.
6 Clearance Dimensions 7 Interior V entilator Dimensions 460 CFM Interior V entilator Installation T op View (VWH 10”H. W all Hoods w/Standard V entilator) (VWH 10”H.
9 Dimensions & Specifications 8 ( VW H 18 ” H . 2 4 ” De e p W al l Ho o ds 3 0 ”, 3 6” , 42 ” , 48 ” , 54 ” , & 6 0” ) ( VW H 18 ” H . 2 7 ” De e p W al l Ho o ds 3 6 ”, 4 8” , & 6 0 ”) * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Exterior V entilator Dimensions 11 Interior V entilator Dimensions 10 900 or 1200 CFM Exterior or In-Line V entilator Installation for all W all Hoods 1200 or 1500 CFM Exterior or In-Line V entilator .
13 12 Dimensions & Specifications ( VW H O 18 ” H. O u td o o r W al l Ho o ds 3 6” , 4 8” , & 6 0 ”) * A 1,200 CFM interior- or exterior-power ventilator should be used with all T -Series models and when i ndoor models are installed over range/rangetop with gas char -grill.
15 Dimensions & Specifications 14 (VCWH Chimney W all Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”) * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft.
Interior V entilator Dimensions 16 Exterior V entilator Dimensions 17 900 or 1200 CFM Exterior or In-Line V entilator Installation for 30”, 36”, & 42” models 900, 1200 or 1500 CFM Exterior o.
19 Dimensions & Specifications 18 (DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”) * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.
21 20 Exterior V entilator Dimensions Interior V entilator Dimensions 300 or 600 CFM Interior V entilator Installation for 30”, 36”, & 42”Hoods 900 or 1200 CFM Exterior or In-Line V entilato.
23 22 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft. ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
Exterior V entilator Dimensions 25 Interior V entilator Dimensions 24 900 or 1200 CFM Exterior or In-Li ne V entilator Installation for all Chimney Island Hoods 900, 1200 or 1500 CFM Exterior or In-Li.
27 26 Dimensions & Specifications (VBCV W all Custom V entilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”) * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
29 Built-In W all Custom V entilator System Dimensions (VBCV Models ) For 900, 1200 or 1500 CFM Exterior or In-Line V entilator Installation For 300, 600 or 1200 CFM Interior V entilator Installation 900 or 1200 CFM Exterior or In-Line V entilator Installation 30”, 36”, 42” W .
31 30 1200 or 1500 CFM Exterior or In-Line V entilator Installation 48”, 54”, 60”, 66” W . Models 1200 CFM Interior V entilator Installation 30”, 36”, 42”, 48”, 54”, 60”, 66” W . Models Built-In W all Custom V entilator System Dimensions (VBCV Models ) C 30” W .
33 CAUTION: If not using a duct cover , using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary . Connect black to black, white to white, and the green/bar e wire under the green screw .
35 CAUTION: Secure vent hood. Make sure mounting screws are secured into framing. Use additional mounting screws and wall anchors, if necessary . Remove electrical box cover . Flip hood over . Insert 6” of electrical wiring through the top of vent hood and secure.
37 Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (provided locally) to wall using screws provided. Use additional mounting screws to secure hood to wood strip. Installation (VWH 18”H. W all & VCWH Chimney W all Hoods) CAUTION: Secure vent hood to wall using screws provided.
39 Pl ac e du ct co ve r t op i ns id e d uc t c ov e r b as e a nd lo we r un ti l de si r ed h ei gh t i s f ou nd . Ma rk he ig ht . U s e t he r et ai ni ng nu ts a nd bo lt s t o f as t en in pl ac e a nd r em o ve ta pe . Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.
41 Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape. Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct does not stick down past the cover . Slide filter front over front lip. Push filter rear up, then slide back over rear lip.
43 42 Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (not included) to wall using screws provided. Use additional mounting screws to secure hood to wood strip.
44 Service & Registration Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referr ed to a qualified technician.
47 46.
An important point after buying a device Viking F20470I EN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Viking F20470I EN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Viking F20470I EN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Viking F20470I EN you will learn all the available features of the product, as well as information on its operation. The information that you get Viking F20470I EN will certainly help you make a decision on the purchase.
If you already are a holder of Viking F20470I EN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Viking F20470I EN.
However, one of the most important roles played by the user manual is to help in solving problems with Viking F20470I EN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Viking F20470I EN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center