Instruction/ maintenance manual of the product R18CFL Vermont Casting
Go to page of 14
— Do not store gasoline or other flammable vapors or liquids near this or any other appliance. — WHA T T O DO IF Y OU SMELL GAS • Do not try to light any appliance. • Do not touch an y electrical switch; do not use any phone in y our building.
2 20003889 Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read these directions thoroughly before installation. For assistance or additional infor- mation, consult your gas log dealer , qualified installer , service agency or gas supplier .
20003889 3 The Logsets have been designed and tested to operate safely when installed according to the installation instructions contained in this manual. Read all instructions before starting the installation. • The logset should be inspected before use and at least annually thereafter .
4 20003889 CA UTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Are you burning Natural Gas? If you have Propane Gas, you need to purchase a factory authorized safety pilot kit (see below).
20003889 5 This Damper Stop is designed to work on all CFM Specialty Home Products BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6. When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close completely .
6 20003889 The Damper Stop provided keeps your damper from accidentally closing during operation of your set. This Damper Stop must be installed onto your Damper at all times . NOTE: The damper clamp is designed to hold the damper plate open 3 inches.
20003889 7 Leak T est Pr ocedures Create a mixture of equal parts soap and water . Apply to all the joints of the pipe fittings from the gas supply pipe to the burner . T urn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak.
8 20003889 1. Place the Elevated Grate Steps onto the back of the Grate and attach the Fettel to front of Grate as shown in Figure 7. 2. Place the Grate over the Burner Pan so the front legs of the Grate are 1” behind the front edge of the Pan, as shown in Figure 8.
20003889 9 1. T urn the gas shut-of f valve to OFF . 2. W ait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information above. If you don’t smell gas, go on to the next step. 3. Light a match and lay it on top of the pan material, about 2” from the end of the supply side of the pan.
10 20003889 Tr oub leshooting Log Set is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flame contacts the logs.
20003889 11 8 11 7 5 4 2 3 17 13 18 16 14 19 10 12 15 9 6 1 a b c d e f g h CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. R18 / 24 / 30CFL V ented Gas Logs 1.
12 20003889 R18 / 24 / 30CFL V ented Gas Logs (continued) Ref. Description R18CFL R24CFL R30CFL 11 . Cast Front Grate w/Clips CIGF18 CIGF24 CIGF30 12. Grate 20000924 20000925 20000926 13. Grate Step 20000955 20000955 20000955 14. Pan & Extension Assembly 20003840 20003841 20003842 15.
20003889 13 W ARRANTIES OF MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W ARRANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EX- PRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Pr oducts.
An important point after buying a device Vermont Casting R18CFL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vermont Casting R18CFL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vermont Casting R18CFL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vermont Casting R18CFL you will learn all the available features of the product, as well as information on its operation. The information that you get Vermont Casting R18CFL will certainly help you make a decision on the purchase.
If you already are a holder of Vermont Casting R18CFL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vermont Casting R18CFL.
However, one of the most important roles played by the user manual is to help in solving problems with Vermont Casting R18CFL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vermont Casting R18CFL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center