Instruction/ maintenance manual of the product IRFSDV24 Vermont Casting
Go to page of 28
1 Irving Oil 10004000 Installation Instructions and Homeowner ’ s Manual INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Freestanding Direct V ent Fireplaces IRFSDV24 IRFSDV34 10004000 0102 Rev .
2 Irving Oil 10004000 Installation Instructions ................................................................................................................ 3 Important Curing/Burn Information ......................................................
3 Irving Oil 10004000 A - *Flat on wall B - *Room divider C - Island D - Cross corner E - Flat on wall corner * A & B must maintain a 12” (305 mm) clearance between the wall and side glass of fireplace. There is a minimum vertical rise required for the venting which varies depending on the application.
4 Irving Oil 10004000 IRFSDV24 IRFSDV34 A 23 in (584 mm) A 26-14 in (667 mm) B 28-3/4 in (730 mm) B 31-1/2 in (800 mm) C 16-5/8 in (422 mm) C 19-3/8 in (492 mm) D 27-3/8 in (695 mm) D 30 in (762 mm) E.
5 Irving Oil 10004000 Max. Max. Input Input Model Fuel Gas Control BT U/h BT U/h IRFSDV24RN Nat Millivolt Hi/Lo 20,000 14,000 IRFSDV24RP Prop Millivolt Hi/Lo 20,000 1 5,000 IRFSDV34RFN Nat Radio Frequency 30,0 00 21,000 IRFSDV34RFP Prop Radio Frequency 30,000 22,500 Natural LP (Propane) Input Minimum 5.
6 Irving Oil 10004000 The remote ON/OFF switch can not be fitted to units using the Honeywell Radio Frequency control valve. If the fireplace has been fitted with the Radio Frequency Control Valve, the ON/OFF function is controlled by the remote handset.
7 Irving Oil 10004000 Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12 inches (30cm) 12 inches (30 cm) deck, or balcony B = Clearance to window/door that may be op.
8 Irving Oil 10004000 584-15 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.
9 Irving Oil 10004000 Before joining elbows and pipes apply a bead of high temperature sealant to the crimped end of the elbow or pipe. Join the pipes using a 2” (50mm) overlap and secure the joints with three (3) sheet metal screws (Fig. 11). Wipe off excess sealant.
10 Irving Oil 10004000 VERTICAL SIDEWALL APPLICATIONS Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.
11 Irving Oil 10004000 Horizontal Dimension From The Outside Face Of The Wall To The Center Of The Fireplace Vent Flange Vertical Dimension From The Floor Of The Fireplace To The Center Of The Horizontal Vent Pipe TO USE THE VENT GRAPH SIDEWALL VENTING GRAPH ( Dimensions In Feet) 1.
12 Irving Oil 10004000 STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size (Fig. 17). (For combustible walls first frame in opening.
13 Irving Oil 10004000 When it is not possible to meet the required vent terminal clearances of 12 inches (305mm) above grade level a snorkel vent kit is recommended. It allows installation depth of down to 7 “ (178mm) below grade level. The 7 “ is measured from the center of the horizontal vent pipe as it penetrates through the wall.
14 Irving Oil 10004000 If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as protruding wall face (Fig.
15 Irving Oil 10004000 installations. From 0 to a maximum of 8’ of vent pipe can be used between elbows (Fig. 25). • 7DVCS must be used to support offsets (Fig. 26). This application will require that you first determine the roof pitch and use the appropriate starter kit.
16 Irving Oil 10004000 CRIMPED END VENTING COMPONENTS Starter Kit-Model 7FSDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B orde.
17 Irving Oil 10004000 Starter Kit - Model 7TFSMSK Starter Kit-Model 7TFSDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B or.
18 Irving Oil 10004000 Only glass approved by the Vermont Castings, Majestic Products Company may be used for replacement. 1. Shut off gas (See Lighting Instructions). 2. Let the unit cool if it has been operating. 3. Open two side doors 4. Open the clamps on two sides.
19 Irving Oil 10004000 1. It is important to keep the burner and the burner compartment clean. This must be done periodically, at least once per season (See Cleaning Procedure). 2. Clean the brass trim using a soft clean cloth, slightly dampened with lemon oil and buff with a soft clean cloth.
20 Irving Oil 10004000 RN/RP Models For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ knob located near the center of the gas control valve (See Fig. below). It is important to periodically perform a visual check of the pilot and burner flames.
21 Irving Oil 10004000 OPTIONAL GOLD TRIM KIT OPTIONAL FRAME WINDOW TRIM KITS A decorative gold plated window trim kit Model #VT1G00 RFSDV24TKG is available for the IRSFD24 Freestanding Fireplace. The kit contains: 1 Gold-plated Window Trim 4 Magnets INSTALLATION PROCEDURE 1.
22 Irving Oil 10004000 1. STOP! Read the safety information above on this page. 2. Turn off all electrical power to the fireplace appliance. 3. For MN/MP/TN/TP appliances only, go on to Step 4. for RN/RP turn the On/Off switch to “OFF” position or set thermostat to lowest level.
23 Irving Oil 10004000 OPERATING INSTRUCTIONS FOR RFN/RFP COMFORT CONTROL VALVE Mode Auto On/Off Countdown Timer Fan Display Room Temperature Set Temperature Flame Height Level Fan Speed Level Countdo.
24 Irving Oil 10004000 FAN Antenna Red White Red White Pilot Assembly Valve (Bottom View) Fan Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key .
25 Irving Oil 10004000 TROUBLE SHOOTING THE GAS CONTROL SYSTEM Set manual s witch to local or remote Light pilot burner Five min ute wait period Did the LED stop blinking? No Re view LED f ailure analysis Release pilotstat knob T ur n pilotstat knob from PILO T to ON Cycle s witch once and leav e in remote.
26 Irving Oil 10004000 Code # Part Description IRFSDV24 IRFSDV34 1 Log Set Complete 10003538 100001763 1a Log ember bed --- KR7 1b Log - Front left KR13 KR8 1c Log - Front right KR14 KR9 1d Log - Rear.
27 Irving Oil 10004000 Code# Part Description IRFSDV24 IRFSDV34 20 Fan Assembly with bracket 54103 54103 21 Remote ON/OFF Switch 53606 53606 22* Wiring Harness - Remote Switch 57265 57265 23* Remote O.
28 Irving Oil 10004000 REPLACEMENT PARTS L O H I PILOT ADJ PILOT ON OFF 1c 1b 1g 1h 3 14 18c/d 20 37 21 24 27 28 29 30 32 9c/d 11a 10 13b 8a/b 11a 13a 14 11b 39 13b 17 15 O N P I L O T O F F 14 18a/b .
An important point after buying a device Vermont Casting IRFSDV24 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vermont Casting IRFSDV24 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vermont Casting IRFSDV24 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vermont Casting IRFSDV24 you will learn all the available features of the product, as well as information on its operation. The information that you get Vermont Casting IRFSDV24 will certainly help you make a decision on the purchase.
If you already are a holder of Vermont Casting IRFSDV24, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vermont Casting IRFSDV24.
However, one of the most important roles played by the user manual is to help in solving problems with Vermont Casting IRFSDV24. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vermont Casting IRFSDV24 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center