Instruction/ maintenance manual of the product DTV38s2 Vermont Casting
Go to page of 48
Installation Instructions and Homeowner ’ s Manual W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Please read the installation & operating instructions before using this appliance. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 This gas fireplace should be installed by a qualified installer , preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber .
5 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Y D A B C E Y X LU584 Locating unit DVT38S2 3/17/04 djt Locating Y our Fireplace LU584-1 Fig. 2 Locate gas fireplace. A) Flat on wall B) **Island C) *Room divider D) *Flat on wall corner E) Chase installation Y) 6” minimum Note (Fig.
6 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 T op of Unit to Ceiling ................................ 36” (914 mm) Front of Unit to Combustibles (both sides) 36” (914 mm) Appliance T op Standoffs ............................................
7 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. The hearth cannot exceed 1 ¹⁄₂ ” (38 mm) in height from bottom of fireplace for ease of door accessibility .
8 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Gas Inlet and Manifold Pressures Natural LP (Propane) Minimum Inlet Pressure 5.5” w .c. 1 1.0” w .c. Maximum Inlet Pressure 14.0” w .c. 14.0” w .c. Manifold Pressure 3.5” w .c. 10.0” w .c.
9 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Control System The gas control system is located on the right hand side of the firebox behind an access panel and the decora- tive brick panel. The fireplace is operated using only the hand held remote control unit.
10 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 19.If you choose to install the optional wireless wall mounted remote control (Part No. 20012267), install two (2) button batteries provided with the remote control by removing four (4) screws holding the back cover in place.
1 1 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Hand-Held Remote Control T ransmitter Operating Instructions Introduction This transmitter operating range is approximately 20 feet (6 m).
12 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 FP1820 F-C display.
13 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 FP1821 set temp 9/07 T o Change the Set T emperature Press and hold the SET key until the desired set tem- perature is reached.
14 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Operational Notes: The Thermostatic feature on the transmitter operates the appliance whenever the ROOM TEMPERA TURE varies a certain number of degrees from the SET TEMPERA TURE. This variation is called the “SWING” or TEMPERA TURE DIFFERENTIAL.
15 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Pilot Main AF-4000 DC Motor Red Black White or Green Green or White Orange or White Black Brown Red Orange Main Module Black Gnd Brown Brown Black .
16 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
17 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Outside Corner Inside Corner T ermination Clearances T ermination clearances for buildings with combustible and noncombustible exteriors.
18 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Horizontal T ermination The vent must rise vertically a minimum of 24” (610 mm) off the top of the unit, before the first elbow . The horizontal run may extend up to 20’ (6 m) and include a vertical rise of up to 40’ (12 m).
19 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 When the vent termination exits through foundations less than 20” (508 mm) below siding outcrop, the vent pipe must be flush with the siding.
20 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 STEP 2 Measure wall thickness and cut zero clearance sleeve parts to proper length (MAXIMUM 12”/305 mm). As- semble sleeve using #8 sheet metal screws (supplied). (Fig. 20) Install firestop assembly .
21 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 FP1458 Fig. 23 Through the wall. FP1457 Fig. 22 Horizontal length requirement. X FP1460 Fig. 24 Secure termination to wall. Support horizontal pipes every 3’ (914 mm) with metal pipe straps. Check fireplace to make sure it is levelled and properly positioned.
22 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 FP1461 thru wall trim 3/17/04 djt 2” (51mm) 1” (25mm) Min. 1” (25mm) Min. 16 ¹⁄₄ ” x 16 ¹⁄₄ ” (413 x 413mm) Opening FP1461 Fig. 25 A 2” (51mm) thick trim is required around opening.
23 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 V ertical Through-the-Roof Applications Use of Restrictor Plate for V ertical V enting Application The primary purpose for the vent restrictor is to regain flame height under certain venting conditions as outlined below .
24 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 plicable. When using the unitized 30°, 45° or 90° elbows, apply 1/4” bead of high temperature, 550°F or higher , sealant (milpack or stove cement) to the joint of the inner pipe (flue pipe) and the straight section as it is impossi- ble to be taped.
25 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 This Gas Fireplace has been approved for , • V ertical installations up to 40’ (12 m) in height. Up to a 20’ (6 m) horizontal vent run can be installed within the vent system using a maximum of three (3) 90° elbows.
26 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 FP593 SR/C 11/20/97 Attic Installation Ceiling Installation Nails (4) Firestop Spacer Joist Joist Firestop Spacer Nails (4) FP593 Fig. 36 Installing firestop spacer . FP263 MBUF 5/9/96 Attic Insulation Shield Ceiling Base Flanges Nails (4 Re- quired) Attic Joist FP263 Fig.
27 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Chimney Components Horizontal Starter Kit Contains 24”-40” telescopic pipe* for minimum vertical SK8DVSK rise from collar pipe, 90° elbow , horizontal through-wall starter pipe, zero clearance sleeve, metal adhesive tape, sidewall termination and firestop.
28 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Only glass approved by CFM Corporation should be used on this fireplace. 1. T urn the fireplace OFF (including the pilot). 2. If the unit has been operating allow time for the components to cool. 3.
29 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 firebox. T ilt it carefully toward the side until the piece is in place. Using the two (2) brackets and four (4) screws provided with the refractory kit, fasten each bracket to the top of the firebox on each side.
30 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 1. Ensure the four (4) screws that attach the fettle to the burner are secure. 2. Set the andirons in place by hooking the tabs on the back of the andirons over the webs of the fettle. (Fig. 43) Repeat process for and- irons on both sides of burner .
31 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 6. Position the log burner overlay . (Fig. 46) The overlay is very fragile and must be handled with extra care. Hold the overlay with the flat surface facing down. The notched corners of the overlay should be on the side of the pilot.
32 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Log Right Grate (F49) Figure 49 LG504 10. Position the log right grate. (Fig. 49) Hold the log with your right hand with the pointed end toward the left and the flat surface facing down.
33 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 It is important to periodically perform a visual check of the pilot and burner flames. Compare them to Figures 52. If the flame patterns appear abnormal contact a qualified service provider for service and adjustment.
34 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 T rim Installation CAUTION: Allow fireplace to cool if it has been in operation. T rim components: 2 each, top frame assembly , bottom trim assembly , right and left trim assem - blies.
35 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Lighting & Operating Instructions For Fireplaces equipped with American Flame Automatic Control System (IN or IP) A. This fireplace is equipped with an ignition device which automatically lights the pilot and main burner .
36 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 T roubleshooting If erratic system behavior is observed that cannot be resolved by the methods outlined below , ensure that there is not a transmitter with batteries installed that may be interfering.
37 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 T roubleshooting American Flame Gas Control System (continued) Pilot is burning, but ignitor continues to spark • Check that flame sensor is fully inpinged by pilot flame. If not, adjust pilot. • Check end-to-end continuity of sensor .
38 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 American Flame Gas Control System Error Codes Ignition Safety: Protection for Ignition System Error Code: One beep every one second Description of Fault: W arn users if the pilot is not successfully ignited in 60 seconds.
39 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having ju- risdictio n.
40 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 CO134 AF pilot orifice 3/07 Index T ab Snap Ring Allen Wrench CO134 Fig. 57 Remove pilot orifice. 1. Remove two (2) screws holding the pilot assembly to the burner assembly . Move the pilot assembly toward the back wall.
41 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 22. Turn on gas supply and operate valve with remote control as needed to indicate gas pressure. The manifold pressure for LP should be approximately 10.0” wcp. CAUTION: T urn off the valve and gas supply before removing test port adaptor and replac- ing plug.
42 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
43 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
44 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 DVT38S2 (continued) Ref. Description DVT38S2 1. Log Set (Complete) 2001 1955 1a. Log Overlay F56 20012883 1b. Log Right Grate F49 (2 per fireplace) 2001 1980 1c. Log Pilot Plumbing F50 2001 1981 1d.
45 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 DVT38S2 (continued) Ref. Description DVT38S2 26. T rim Kit Complete (2 per fireplace) 20010894 26a. T op T rim (2 per fireplace) 20010901 26b. Right Side T rim (2 per fireplace) 20010902 26c. Left Side T rim (2 per fireplace) 20010903 26d.
46 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 Accessories Back-up Battery Kit All Models: DVTBBK Follow instructions provided with the kit and on Page 9 for installation. W all Mountable Wireless Remote T ransmitter All Models: Part # 20012267.
47 Chateau™ Dir ect V ent Gas Fir eplace 2001 1957 LIMITED LIFETIME W ARRANTY CFM Corporation (hereinafter referred to as CFM) warrants that all cast iron parts, the combustion chamber , ceramic bur.
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) DVT38S2IN 47.1 DVT38S2IP 47.1 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .
An important point after buying a device Vermont Casting DTV38s2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vermont Casting DTV38s2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vermont Casting DTV38s2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vermont Casting DTV38s2 you will learn all the available features of the product, as well as information on its operation. The information that you get Vermont Casting DTV38s2 will certainly help you make a decision on the purchase.
If you already are a holder of Vermont Casting DTV38s2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vermont Casting DTV38s2.
However, one of the most important roles played by the user manual is to help in solving problems with Vermont Casting DTV38s2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vermont Casting DTV38s2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center