Instruction/ maintenance manual of the product 2477 Vermont Casting
Go to page of 32
DO NOT DISCARD THIS MANUAL: Retain for future use 30002314 10/06 Rev . 9 2278 Dutchwest noncat cover 5/04 Homeowner ’ s Installation and Operating Manual If this heater is not properly installed, operated, and maintained, a house fire may result.
2 Dutchwest Non-Catal ytic Con vection Heater 30002314 The Dutchwest Model 2477 covered in this Owner ’ s Guide has been tested and listed by OMNI - T est Laboratories, Inc. of Beaverton, Oregon. The test stan- dards utilized were UL 1482 for the United States and ULC S-627 for Canada.
3 Dutchwest Non-Catal ytic Con vection Heater 30002314 1. Maximum burn times and heat outputs are based on laboratory testing using full loads of seasoned hardwoods, and may vary in individual use depending on how the stove is operated, type and moisture content of fuels, and other factors.
4 Dutchwest Non-Catal ytic Con vection Heater 30002314 Installation SAFETY NOTICE: IF YOUR DUTCHWEST CON- VECTION HEA TER IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T . FOR SAFETY , FOLLOW ALL INST ALLA- TION, OPERA TION AND MAINTENANCE DIREC- TIONS.
5 Dutchwest Non-Catal ytic Con vection Heater 30002314 Prefabricated Chimneys A prefabricated metal chimney must be one tested and listed for use with solid-fuel burning appliances. A horizontal connector run should be inclined 1/4” per foot (20 mm per meter) from the stove toward the chimney .
6 Dutchwest Non-Catal ytic Con vection Heater 30002314 Double-W all Connector Information on assembling and installing double-wall connectors is provided by the manufacturer of the double-wall pipe. Follow the manufacturer ’ s installation instructions exactly .
7 Dutchwest Non-Catal ytic Con vection Heater 30002314 Securing the Connector to a Masonry Chimney The Dutchwest Convection heater may be connected to either a freestanding masonry chimney or a masonry fireplace chimney .
8 Dutchwest Non-Catal ytic Con vection Heater 30002314 Fireplace Installations - Through the Fireplace The Convection heater may be installed either without legs* as a fireplace insert, or with standard legs at- tached - depending on the safety regulations that apply to your situation, the height of the fireplace opening and your own preference.
9 Dutchwest Non-Catal ytic Con vection Heater 30002314 Floor Protection A tremendous amount of heat radiates from the bottom plate of your Dutchwest stove. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox.
10 Dutchwest Non-Catal ytic Con vection Heater 30002314 Procedure: 1. Convert specifications to R-value: i. R-value given - no conversion needed. ii. k-factor is given with a required thickness (T) in inches: iii. K-factor is given with a required thickness (T) in inches: iv .
1 1 Dutchwest Non-Catal ytic Con vection Heater 30002314 S M TT T ST800 fireplace install Keep the Stove a Safe Distance From Surrounding Materials Both a stove and its chimney connector radiate heat in all directions when operating.
12 Dutchwest Non-Catal ytic Con vection Heater 30002314 Alcove Installations Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations.
13 Dutchwest Non-Catal ytic Con vection Heater 30002314 Designing a Safe Installation The section that follows contains charts with the infor- mation that you’ll need to make your installation safe.
14 Dutchwest Non-Catal ytic Con vection Heater 30002314 Corner Corner Parallel Installations Installations Parallel Installations Installations Stove and Chimney Connector Clearance Charts Stove Clear.
15 Dutchwest Non-Catal ytic Con vection Heater 30002314 Distance from Center of Flue Collar to W all in T op-Exit Installations Dutchwest Convection Heater Model 2477 NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue col- lar will be for various installations.
16 Dutchwest Non-Catal ytic Con vection Heater 30002314 W all Heat Shield Dimensions DutchWest Non-Catalytic Convection Heater Model #2477 ST802 sidewall protection 5/04 48” (1220mm) 48” (1220mm) Spaced 1” (25mm) from Floor ST802 Fig. 22 Sidewall protection.
17 Dutchwest Non-Catal ytic Con vection Heater 30002314 Y our convection heater requires some assembly . Follow the directions carefully and refer to the parts diagram at the back of this manual. Unpack the Parts Remove the bottom heat shield strapped to the top of the stove and all loose parts from the firebox and the ash pan.
18 Dutchwest Non-Catal ytic Con vection Heater 30002314 6. Reposition the stove so the other front corner over- hangs the pallet and remove the leg bolt from the bottom of the stove. Align the leg with the bolt hole in the bottom of the stove, and attach it with the bolt and washer .
19 Dutchwest Non-Catal ytic Con vection Heater 30002314 Heater Controls and Features Air Control The Dutchwest Convection Heater Model 2477 has a control that regulates the amount of air drawn into the stove.
20 Dutchwest Non-Catal ytic Con vection Heater 30002314 Successful Wood Burning Woodburning is often said to be more of an art than a science. Y ou’ll easily master the art if you start by using good, dry fuel and by understanding how the stove’s air supply system operates.
21 Dutchwest Non-Catal ytic Con vection Heater 30002314 Use the Air Control Settings that Work Best for Y ou No single control setting will fit every situation. Each installation will differ depending on the quality of the fuel, the amount of heat desired, and how long you wish the fire to burn.
22 Dutchwest Non-Catal ytic Con vection Heater 30002314 Y ou’ll soon find that this stove is HOT WHILE IN OPER- A TION! KEEP CHILDREN, CLOTHING, AND FURNI- TURE A W A Y . CONT ACT MA Y CAUSE SKIN BURNS. DO NOT OVERFIRE THIS HEA TER. Overfiring may cause a house fire, or can result in permanent damage to the stove.
23 Dutchwest Non-Catal ytic Con vection Heater 30002314 Remove Ashes Frequently Wear heavy stove gloves when removing ashes. Check the ash compartment before reloading the stove. If the ash pan is nearly full, empty the pan. Before replacing the ash pan, clear away any ash that may have spilled over the sides and back of the pan.
24 Dutchwest Non-Catal ytic Con vection Heater 30002314 Keep Y our Stove Looking New And Working Its Best Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Dutchwest Convection Heater looking new .
25 Dutchwest Non-Catal ytic Con vection Heater 30002314 3. Apply a thin bead of stove cement in the newly- cleaned groove. 4. Lay the gasket into the groove. Wait until you are a couple inches from the end before you cut it. 5. T est the gasket by closing the door on a slip of paper as described above.
26 Dutchwest Non-Catal ytic Con vection Heater 30002314 Cleaning the Chimney System The chimney system is composed of the chimney and the pipe that connects the stove to the chimney . Inspect the chimney and chimney connector at least twice monthly , and clean if necessary .
27 Dutchwest Non-Catal ytic Con vection Heater 30002314 • Inspect for and remove ash build-up behind the com- bustion package. This should be done in conjunction with annual cleaning of the chimney connector since this inspection is most conveniently done through the flue collar opening.
28 Dutchwest Non-Catal ytic Con vection Heater 30002314 Y our stove is only one part of a system that includes the chimney , the operator , the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well.
29 Dutchwest Non-Catal ytic Con vection Heater 30002314 Single V enting Y our stove requires a dedicated flue. Do not connect the stove to a flue used by any other appliance. Chimney draft is a natural form of energy and follows the path of least resistance.
30 Dutchwest Non-Catal ytic Con vection Heater 30002314 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
31 Dutchwest Non-Catal ytic Con vection Heater 30002314 Dutchwest Convection Heater (continued) Model 2477 Ref. Description 2477 6. Outside Air Bracket 30002205 7. Fountain Assembly 30002100 8. Brick Support Bracket 30000986 9. Shoe Refractory 30002101 Shoe Gasket 30002286 10.
© CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation L I M I T E D L I F E T I M E W arranty For Dutchwest Non-Catalytic .
An important point after buying a device Vermont Casting 2477 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vermont Casting 2477 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vermont Casting 2477 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vermont Casting 2477 you will learn all the available features of the product, as well as information on its operation. The information that you get Vermont Casting 2477 will certainly help you make a decision on the purchase.
If you already are a holder of Vermont Casting 2477, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vermont Casting 2477.
However, one of the most important roles played by the user manual is to help in solving problems with Vermont Casting 2477. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vermont Casting 2477 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center