Instruction/ maintenance manual of the product HEPA 4100* Venmar
Go to page of 22
INST ALLA TION INSTR UCTIONS AND USER MANU AL RESIDENTIAL USE ONL Y INST ALLER: LEA VE THIS MANU AL WITH THE HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P AGES 18 T O 21.
ABOUT THIS MANU AL First, we want to cong ratulate you on y our purchase of this excellent unit which will allo w you and y our family to enjo y clean and health y air throughout your home f or years to come! Because of the large amount of models cov ered by this pub lication, the illustrations are typical ones.
1. T YPICAL I NST ALLA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 1.1 HR V 2600, HR 2.6, HEP A 3100, HF 3.1 AND HEP A 4100 U NIT I NST ALLA TIONS . . . . . . . . . . . .
1. TYPICAL INST ALLA TIONS Installations ma y vary according to the model number and the position in which the unit is installed. Use the f ollowing illustr ations as guidelines to help you decide on ho w your unit will be installed. All the units should be hung from the joists, and installed either v er tically or horizontally .
1. TYPICAL INST ALLA TIONS (CONT’D).
All 3 types of installations can be used in the attic (Stand Alone, Central Dr aw P oint or Retur n-Retur n). The example sho wn bel ow i s a Return-Retur n installation (connection to a forced air system). VH0051 - 6 - A por tion of stale air is exhausted to the outside and the rest is dr awn to the unit.
- 7 - 2.3 M OUNTING AND S ER VICING C ONSIDERA TIONS • The two f ollowing pictures are showing the minim um clearance needed to open the door completely . 22.5” 15.75” (572 mm) (400 mm) VD0117 VD0116 22” (559 mm) NO TE: A minimum of 8” (203 mm) clearance from an y obstruction on top of the unit is required for the ductwork radius turn.
- 8 - 3.3 L OCA TING THE U NIT Choose an appropriate location for the unit. • Within an area of the house where the ambient temperature is between 10°C (50°F) and 65°C (149°F) (basement, furnace room, closet, etc.). • So as to provide easy access to the interior of the unit, f or filter maintenance.
- 9 - 1. Route the cable from the unit to a con venient location f or the wall control. 2. Loosen the locking scre w (the screw cannot be completely remo ved). 3. Detach the f aceplate from the mounting plate by pulling the bottom par t. If necessar y , bore the mounting holes and inser t anchors.
7. T urn the unit switch knob to OFF position in order to unloc k the door. Unlatch the door and open it. If required, the door can be removed. T o do so , remov e the stopper ( A ) located on the right side of the door hinge. Then, hold the door and hit with your palm its left side .
5.2 H OW TO H ANG THE U NIT Use the 4 chains and springs in the hardware pack pro vided with the unit. According to your needs , you can install the unit either in vertical or hor izontal position.
- 12 - 5.3 P LANNING OF THE D UCTWORK All units in this manual are prebalanced. • K eep it simple. Plan for a minimum of bends and joints . • K eep the length of outside insulated duct to a minimum. • Do not v entilate cra wl spaces or cold rooms.
5.4 I NST ALLING N ON -I NSULA TED D UCTS AND R EGISTERS ( CONT ’ D ) 5.4.1 S TA N D A LONE S YSTEM ( AS ILLUSTRA TED IN S ECTION 1.1.1) ( CONT ’ D ) A LL UNITS How to connect the fle xible duct t.
5.4 I NST ALLING N ON -I NSULA TED D UCTS AND R EGISTERS ( CONT ’ D ) 5.4.2 C ENTRAL DRA W P OINT ( AS ILLUSTRA TED IN S ECTION 1.1.2) ( CONT ’ D ) Fresh/Filtered air ductwork (Return side connection) (cont’ d) HEP A 3100, HF 3.
5.5 I NST ALLING I NSULA TED F LEXIBLE D UCTS Use the f ollowing procedure f or connecting the insulated flexib le ducts to the T andem® transition* ( EXHA UST AIR TO OUTSIDE and FRESH AIR FROM OUTSIDE ).
5.5 I NST ALLING I NSULA TED F LEXIBLE D UCTS ( CONT ’ D ) 5.5.2 C ONNECTION TO THE 5’ ’ TO 6’ ’ O V AL PORTS OF THE UNIT ( CONT ’ D ) 4. Apply duct tape gently to the joint in order to make an airtight seal. 5. Repeat steps 1 to 4 f or the other 5’ ’ to 6’ ’ por t.
5.6 I NST ALLING D UA L E XTERIOR H OOD ( CONT ’ D ) 5.6.3 C ONNECTING T ANDEM ® TRANSITION TO EXTERIOR D UAL H OOD ( CONT ’ D ) 2. Join the end of the T andem transition to the rear of the e xter ior backplate. Secure with 2 Xmas tree pins and seal properly with duct tape.
6.1 M AIN S WITCH All units are equipped with a 3-position main s witch, located on the front panel. 6.2 40415 AND 40425 W ALL C ONTR OLS D ESCRIPTION The included wall control is 40415 (intented f or HR V 2600, HEP A 3100 and HEP A 4100 units only) or 40425 control (intented for HR 2.
6.4 W ALL C ONTROLS C ONFIGURA TION See the configuration tab le below f or the list of configuration parameters. Press the Menu b utton for 3 seconds to enter or e xit the configuration menu. NO TE: The wall control automatically sav es any changes and e xits the configuration menu if no b utton is pressed within the ne xt 60 seconds.
- 20 - 7. MAINTENANCE W ARNING Risk of electrical shocks. Before performing an y maintenance or servicing, al ways disconnect the unit fr om its power source. ! 7.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) P erf or m this maintenance when the Filter Maintenance LED is flashing .
- 21 - 7.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) ( CONT ’ D ) 6. W ash the 2 core filters under hot water with mild soap . Rinse thoroughly and let dr y completely bef ore reinstalling on the core. Remove the dust on the core using a v acuum cleaner with a soft brush attachment.
If the problem is still not solv ed, call your installer or the nearest authorized Service Center . Also , you can reach the Customer Service Depar tment at one of the following telephone n umbers: Exclusively f or models HRV 2600, HEP A 3100 and HEP A 4100: Exclusively f or models HR 2.
An important point after buying a device Venmar HEPA 4100* (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Venmar HEPA 4100* yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Venmar HEPA 4100* - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Venmar HEPA 4100* you will learn all the available features of the product, as well as information on its operation. The information that you get Venmar HEPA 4100* will certainly help you make a decision on the purchase.
If you already are a holder of Venmar HEPA 4100*, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Venmar HEPA 4100*.
However, one of the most important roles played by the user manual is to help in solving problems with Venmar HEPA 4100*. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Venmar HEPA 4100* along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center