Instruction/ maintenance manual of the product SBVBP(C) Vanguard Heating
Go to page of 32
CAST IRON STOVE AND B-VENT (FREEST ANDING FIREPLACE HEA TER) BURNER SYSTEM ® OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS BURNER SYSTEM SBVBN(C) PROP ANE/LP GAS BURNER SYSTEM SBVBP(C) REMOTE READY Save this manual for future reference.
2 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
3 106828 OWNER’S MANUAL For more information, visit www.desatech.com P I L O T L O H I OFF ON PRODUCT IDENTIFICA TION Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.
4 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Vanguard B-vent cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system.
5 106828 OWNER’S MANUAL For more information, visit www.desatech.com Pallet Wood Bolted to Bottom of Stove Body STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body .
6 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBL Y Continued Figure 11 - Attaching Stov.
7 106828 OWNER’S MANUAL For more information, visit www.desatech.com CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBL Y Continued INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY 1. Carefully lift burner system and place into stove body from the rear of stove.
8 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) INSTALLING REAR COVER 1 . Place rear cover behind stove body . Rear cover will rest on the bottom ledge of the stove body . 2 . Place wire harness from ON/OFF switch under the cast of stove body .
9 106828 OWNER’S MANUAL For more information, visit www.desatech.com CAST IRON STOVE AND DIRECT -VENT BURNER SYSTEM ASSEMBL Y Continued Figure 20 - Control Valve Terminals To Control Switch INSTALLATION PRECAUTIONS Consult local building codes before begin- ning the installation.
10 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) CHECKING VENT CAPACITY Complete all gas piping, electrical, and vent connections. After adjusting the burner sys- tem and lighting the main burners, allow a couple of minutes for warm-up.
11 106828 OWNER’S MANUAL For more information, visit www.desatech.com VENTING INST ALLA TION Continued • Complete familiarity with chimney con- dition, height, size, clearance to combus- tibles and other factors is essential.
12 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) CAST IRON STOVE AND B-VENT BURNER SYSTEM INST ALLA TION INSTALLING GAS PIPING TO STOVE LOCATION WARNING: A qualified in- staller or service person must connect burner system to gas supply.
13 106828 OWNER’S MANUAL For more information, visit www.desatech.com CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to burner sys- tem.
14 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) Test Pressures Equal To or Less Than 1/2 PSIG (3.
15 106828 OWNER’S MANUAL For more information, visit www.desatech.com Figure 32 - Checking Gas Joints for Propane/LP Gas Burner System Propane/ LP Supply Tank Equipment Shutoff Valve Gas Valve Equip.
16 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES - GHRC AND GHRCTA SERIES Installing Remote Receiver 1. Open bottom door on stove body .
17 106828 OWNER’S MANUAL For more information, visit www.desatech.com REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this burner system with a broken glass door panel or without the glass door panel securely in place. For replacement part in- formation see Replacement Parts , page 26.
18 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) CAST IRON STOVE AND B-VENT BURNER SYSTEM INST ALLA TION Continued It is very important to install these logs exactly as instructed in Figures 43 through 47 .
19 106828 OWNER’S MANUAL For more information, visit www.desatech.com TO TURN OFF GAS TO APPLIANCE 1. Set ON/OFF switch located on r ear cover to “OFF”. 2a. Open lower panel. 2b . If Using Optional Hand-Held Remote: Set selector switch in the OFF posi- tion to pre vent draining battery .
20 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) 1. After lighting, let pilot flame burn f or about one minute. T urn contr ol knob on the control valv e to ON position. T urn flame adjustment knob any- where between HI and LO.
21 106828 OWNER’S MANUAL For more information, visit www.desatech.com INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling.
22 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) CLEANING AND MAINTENANCE WARNING: Turn off burner system and let cool before cleaning. CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of stove with burner system clean.
23 106828 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off burner system and let cool before ser- vicing. Only a qualified service person should service and repair heater.
24 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burn.
25 106828 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
26 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) SER VICE HINTS When Gas Pressure is Too Low: • pilot will not stay lit • burners w.
27 106828 OWNER’S MANUAL For more information, visit www.desatech.com SPECIFICA TIONS SBVBN(C) SBVBP(C) 21,000-30,000 Btu/h 20,000-28,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.
28 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) ILLUSTRA TED PA R T S BREAKDOWN SBVBN(C) SBVBP(C) L O H I P I L O T OFF ON 4 4 17 18 1.
29 106828 OWNER’S MANUAL For more information, visit www.desatech.com KEY NO. PART NUMBER DESCRIPTION QTY. 1 106796-01BR Firebox Assembly 1 2 105795-01 Glass Door Assy 1 3 106836-02CK Rear Cover 1 4.
30 ® CAST IRON STOVE AND BURNER SYSTEM 106828 For more information, visit www.desatech.com SBVBN(C) AND SBVBP(C) ILLUSTRA TED PA R T S BREAKDOWN AMITY™ SCIVFC(*) SERIES PSCIVFC(*) SERIES (* Indicat.
31 106828 OWNER’S MANUAL For more information, visit www.desatech.com P AR TS LIST AMITY™ SCIVFC(*) SERIES PSCIVFC(*) SERIES (* Indicates Color Suffix Designation) This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
LIMITED WARRANTY B-VENT BURNER SYSTEM AND AMITY ™ STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
An important point after buying a device Vanguard Heating SBVBP(C) (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vanguard Heating SBVBP(C) yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vanguard Heating SBVBP(C) - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vanguard Heating SBVBP(C) you will learn all the available features of the product, as well as information on its operation. The information that you get Vanguard Heating SBVBP(C) will certainly help you make a decision on the purchase.
If you already are a holder of Vanguard Heating SBVBP(C), but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vanguard Heating SBVBP(C).
However, one of the most important roles played by the user manual is to help in solving problems with Vanguard Heating SBVBP(C). Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vanguard Heating SBVBP(C) along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center