Instruction/ maintenance manual of the product 22AF United States Stove
Go to page of 32
1 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• C O M P A N Y U N I T E D S T A T E S S T O V E C S S U CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE FUR.
2 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• TOOLS AND MATERIALS NEEDED TOOLS Pencil 6 Foot Folding Rule or Tape Tin Snips Drill, Hand or Electric Drill Bit (For Sheet Metal Screws) 1/8" Dia.
3 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CAUTION Your Furnace has the following labels. Read and obey all labels. REFER TO MARKINGS ON THE APPLIANCE FOR ADDITIONAL INFORMATION.
4 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Read these rules and the instructions carefully. Failure to follow them will cause a hazard that could result in death, serious bodily injury, and/or property damage. Check your local codes. This installation must comply with their rulings.
5 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Your Ashley Furnace is designed to be a supplemental or central heating source for your home. This solid fuel furnace may be installed in conjunction wi.
6 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF DIMENSIONS FIG. 1.
7 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• 1. 2. 3. 4. FIG. 3 The furnace should be located in the same room as the central system and as close as possible, but no closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace.
8 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• LISTED FACTORY BUILT CHIMNEY Carefully follow chimney manufacturer's instructions. Use only a Listed Residential Type or Building Heating Appliance Chimney. If your chimney starts at the ceiling (Fig.
9 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• RULES FOR CONNECTOR PIPE INSTALLATION FIG. 6 The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chimney connector and elbow with the CRIMPED END TOWARD THE FURNACE.
10 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall.
11 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MINIMUM 12 IN. TO COMBUSTIBLES PART A, FIGURE 8 (FIGURE 8 CONTINUED ON NEXT PAGE) Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall.
12 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• PART B FIGURE 8 - (FIGURE 8 CONTIN- UED) AIR SPACE 9 IN. MINIMUM FACTORY-BUILT CHIMNEY LENGTH MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.
13 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• BLOWER & COMPONENT ASSEMBLY - FIG. 9 JUNCTION BOX MOUNTING BRACKET 1. Attach the Fan Limit Control Bracket to the rear of the furnace with four(4) of the #10 x 1/2 Tek screws provided in the parts bag.
14 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF WIRING DIAGRAM - FIG. 11 WIRE COLOR CODE G- GREEN- GROUND B- BLACK- POWER SUPPLY W- WHITE- POWER SUPPLY R1- WHITE- FAN CONTROL R2- BLACK- FAN CONTROL M1- BLACK- BLOWER MOTOR M2- WHITE- BLOWER MOTOR Fig.
15 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Please see all methods of Installation in Appendix at the rear of this booklet. This is a furnace, not a free standing stove. You must direct heated air from 12" outlet away from the furnace, or it will not function properly.
16 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• POWER FAILURE INSTRUCTIONS: Operation after loss of power Remove filter if provided. Do not expect to keep home at normal temperatures. Do not load fuel above bottom of feed door. Set Fuel door and Ash door spin draft maximum closed per the factory installed stops.
17 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CENTRAL INSTALLATION (U.S. & CANADA) (FIGURE 12) ADD-ON INSTALLATION (U.S. ONLY) (FIGURE 13).
18 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• ALTERNATIVE PARALLEL INSTALLATION WIRING DIAGRAM - FIG. 14 TO GAS/OIL/ELECTRIC TRANSFORMER HOTBLAST COMBINATION CONTROL LIMIT FAN JUMPER IN H H POWER S.
19 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• CAUTION GASES THAT ARE DRIVEN BY FRESH COAL MUST BE BURNED OR THEY WILL ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH COAL. CAUTION DO NOT OPERATE WITH THE FEED AND/OR ASH DOOR OPEN. THIS FURNACE IS DESIGNED FOR THERMO- STATIC OPERATION.
20 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or exces- sive build-up of water or creosote in the chimney would keep it from functioning properly.
21 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF - PARTS.
22 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• MODEL 22AF - PARTS LIST KEY PART NO. DESCRIPTION QTY. 1 69356 Firebox Weldment 1 2 88032 Flue Collar Gasket 1 3 40246 Flue Collar 1 4 25102R Cabinet Si.
23 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION A NOTE: ANTI-BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION..
24 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION B NOTE: ANTI-BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION..
25 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION C NOTE: ANTI-BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION..
26 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION D (U.S. ONLY) INSTALLATION E (U. S. ONLY).
27 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• APPENDIX INSTALLATION F INSTALLATION G.
28 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• 1. Smoking when feed door is open. 2. Furnace does not heat. 3. Blower does not run. 4. No air from registers - fan running. 5. Air from registers is not hot. 6. Blower runs too long. 7. Blower does not run long enough.
29 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• NOTES.
30 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• NOTES.
31 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• TYPE WEIGHT PER CORD EFFICIENCY SPLITS MILLIONS (LBS. CU. FT., DRY) RANKING BTU's/CORD Hickory 63 4500 1. 0 Well 31.5 White Oak 48 4100 . 9 Fair 28.6 Red Oak 46 3900 . 8 Fair 27.4 Beech 45 3800 . 7 Hard 26.
32 •DRAWINGS FOR ILLUSTRATION PURPOSES ONLY• THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR HOTBLAST FURNACE, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
An important point after buying a device United States Stove 22AF (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought United States Stove 22AF yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data United States Stove 22AF - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, United States Stove 22AF you will learn all the available features of the product, as well as information on its operation. The information that you get United States Stove 22AF will certainly help you make a decision on the purchase.
If you already are a holder of United States Stove 22AF, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime United States Stove 22AF.
However, one of the most important roles played by the user manual is to help in solving problems with United States Stove 22AF. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device United States Stove 22AF along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center