Instruction/ maintenance manual of the product 1303 United States Stove
Go to page of 24
ASSEMBL Y INST ALLA TION OPERA TION REP AIR P AR TS CAUTION IMPROPER INSTALLATION READ ALL INSTRUCTIONS CAREFULLY MAY VOID YOUR WARRANTY BEFORE STARTING THE INSTALLATION SAVE THIS MANUAL FOR OR OPERAT.
CONGRA TULA TIONS! Y ou'v e purchased one of America's Finest W ood Bur ning Heaters. By heating with wood and coal, y ou're helping CONSER VE AMERICA'S ENERGY! W ood is our Rene wab le Energy Resource. Please do your par t to preser v e our wood supply .
Y our Fur nace has the f ollowing labels . Read and obey all labels . DANGER: RISK OF FIRE OR EXPLOSION DO NOT burn garbage, gasoline, drain oil, or other flammable liquids. W ARNING: FIRE HAZARD DO NO T operate with fire draft e xceeding .06 inches w .
Rules for safe installation and operation Read these rules and the instructions carefully. Failure to follow them will cause a hazard that could result in death, serious bodily injury, and/or property damage. 1. Check your local codes. The installation must comply with their rulings.
How The Furnace Functions PARALLEL INSTALLATION: The design is such that when the blower comes on, the blower will only come on when the temperature in the plenum has reached the setting on the blower control. This is to insure that there is sufficient warm air in the system to make it efficient for the unit to operate.
1303 DIMENSIONS Shown in Fig. 1 are the dimensions of the furnace. 6 20 36 3/8 32-1/8 2 30 - 9/16 41 Fig. 1.
1. The furnace should be located in the same room as the central system and as close as possible, but not closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace.
Chimney Connection MASONR Y CHIMNEY Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the furnace. See page 4, item 5. Look at Fig. 4. The connector pipe and fittings you will need to connect directly to a masonry chimney are shown.
Rules for Connector Pipe Installation 1. The crimped end of the chimney connector fits inside the furnace flue collar. Install additional chim- ney connectors and elbow with the CRIMPED END TOWARD THE FURNACE. This will allow any condensation in the flue to run back into the furnace.
Assembly of Furnace Your furnace requires the following items to be assembled or installed by the service person: BLOWER AND BLOWER CONTROLS ELECTRICAL CONNECTIONS 1 . Remove all parts from inside the furnace and inspect for damage. Including the firebrick, as some damage could have occurred during shipment.
Model 1303 Wiring Diagram 11 LOAD FAN LINE LOAD LIMIT LINE BREAK OFF JUMPER FOR LOW VOLTAGE FAN "OFF" INDICATOR FAN "ON" INDICATOR LIMIT INDICATOR Honeywell LIMIT SWITCH R1 R2 G W 110 VAC, 60 HZ. GROUND G B W ELECTRICAL JUNCTION BOX M1 M2 BLOWER MOTOR IMPORTANT: POWER SUPPLY WIRING MUST NOT BE LESS THAN 90 CENTIGRADE.
Installation Please see all methods of Installation in Appendix at the rear of this booklet. This is a furnace, not a free standing stove. You must direct heated air from 8" outlets away from the furnace, or it will not function properly. 1. This installation must be done by a qualified heating equipment installer.
1 23466 Cabinet Left Side 1 2 23464 Cabinet Back Panel 1 3 88032 Flue Collar Gasket 1 4 40246 Flue Collar 1 5 22761 Flue Collar Ring 1 6 83086 Flue Collar Mounting Bolts 1/4-20x3/4" 4 83227 Flue .
14 MODEL 1303 (See Repair Parts List on Page 13) 9 10 41 11 38 7 6 3 1 2 39 4 25 23 24 22 20 17 14 18 16 13 15 26 37 34 35 33 32 31 36 29 28 27 40 19 5 8 30 12 21 42.
Power Failure Instructions: Operation after loss of power-- 1. Remove filter if provided 2. Do not expect to keep home at normal temperatures. 3. Do not load fuel above bottom of feed door. 15 2" MIN. AIR SPACE REQUIRED BY CODE 18" MIN. CENTRAL FURNACE Fig.
16 COLD AIR DUCT 6" PIPE DAMPER OPTIONAL 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Central Installation Fig. 11 Add-On Installation COLD AIR DUCT 6" PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS/OIL/ELECTRIC FURNACE 8" PIPE FIG.
ADJUSTING BLOWER LIMIT CONTROL SET- TINGS The temperature in the plenum of the warm air furnace at which the blower turns on or turns off, is controlled by the setting of the pointers in the blower limit control. (See Fig. 12) These point- ers may be adjusted to achieve the desired warm air output from the furnace.
Service Hints Do not expect a furnace to draw. It is the chimney that creates the draft. Smoke spillage into the house or excessive buildup of water or creosote in the chimney are warnings that the chimney is not functioning properly. Correct the problem before using furnace.
T rou ble Shooting Tips f or W arm Air Furnace 1. Smoking when feed door is open. 2. Furnace does not heat. 3. Blower does not run. 4. No air from registers- fan running. 5. Air from registers is not hot. 6. Blower runs too long. 7. Blower does not run long enough.
20 COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE MODEL 1303 FURNACE FILTER BOX APPENDIX INSTALLATION A.
21 INSTALLATION B INSTALLATION C COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE MODEL 1303 FURNACE FILTER BOX PLENUM COLLECTOR BOX COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXIST.
22 2" MINIMUM CLEARANCE DUCT WORK 11 PCS (OPTIONAL PLENUM FAN CONTROL LOCATION) FURNACE PLENUM EXISTING FURNACE ANTI-BACKDRAFT FLAPPER SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION D 2" MI.
23 2" MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2" MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR .
OWNERS MANUAL HO W T O ORDER REP AIR P A R TS OR "OPTIONS" THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE FURNACE, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY.
An important point after buying a device United States Stove 1303 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought United States Stove 1303 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data United States Stove 1303 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, United States Stove 1303 you will learn all the available features of the product, as well as information on its operation. The information that you get United States Stove 1303 will certainly help you make a decision on the purchase.
If you already are a holder of United States Stove 1303, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime United States Stove 1303.
However, one of the most important roles played by the user manual is to help in solving problems with United States Stove 1303. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device United States Stove 1303 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center