unidE!n$ UHF CB TRANSCEIVER OWNER'S MANUAL SUNDOWNER UH-O99 SCANNING unldm 11 SCAN OSlGS r - UH-099 D D ID CAL MEM CUP 1SQ " "" 1 SRF os - "" "'j",, GS 0 0.
Contents Controls/lndicators/Connections 2 Front Panel Controls 2 FrontPanel Indicators 3 Microphone " " ... 4 Back Panel "... 5 Getti ng Started 6 Mobile Station Installation 6 Choosin.
Contro 15/1 nd icators/Con nactio ns CHANNEL SELECTOR Selects the desired channel for transmission and reception. SCAN CONTROL (SCAN) Scans channels programmed in the selected SCAN mode. NOTE: The radio will not scan if the selected Scan Memory has not been programmed.
8. SQUELCH CONTROL Eliminates received background noise in the absence of an incoming signal. Turn the control knob fully counter-clockwise and then slowly rotate clockwise until the received noise is eliminated. 9. VOLUME CONTROL Turns the radio on and increases the volume level when turned clockwise.
Microphone 1 2 1. PRESS- TO-TALK Button Use the PRESS- TO-TALK button on the microphone to receive and transmit. Press the button to activate the transmitter and release the button to receive. When transmitting, hold the microphone about two inches from your mouth and speak clearly in a normal voice.
Back Panel IIXI' ... ~ (8) 3 1. EXTERNAL SPEAKER JACK (EXT.SP) Used for remote receiver monitoring. When the external speaker is connected the internal speaker is automatically disconnected. 2. POWER DC power is connected to the transceiver through this jack.
Getting Started Mobile Station Installation Select the location of the transceiver and microphone bracket before starting the installation. The location should be convenient and should not interfere with the driver or passenger in the vehicle.
Operation How to Receive 1. Confirm that the power source, antenna, and microphone are connected properly before proceeding to the following steps. 2. Turn the unit ON by rotating the VOLUME control clockwise. 3. Set the CHANNEL CONTROL knob to the desired channel.
Scanning Pressing the SCAN button one time will initiate scanning, and scanning is stopped either by pressing the button a second time or pressing the Press-to- Talk button. Programming Scan Channels When the radio is initially turned on, there will not be any channels programmed in the Group Scan Memory.
Removing Group Scan Channels To Delete a programmed channel from the Group Scan Memory, use the following procedure: 1. Rotate the CHANNEL SELECTOR knob until the channel you wish to remove is displayed. Note that the MEM indicator should appear, indicating that this channel is currently programmed in memory.
Group Scanning Tocommence GROUP SCANNING, select the GROUP SCAN mode by pressing the OS/GS button when in the OS mode, and select the SCAN mode by momentarily pressing the SCAN button. The SUNDOWNER UH-O99 will now scan the programmed channels, displaying each channel number and the PRIORITY channel number.
Removing Open Scan Channels When the radio is initially turned on, all 40 channels are programmed in the OPEN SCAN MEMORY. If you do not wish to scan some particular channels (e.
Reinstalling Channels into the Scan Group To reinstall previously deleted channels into the scan group, simply repeat steps 3 and 4. However, this time note that a beep will be heard when the MEM button is pressed, and the MEM indicator will light, indicating that the selected channel is now included in the scan group.
Selective Calling Outline Selective Calling (SELCALL) is a special Sequential Tone Squelch System that allows the user to receive/transmit calls selectively from/to an individual or a group, on a shared busy channel. The SUNDOWNER UH-O99 has a specially built-in Selective Calling (SELCALL) system.
Receiver Quieting Puts the receiver in the "Ouiet" mode (also known as the "Tone Squelch" mode). When activated, the transceiver prevents any unwanted conversations in the channel .
Start the T.Sa Scan by pressing the T.Sa button during Open Scan or Group Scan. Unlike Normal Scanning, T.Sa Scanning checks the detected carrier for SELCALL information. If this information is not found, T.Sa scanning resumes. When a call is received during T.
1. 2. Select the channel that you and your group agreed to use for Selective Calling. Press and hold the Tone Call Button for about 1.5 seconds. One long beep will be heard and the CAL indicator will appear on the LCD display while the SELCALL ID is being transmitted automatically.
Assign a SELCALL number on this position. Follow procedure 1.1 for further TX SELCALL ID editing. When finished, press I MEM I or transmit the code ENT to save the new setting onto memory. 1.22 From 6 to 5 Tone Format Setting Select the 6th digit position, change the setting from the assigned SELCALL number to a space bar [-].
TX SELCALL ID Format To call Transmitter SELCALL ID 10 radios 100 radios 1 000 radios 1 0000 radios [xl [xl [xl [xl [AJ [xl [xl [xl [AJ [AJ [xl [xl [AJ [AJ [AJ [xl [AJ [AJ [AJ [AJ where: [xl is a common SELCALL ID prefix of your group and, [AJ is the CCI R Assigned Group Tone Code example: If one group comprises 10 members with SELCALL IDs.
5/6 TONE SELCALL PROGRAMMING Since UH-O99 can support either a 5 or 6 tone signalling format, you and your group must decide which format to use. The following is a basic outline of SELCALL Programming.
Receiver SELCALL ID To program your own receiver SELCALL ID, perform the following procedure. Press and Hold I TSQ I, then turn on the Power. 1.1 Initial Display and Status (factory default: 00000) RX SELCALL Code Programming ,-, It ,-, ,-, ,-, UUUUf-t TSQ I ,~ " ~ ~ 1.
" " " " ,~ I1 " Uf-If-IUY - - 11 TSQ I ,-- " ~ ~ Assign a SELCALL number on this position. Follow procedure 1.2 for further RX SELCALL ID editing.
Tone Period Tone Period is the duration of one tone in a SELCALL I D sequence. The setting of this parameter depends on the type of application. On long distance communications for example, where the signal strength of the transmitted information is greatly reduced and affected by noise, it is advisable to use a longer Tone Period.
Rotate the 0 to change the Tone Period value. Channel Knob [ 020 TSQ " ..71 ,- I..lJ [ 100 1SQ ,Odj -PdJ [ 040 TS4PdJ c: When finished, press I ME M I to store onto memory. The displayed Tone Period ENT stops flashing and three successive beeps will be heard.
Lead-in Delay Lead-in Delay is a SELCALL transmission parameter that "wakes-up" and helps the receiver of the other radio to lock onto the incoming signal.
When finished, pressl MEM I to store onto memory. The displayed Lead-in Delay ENT stops flashing and three successive beeps will be heard. pressl TSQ I for about 1.5 seconds to exit. The radio returns to normal operation. Or press I TSQ I momentarily to go to the next programmable parameter.
~one_1 T$O 1 11 L ,~ GJ1Ie_o T$O 1 11 L ,~ [TOnem2 T$O 1 11 L ,~ ~.n. T$O 1 TI - Ll T$O 1 11 L ,~ [TO80m3 T$O 1 11 LI~ . Gone_F . . . . . . . [Tone C Note: If you want to remove the Lead-in Tone, choose the Space [-] Bar. When finished press I MEM I to store onto memory.
Alarm Mode 5.1 From the Lead-in Tone condition (4.1) press I TSQ I and the following mode appears. 't , , ,- 'tU' Q TSQ " I "L 5.2 Next press I MEM I and Alarm Mode Editing is possible. ENT '~JI ,,- '-'u' a TOO " I " L- L.
Call Alarm Continue Mode 1. The unit will transmit an Acknowledge Tone to the Caller. 2. Initially emits an alarm of four successive beeps for 20 seconds and then two successive beeps every four seconds continuously unless answered. 3. Never resumes the Quiet Condition.
Care and Maintenance Notice If the UH-099 has been subjected to extreme high .temperature (above 60°C) for a prolonged period of time, blackening of the Liquid Crystal Display (LCD) may occur. This is not a fault. Normal LCD operation resumes when the temperature stabilises back to proper operating conditions (0 to 55°C).
UHF CB Channel Information This radio has been designed to provide a high level of performance in the Citizens Band Radio Service, which is comprised of the following frequency assignments: SIMPLEX Operating Mode Page 30 Channel Channel Frequency in MHz 1 476.
DUPLEX Operating Frequencies Page 31 Channel Receive Transmit Assignment Frequency (MHz) Frequency (MHz) CH1 476.425 477.175 (CH31) CH2 476.450 477.200 (CH32) CH3 476.475 477.225 (CH33) CH4 476.500 477.250 (CH34) CH5 476.525 477.275 (CH35) CH6 476.550 477.
Specifications General Channels Frequency Range Crystal Oscillator Microphone Speaker Antenna Connector Jacks & Connectors Controls Indicators Cabinet Size Weight Operating Temperature Power Requirements SMA Approval Accessories : 40 : 476.425MHzto 477.
Measurement Conditions Power Source : 13.8V (DC) Antenna Impedance : 50 ohm Test Temperature : 25°C Modulation Frequency: 1 kHz (RXITX) Mean Signal Input Level: 1 000 ~V Reference Audio Output Power .
Current Drain at No Signal Current Drain at Maximum Output SELCALL Standard Encode/Decode Format Transmit Tones Receive Tones Tone Periods Lead-In Delay Lead-In Tone : 300mA : 600mA : CCIR Internation.
Warranty Uniden Sundowner UH-O99 UHF CB Radio Australian One Year Warranty Note: Please keep your sales docket as it provides evidence of warranty. WARRANTOR: UNIDEN Australia Pty.
~ - ~"~"-: ---L- uniden@ Australia Pty. Ltd. 345 Princess Highway, Rockdale, N.S.W. 2216 Phone: (02) 599 3100 Fax: (02) 599 3278 Unlden@ is a registered trademark of Uniden Corporation. Features, specifications, and availability of optional accessories are all subject to change without notice.
An important point after buying a device Uniden UH-099 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Uniden UH-099 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Uniden UH-099 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Uniden UH-099 you will learn all the available features of the product, as well as information on its operation. The information that you get Uniden UH-099 will certainly help you make a decision on the purchase.
If you already are a holder of Uniden UH-099, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Uniden UH-099.
However, one of the most important roles played by the user manual is to help in solving problems with Uniden UH-099. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Uniden UH-099 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center