Use and Car e Guide CLR2160 CLRCO217 5 Clear Ice Ma ker Model: CLR2160 Clear Combo ® Ice Maker/Re frigerator Model: CLRCO2175 ULIN_016357_30096.fm Page 1 Wednesd ay, February 7, 2007 12:46 PM.
2 CLR2160 , CLRCO 2175 Congratulation s on your purchase of a U-Line refrigeration prod uct. A pioneer in the fiel d for more than 40 years, U-Line Corporation is the world’ s number one manufacturer of built -in, un der-co unter , spe cialty refrigeration a nd ice making products.
CLR2160 , CLRCO2175 3 Introduction ...... ............................ ........... ................. ................. ................. ................ .. .......... ...2 Warranty Registrati on ............... ............ ................. ........
4 CLR2160 , CLRCO 2175 This page intentionally left blank.
CLR2160 , CLRCO2175 5 IMPORT ANT IMPORT ANT PLEASE READ all instructions completely before attempting to install, operate, or service your unit. • Pr oper installation procedur es must be followed if this unit is being initially installed, or is moved to a new loc ation afte r bein g in se rvice.
6 CLR2160 , CLRCO 2175 Échelon Model CL R2160 Clear Ice Maker , Model CLRC O2175 Clear Ice Maker/Refrigerator CLR2160 • This model produces up to 60 lbs (27.2 k g) of ice per day , will store 30 lbs (1 3.6 kg). • Stainless steel model is deemed suitable for outdoor use by UL.
CLR2160 , CLRCO2175 7 Figure 2 IMPORT ANT IMPORT ANT Proper air flow (Figure 2) is required for your unit to operate at its highest efficiently . A grille, located in the base of the unit, must not be blocked at any time, or your unit will not perform as expected.
8 CLR2160 , CLRCO 2175 T emperature Control Checking Pr oduct T emperatur e Figure 4 T o check the actual product temperature, in refrigerator section only , insert an accurate thermometer into a plastic (non-breaka ble) bottle that is pa rtially filled with w ater .
CLR2160 , CLRCO2175 9 T emperatur e Display T o displa y the Model CLRCO217 5 interior temperature: 1. T ouc h and h old t he WARM ER ic on (Figure 5, 2) for approxima tely five second s and relea se when the °F symbol in th e display (Figur e 5, 3) begins to flash.
10 CLR2160 , CLRCO2175 Storage, V acation, M oving If the unit wi ll not be u sed for an extended period, or otherwise stored, follow these steps completely: WA R NI N G Electrical Shock Hazard. Disconnect power befor e servicing. Before operating, r e place all panels.
CLR2160 , CLRCO2175 11 General Cleaning Exterior Cleani ng (As Required) Black and White Models : • Surfaces may be cleaned with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a so ft sponge and rinse with clean water .
12 CLR2160 , CLRCO2175 T o defrost: 1. T urn unit off. 2. Remove all products from the interior and prop the door in an open position (2 in. (5 c m) minimum).
CLR2160 , CLRCO2175 13 Figure 9 1. T urn the ice ma ker of f (allowing any ic e to melt o ff of the evapo rator) as fo llows: a. T o uch an d hol d the ON/OFF butt on (Figure 9, 1) . b. The disp lay (Figure 9 , 3) will sw itch from ICE to OFF to confirm that the i ce maker is off.
14 CLR2160 , CLRCO2175 Fig ure 12 4. Disconnect the hose connector (Figure 12, 1) from t he water solenoi d valve (Figure 12, 2) . 5. DO NOT remove the inlet screen (Figure 12, 3) from the water solenoid valve. Use a toothbrush to gently clean a ny sedi ment from the inle t scree n.
CLR2160 , CLRCO2175 15 Fig ure 15 A unit that is not le vel can ca use a reduction in ice rate, uneven siz ed cubes or water spilling into the storage ar ea, which will cause the ice in the bin to melt prematurely (Figur e 15) . When checking the level, remember that floors near drains have a tendency to slo pe towards the drain.
16 CLR2160 , CLRCO2175 Fig ure 20 3. T urn the door upside down and inspect the hinge plate mounting holes. • Y our plate has slotted mounting hole s (Fig ur e 20, 1) . Loosen but do not remov e the two hinge plate sc rews. 4. If door edge opposite the hinges needs to move up, move plate toward outside of door (Figure 20, 2) .
CLR2160 , CLRCO2175 17 Fig ure 24 2. Remove plastic screw plugs (three each, top and bottom) (Figure 24, 1) from new hinge location. Do not discard. 3. Remove top hinge (three screws) (Figure 23, 2) and reinstall hinge screw pin (Figure 23, 1) . Fig ure 25 4.
18 CLR2160 , CLRCO2175 Door Shelf Removal/Insert ion Fig ure 28 T o remov e the do or she lf: 1. Grasp shelf in center , lift slightly , and tilt 15°-20°. 2. Carefully pull shelf off bosses (Fi gur e 28, 2) . T o install the door shelf: 1. Holding shelf in center , align notche s (Figure 28, 1) in shelf with bosses (Fi gur e 28, 2) in door .
CLR2160 , CLRCO2175 19 Light Bulb Replacement CLRC O2175 T o repla ce the light bulb i n your U-Line unit: Fig ure 30 1. Grasp the edges of th e light housing lens (Figur e 30, 1) opposite the exposed tab, and gently push the lens to wards the tab (Figure 30, 2) .
20 CLR2160 , CLRCO2175 Fig ure 32 If using a Grav ity Drain: 1. Attach the 5/8-inch ID drain conn ection on the back of the unit to a 5/8-inch O D rigid tube, using a worm clamp. 2. Attach the other end of the rigid tube to your 5/8-inch ID drain line with a worm clamp.
CLR2160 , CLRCO2175 21 T o check and test h ose connections: 1. Make certain the unit is no t plugged into a n electrica l outlet. 2. Carefully push the power cord grommet through the hole in the back panel (see Figur e 36 ). Fig ure 36 3. Remove 12 screws and back panel.
22 CLR2160 , CLRCO2175 CAUTIO N In the event of a power outage, r estricted drain or pump failur e, the failur e to use the U-Line P60 drain pump or a pump with the above listed specifications, could r esult in substantial water leakage and pooling wit h severe and costly wate r damage and r elated consequential damages and harm.
CLR2160 , CLRCO2175 23 Electrical Spe cifications CAUTIO N Electrica l installation must observe all state and local codes. This unit re quires conne ction to a grounded (three-prong), polarize d receptacle that has been placed by a qua lified electrician.
24 CLR2160 , CLRCO2175 T roubleshooting Guide DANGER ELECTROCUTION HA ZARD Never attempt to repair or perform maintenance on the unit until the main electrical power has bee n disconnected. NOTE: Recommended r efrigerat or tempe rature set ting is 38°F .
CLR2160 , CLRCO2175 25 Unit runs but produces very l ittle ice. Dirty condenser coils Clean the condenser (See M AINTENANCE; CONDENSER CLEANING). High ai r temperat ure aro und unit Surrou nding air tempera ture of o ver 90 °F . Low ice product ion at high tempe rature s is nor mal.
26 CLR2160 , CLRCO2175 Electronic Contr ol Quick G uide NOTE: 38°F is an exam ple; the displa y will vary w ith actual set-point. IMPORT ANT Factory recommende d set-point is 38°F for refrigerators and beverage centers, and 50°F for wine c oolers.
CLR2160 , CLRCO2175 27 U-Line Corpora tion L imited Warranty U-Line Corpo ration warrants eac h U-Line prod uct to be free from defects in materials and workmanship for a pe riod of one year from the .
For General Inquiries: P .O. Box 245 040 Milwa ukee, Wis consin 53224-95 40 U.S.A. Phone (80 0) 779-2547 F A X (414) 354-5 696 www .U-Line.com For Service and Parts Assist ance : Phone (80 0) 779-2547 (414) 354-030 0 F A X (414) 354-5 696 Ema il: OnLine Service @U-Line .
An important point after buying a device U-Line CLR2160 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought U-Line CLR2160 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data U-Line CLR2160 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, U-Line CLR2160 you will learn all the available features of the product, as well as information on its operation. The information that you get U-Line CLR2160 will certainly help you make a decision on the purchase.
If you already are a holder of U-Line CLR2160, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime U-Line CLR2160.
However, one of the most important roles played by the user manual is to help in solving problems with U-Line CLR2160. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device U-Line CLR2160 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center