Instruction/ maintenance manual of the product ADA24RGL U-Line
Go to page of 20
Use and Car e Guide ADA24R ADA24RGL ADA SERIES Refrigerator Models: ADA24.
ADA24 , ADA SERIES Congratulations on your purc hase of a U-Line refrigeratio n product. U-Lin e Co rporatio n, a pioneer in the applianc e industry for more than 40 years, is the world’ s number one manuf acturer of built-in, un dercounter , specialty refrigeration and ice making prod ucts.
ADA24 1 ADA SERIES ADA24 Introduction .. .............. ............ ........... .............. ........... ........... .............. ......... Inside Front Cov er Warranty Registration .................... ............ .. ......... ........... .....
2 ADA24 ADA SERIES IMPORT ANT IMPORT ANT PLEASE READ all instruct ions completely before attempting to install, operate, or ser vice your unit. • Proper installation pr ocedures must be followed if this unit is being initially installed, or is moved to a new location after being in service.
ADA24 3 ADA SERIES Origins Refrigerator ADA24R, ADA24RGL • Features an ele ctronic cont rol panel with di gital displa y that allows you to display the interi or temperature and adjust the setting to your preference.
4 ADA24 ADA SERIES Interior Lighting The interior of the cabinet can be illuminated w henever the door is opene d or remained darke ned for a 36-hour period (blacko ut/Sabbath mode [not Star K cert ified]). Figure 3 The LIGHT button (Figure 3, 1) on the control panel is used to change the lighting function s.
ADA24 5 ADA SERIES Checking Product T emperature Figure 5 IMPORT ANT IMPORT ANT U-Line re commends a set te mperat ure of 38°F on all refr igerators. T o check the actual produc t temperature in your unit, insert an accurate thermo meter into a pla stic (non- breakable) bottle that is pa rtially filled with water .
6 ADA24 ADA SERIES Normal Operating Sounds All models incorporate rigid foam insulated cabinets to provide high thermal effi ciency and maximum sound reduction for its internal work ing components. In spite of this technolo gy , your mode l may make sounds that are unfamiliar .
ADA24 7 ADA SERIES General Cleaning Exterior Cleaning (As Require d) Vinyl C lad (Black or White) Models: • Surfaces may be cleaned with a mild detergent and warm water solution. Do no t use solvent-based or abrasive cleaners. Use a so ft sponge and rinse with clean water .
8 ADA24 ADA SERIES Defr osting Automatic (Cycle) Defr ost Models Automatic defrost models do not produce frost in normal operating conditions. Howeve r , a fr ost pattern may be noticed on the interio r walls if the unit is repeatedly opened in a high heat or high humidity location.
ADA24 9 ADA SERIES Wire Shelf Re moval/Installation Reposition the shel ves as follows: Figure 10 1. Remove shelf retention clip. 2. Pull s helf ou t about 6" (Figure 10, 1) , until back of shelf clears the “hump” on the right-hand side. 3. Tilt up right-hand edge of sh elf (Figure 10, 2) .
10 ADA24 ADA SERIES Door Alignment Check and Adjustment IMPORT ANT IMPORT ANT Properly aligned, the door’ s gasket should be firmly in contact with the cabinet all the way ar ound the door (no gaps). Carefully examine the door’ s gasket to assure that it is firmly in contact with the cabinet.
ADA24 11 ADA SERIES Figure 15 5. Remove pivot screw from top hinge, invert screw and reinstall pivot screw in top hinge (Figure 15) . Do not install hinge on cabinet at this time. Figure 16 6. Remove bottom hinge from cabinet (four scre ws) and screws on opposit e side of cabinet (Figure 16) .
12 ADA24 ADA SERIES Before Calling for Service If your U-Line product appears to be ma lfunctioning, read through the OPERA TION section of this g uide to ensure th at the function of all controls are clearly understood.
ADA24 13 ADA SERIES T r oubleshooting Guide DANGER ELECTROCUTION HAZARD Never attempt to repa ir or perfor m mai ntenance on the unit until the main electrical power has been disconnected.
14 ADA24 ADA SERIES T roubleshooting - Models with an electronic display: PROBLEM POSSIBLE CAU SE REMEDY Electronic display is blank an d interior light is off with door open. Unit is in blackout/Sabbath mode (not Star K certified). Exit blackout/Sabbath mode (not Star K certified) (See OPERA TION).
ADA24 15 ADA SERIES Electronic Contr ol Quick Guide NOTE: 38°F is an example; the disp lay will vary with actual set-point. IMPORT ANT Factory recommended set-point is 38°F for r efrigerat ors and beverage centers, and 50°F for wine coolers. T ask T ouch T ouch Display Comment T urn ON/OFF Hold 10 seconds Release when °F flashes.
16 ADA24 ADA SERIES.
ADA SERIES U-Line Corporation Limited W arranty 1. U-Line Corporation ("U- Line") warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase.
For General Inquiries: P .O. Box 245040 Milwaukee, Wisconsin 53224-9540 U.S.A. Phone (800) 779-2547 F AX (414) 354-5696 www .U-Line.com For Service and Parts Assistance: Phone (800) 779-2547 (414) 354-0300 F AX (414) 354-5696 Email: OnLineService@U-Line.
An important point after buying a device U-Line ADA24RGL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought U-Line ADA24RGL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data U-Line ADA24RGL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, U-Line ADA24RGL you will learn all the available features of the product, as well as information on its operation. The information that you get U-Line ADA24RGL will certainly help you make a decision on the purchase.
If you already are a holder of U-Line ADA24RGL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime U-Line ADA24RGL.
However, one of the most important roles played by the user manual is to help in solving problems with U-Line ADA24RGL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device U-Line ADA24RGL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center