PKG-SVX14A-EN Installation, Operation, and Maintenance Midrange Self-Contained Units October 20 0 8 Models SCWH/SCRH 3, 5, 7.5, 10, 12, & 15-tons “AO” and later design sequence.
2 PKG-SVX14A-EN general information About This Manual Literature Change History Use this manual for commercial self- contained models SCWH and SCRH . This is the original issue of this manual. It provides specific installation, owner maintenance, and diagnostic troubleshooting instructions for “AO” and later design sequences.
PKG-SVX14A-EN 3 contents Cross reference to related publications/information: Midrange Self-Contained catalog, PKG-PRC012-EN Installation…………………………………………………2 gene.
4 P K G - S V X 1 4 A - E N I n s t a l l a t i o n g e n e r a l i n f o r m a t i o n M i d r a n g e M o d e l N u m b e r D e s c r i p t i o n F o l l ow i n g i s a c o mp l e t e d e s c r i p t i o n of t h e m i d r a n ge m o d e l nu m b e r .
PKG-SVX14A-EN 5 Installation general information General The midrange models SCWH/SCRH is a high efficiency , vertical air condioner . units have either front or top discharge configuration options and easy service access. Unit construction is heavy gage steel with a baked enamel finish.
6 PKG-SVX14A-EN Pre-Installation Considerations Pre-Installation Checklist Complete the following checklist before beginning unit installation. V erify the unit size and tagging with the unit nameplate. Make certain the floor or foundation is level, solid, and sufficient to support the unit and accessory weights.
PKG-SVX14A-EN 7 Installation pre-installation considerations 24" F AN ACCESS FRONT RETURN COIL / ELECTRIC HEA TER ACCESS MOTOR / DRIVE ACCESS (RIGHT SIDE) CONTROL BOX & CONDENSER F AN ACCESS .
8 PKG-SVX14A-EN Installation pre-installation considerations Service Access 10, 12, & 15-ton SCWH/SRCH with side-mounted fan configura- tion, field converted 10 through 15-ton SCRH/SCWH.
PKG-SVX14A-EN 9 Installation pre-installation considerations T able I-PC-1. Isolator load points, units with a vertical discharge configuration, lbs. model L1 L 2 L 3 L 4 L1 L2 L 3 L 4 SCRB/SIRB SCWB/SIWB 3-ton 99 105 120 127 105 133 118 1 24 5-ton 115 1 22 157 166 129 165 1 66 165 7.
10 PKG-SVX14A-EN Proper Lifting Procedure Follow these instructions and reference Figure I-PC-3. 1. Slide a fork lift into the opening provided on the unit base. Move the fork lift carefully . 2. Using slings, attach through the circular holes provided on the unit base.
PKG-SVX14A-EN 11 dimensions & weights Installation 3 & 5-tons SCWH/SCRH SCRH SCWH vertical discharge horizontal discharge (field converted) SCWH /SCRH dimensions & weight, in-lbs. unit shipping oper ating size A B C D E F G J K L M N O P Q R S weight weight 3 31.
12 PKG-SVX14A-EN dimensions & weights 7.5-tons SCWH/SCRH Installation SCWH vertical discharge horizontal discharge (field converted) SCWH /SCRH weight, lbs.
PKG-SVX14A-EN 13 dimensions & weights Installation 10, 12, & 15-tons with top-mounted fan configuration SCWH/SCRH horizontal discharge (field converted) vertical discharge SCRH SCWH SCWH /SCRH dimensions & weight, in-lbs. unit shipping operating tons A B C D E F G J K M N weight weight 10 66.
14 PKG-SVX14A-EN 10, 12, & 15-tons with side-mounted fan configuration, field converted SCWH/SCRH SCWH/ SCRH Dimensions, in. unit tons A C D E F G 10 65.75 7.04 18.07 57.28 66.93 25.79 12 65.75 7.04 18.07 61.22 66.93 29.73 15 80.31 19.83 19.83 61.
PKG-SVX14A-EN 15 dimensions & weights Installation Plenum Plenum dimensions & weight, in-lbs. unit size A B weight 3-ton 31.89 22.24 4 4 5-ton 36.41 24.01 5 4 7.5-ton 40.94 28.74 7 3 10 & 12-ton 65.75 29.52 1 20 15 -to n 80.31 29.52 1 4 6 A B C D E F G 0.
16 PKG-SVX14A-EN dimensions & weights Installation A B D C 0.43 0.28 0.39 0.39 1.03 1.03 1.08 1.57 3.19 0.75 0.75 5.90 1.00 NPT 1.38 1.38 17.50 20.26 1.38 8.27 2.18 0.59 9.54 9.54 15.89 2.18 9.07 7.48 0.59 BLOCKOFF (SHIPS DISASSEMBLED) Hot water coil 10 thru 15-ton units 35.
PKG-SVX14A-EN 17 mechanical requirements Duct Connections Install all air ducts according to the National Fire Protection Association standards for the “Installation of Air Conditioning and V entilation Systems other than Residence T ype (NFP A 90A) and Residence T ype W arm Air Heating and Air Conditioning Systems (NFP A 90B).
18 P K G - S V X 1 4 A - E N m e c h a n i c a l r e q u i r e m e n t s I n s t a l l a t i o n R e f r i g e r a n t P i p i n g ( A i r - C o o l e d U n i t s O n l y ) R ef e r en c e i n d us t ry r ec o m me n d at i o ns f o r a i r -c o o le d un i t r e f ri g e r a nt p ip i n g .
P K G - S V X 1 4 A - E N 19 e l e c t r i c a l r e q u i r e m e n t s I n s t a l l a t i o n S u pp l y Po w e r W i r i n g I t is t he i n s t al l e r ’ s r e s p o ns i b il i t y t o pr o v.
20 PKG-SVX14A-EN electrical requirements Installation RLA LRA qty. hp FLA qty. hp FLA qty SC*H0303.... 208-230V/60Hz/3Ph 12.9 77.0 0.5 2.21 1 18.3 30 3.15 19.3 30 SC*H0304.... 460V/60Hz/3Ph 5 . 7 35.0 1.00 8.1 15 1.42 8.5 15 SC*H0305.... 575V/60Hz/3Ph 4 .
PKG-SVX14A-EN 21 Installation Checklist Reference the checklist below to verify all steps required to successfully install a deluxe self-contained unit are complete. This checklist is intended to acquaint the installing personnel with what is required in the installation process.
22 PKG-SVX14A-EN pre-startup requirements Installation Pre-Startup Checklist Complete this checklist after installing the unit to verify all recommended installation procedures are complete before unit startup. This does not replace the detailed instructions in the appropriate sections of this manual.
P K G - S V X 1 4 A - E N 23 U n i t S t a r t u p P r o c e d u r e s 1 . C he c k al l e l ec t r i ca l c o nn e ct i o n s f or t i g h tn e s s . 2 . B e s u r e a l l u ni t ac c e ss o r ie s ar e p ro p e rl y s e t a n d i n st a ll e d . 3 .
24 PKG-SVX14A-EN Operation sequence of operation Sequence of Operation The thermostat controls the unit operation. It has both manual and automatic switches so the thermostat maintains desired comfort levels. The fan switch allows manual selection of the fan speed using the On or Auto setting.
PKG-SVX14A-EN 25 Maintenance general information T able M-GI-1. Midrange maintenance general data SCW H030 S CW H050 S CW H075 SCW H100 SCW H120 SCW H150 dimens ions, i n-lbs. height 66.93 78.74 78.94 91.54 95.47 95.47 length 31.89 36.41 40.94 65.75 65.
26 P K G - S V X 1 4 A - E N M a i n t e n a n c e m a i n t e n a n c e p r o c e d u r e s M a i n t e n a n c e P r o c e d u r e s T h i s se c t io n de s c ri b e s s p e c i f i c m ai n t e na n c e p r oc e d u re s t ha t m u s t b e p re f or m e d a s a pa r t of th e n o rm a l m ai n t en a n ce p ro g ra m .
PKG-SVX14A-EN 27 • T o assist in reducing power generation emissions, always attempt to improve equipment performance with improved maintenance and operations that will help conserve energy resources.
28 PKG-SVX14A-E N c on t ro l dis armin g rearmin g high pre ss ure control (air-cool ed & 12-ton water cool ed) 624±17.5 psig 464±29 psig high pre ss ure control (water-cooled except 12 -t on) 450±10 ps ig 348±14 .
P K G - S V X 1 4 A - E N 29 P e r i o d i c C h e c k l i s t s M o n t h l y C h e c k l i st T h e f o l l o w i n g c h e c k l i s t p r o v i d e s t h e r ec o m me n de d ma i nt e n an c e s c he d ul e t o k e e p t h e u n i t r un n i n g e f f ic i e n t l y .
30 P K G - S V X 1 4 A - E N M a i n t e n a n c e t r o u b l e s h o o t i n g T ro u b l es h o o t i n g U s e t he f ol l o wi n g s t e ps a n d p r oc e d ur e s t o he l p c o r re c t t h e s e co m m on p ro b l em s . P r o b l e m T h e e n t ir e u ni t do e s n o t o p e r a te .
P K G - S V X 1 4 A - E N 31 M a i n t e n a n c e t r o u b l e s h o o t i n g P r o b l e m I n s u f f i c i e n t c o o l i n g P o s si b l e c a u se 1 .
32 PKG-SVX14A-EN typical wiring diagram Maintenance.
PKG-SVX01A-EN 33 typical wiring diagram Maintenance.
34 PKG-SVX14A-EN typical wiring diagram Maintenance.
PKG-SVX01A-EN 35 typical wiring diagram Maintenance.
w w w . t r a n e . c o m F or m o re i n fo r m at i o n , c o n ta c t your local Trane o ff ic e or e -m a il u s at comfort@trane.com L i t e r at ur e Or d e r N u m b e r D at e S up e r s ed e .
An important point after buying a device Trane SCRH (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Trane SCRH yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Trane SCRH - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Trane SCRH you will learn all the available features of the product, as well as information on its operation. The information that you get Trane SCRH will certainly help you make a decision on the purchase.
If you already are a holder of Trane SCRH, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Trane SCRH.
However, one of the most important roles played by the user manual is to help in solving problems with Trane SCRH. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Trane SCRH along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center