Instruction/ maintenance manual of the product MS-SVN015-EN Trane
Go to page of 20
July 2007 MS-SVN015-EN Installation Manual NEW STYLUS TM Split System, 1-5 T ons Convertible T ype MCX Series 50/60 Hz 50 Hz Models Cooling Only MCX 512 GB MCX 518 GB MCX 524 GB MCX 530 GB MCX 536 GB .
MS-SVN015-EN © American Standard Inc. 2005 General Information General Information This Installation Manual is given as a guide to good practice in the installation by the installer of MCX mini-split system. Installation procedur es should be performed in the sequence that they appear in this manual.
3 MS-SVN015-EN Contents General Information 2 T ypical Installation 4 Location and Preparation of Units 5 Unit Installation 6 Connection of Refrigerant T ubing 7 Condensate Drain Piping 9 Electrical Installation 10 Remote Control Installation 11 T ypical Wiring Diagram 12 Dimensional Data 16 Notes 18 MS-SVN015-EN.
4 MS-SVN015-EN T ypical Installation Note: For models MCX 042, MCX 048, MCX 060 there ar e only two styles of installation: under ceiling and low wall Ceiling mounted Outdoor unit Indoor unit Floor mo.
5 MS-SVN015-EN Location and Pr eparation of Units 1. Select an appropriate position that allows every corners of the room to be uniformly air conditioned and where it is easy to route the refrigerant tubing. 2. Ensure that the floor or ceiling construction is sufficient to fully support the weight of the indoor unit.
6 MS-SVN015-EN 0.83"(21) 0.83"(21) 8.5"(215) B A Unit Installation Indoor Unit 1. Select a location to route tubing, wiring and drain pipe between the indoor and outdoor units. 2. Make a hole in the wall using a key hole saw or hole-cutting drill attachment.
7 MS-SVN015-EN Connection of Refrigerant T ubing The indoor unit refrigerant line connections are flar ed both 50 Hz and 60 Hz. Installation brazing, leak testing, and evacuation of refrigerant lines are cover ed in the Installer Manual, packaged with the outdoor unit.
8 MS-SVN015-EN Connection 9. For proper connection, align the union tube and flare tube straight with each other , then screw in the flare nut lightly at first to obtain a smooth match (Figure 17). 10. Tighten the flare nut to the specified tightening torque with torque wrench and adjustable wrench (Figure 18).
9 MS-SVN015-EN Condensate Drain Piping - The drain hose should run straight down the wall to a level where the runof f will not stain the wall. - There should be no traps. Avoid putting the end of the hose in water . - T o conveniently drain the system, the drain hose must slant downward, with a slope of at least 1 : 50 to prevent leakage.
10 MS-SVN015-EN Electrical Installation All wiring and grounding must comply with local electrical codes. 1. Wiring Important Safeguards: - Check the unit nameplate for electrical rating. Be sure wiring is done according to local codes and wiring diagram.
11 MS-SVN015-EN ECONO ECONO ON FAN COOL DRY HEAT AUTO OFF POWERCOOL SW Z Z MODE LOUVER SWEEP FRONT BLADE LIGHT OFF ON POWER COOL ECONO SLEEP SEND Locate and attach the wireless r emote control and wired contr ol as follows: 1. Do not place the control and the remote control near heat sources or expose to the direct rays of the sun.
12 MS-SVN015-EN T ypical Wiring Diagram J2 N C1 C2 L P20 J1 P17 P16 P19 P21 FREEZE P22 P26 2 1 P3 LINE-C EX-HI P7 P6 P5 P4 LOW MED HI NEUTRAL P2 LINE P1 BLK BLU RED YL BRW WHT WHT GRN/YL WHT RED RED BLK BLU RED YL INFRARED RECEIVER GRN/YL DESCRIPTION COIL BLK RED 1.
13 MS-SVN015-EN MCX042-060GB (50 Hz) MCX042-060G1 (60 Hz) INDOOR UNIT , COOLING ONL Y WITH CONTROL TYPE “R”, 3 SPEED 2 1 GRN/YL 1. FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2.
14 MS-SVN015-EN MCX512-536GB (50 Hz) MCX512-536G1 (60 Hz) INDOOR UNIT , COOLING ONL Y WITH CONTROL TYPE “W”, 4 SPEED GRN/YL 2 1 1. FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2.
15 MS-SVN015-EN MCX042-060GB (50 Hz) MCX042-060G1 (60 Hz) INDOOR UNIT , COOLING ONL Y WITH CONTROL TYPE “W”, 3 SPEED GRN/YL P21 FREEZE P22 ROOM DISPLAY P31 J2 GRN/YL 2 1 1.
16 MS-SVN015-EN Dimensional Data OUTLINE DIMENSIONS MCX512-536GB (EXPORT 50 Hz) MCX512-536G1 (EXPORT 60 Hz) MCX512GB/G1 MCX518GB/G1 MCX524GB/G1 DIMENSIONAL DATA MODEL CONN. SIZES TYPE AB C LIQUID SUCTION CONNECTIONS. IN. (MM.) IN. (MM.) EACH 1/4 (6.4) 1/2 (12.
17 MS-SVN015-EN DIMENSIONAL DATA NOTE 1) DIMENSIONS : MILIMETERS [INCHES] 25.4 MM. = 1 IN. MODEL CONN. SIZES LIQUID SUCTION TYPE CONNECTIONS. AB C D IN. (MM.) IN. (MM.) EACH IN. (MM.) MCX042GB/G1 MCX048GB/G1 BRAZED BRAZED 3/8 (9.5) 3/8 (9.5) 7/8 (22.2) 1-1/8 (28.
18 MS-SVN015-EN Notes MS-SVN015-EN.p65 6/27/07, 11:24 AM 18 Black.
19 MS-SVN015-EN Notes MS-SVN015-EN.p65 6/27/07, 11:24 AM 19 Black.
Trane A business of American Standard Companies www.trane.com For more information, contact your local district office Supersedes: Oct 2002 Stocking Location: Bangkok, Thailand Trane has a policy of continuous product and product data improvement and reserves the right to change design and specific ations without notice.
An important point after buying a device Trane MS-SVN015-EN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Trane MS-SVN015-EN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Trane MS-SVN015-EN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Trane MS-SVN015-EN you will learn all the available features of the product, as well as information on its operation. The information that you get Trane MS-SVN015-EN will certainly help you make a decision on the purchase.
If you already are a holder of Trane MS-SVN015-EN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Trane MS-SVN015-EN.
However, one of the most important roles played by the user manual is to help in solving problems with Trane MS-SVN015-EN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Trane MS-SVN015-EN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center