Instruction/ maintenance manual of the product GAT2A0C48S41SA Trane
Go to page of 20
Modular Multi-position Air Handler s GA T2A0B42S31SA GA T2A0C48S41SA GA T2A0C60S51SA PUB. NO . 22-1857-03.
2 Pub . No. 22-1857-03 Featur es and Benefits © 2012 T rane • Unique Cabinet Design - Double Wall F oamed and F or med Cabinet System - W ater Proof Cabinet Design - R-4.
Pub . No . 22-1857-03 3 Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benets 5 General Data 6 GA T2A0B42S31SA 6 GA T2A0C48S41SA 6 GA T2A0C60S51SA 6 P erf.
4 Pub . No. 22-1857-03 Optional Equipment Accessory Number Description Fits Cabinet Size BA YEAA C05BK1A Electric Heater , 5kW , Breaker , 24V Control, 1 Ph A to C BA YEAA C05LG1A Electric Heater , 5k.
Pub . No . 22-1857-03 5 Unique Cabinet Design Featur es and Benefits 5 Conduit Connections e Integrated Horizontal Drain P ans 6 T ool-less Door Fastener s w Compact 20.
6 Pub . No. 22-1857-03 General Data 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI ST ANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for perf ormance data. 2 3/4" Male Plastic Pipe (Ref .
Pub . No . 22-1857-03 7 General Data AIRFLO W PERFORMANCE GA T2A0B42S31SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1646 1495 1358 1522 1298 1138 0.1 1599 1464 1335 1489 1285 1137 0.
8 Pub . No. 22-1857-03 Per for mance Data GA T2A0C48 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C48S41SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 3 2 † 1 3 2 † 1 0 1904 1711 1541 1652 1455 1305 0.
Pub . No . 22-1857-03 9 Per for mance Data GA T2A0C60 AIRFLO W PERFORMANCE T ABLE AIRFLO W PERFORMANCE GA T2A0C60S51SA EXTERNAL ST A TIC (in w .g) AIRFLO W (CFM) Speed T aps - 230 V OL TS Speed T aps - 208 V OL TS 5 4 † 3 2 1 5 4 † 3 2 1 0 2169 1956 1874 1739 1633 2165 2033 1871 1736 1629 0.
10 Pub . No . 22-1857-03 Per for mance Data WIRING D A T A GA T2A0B42S31SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 2.
Pub . No . 22-1857-03 11 Per for mance Data WIRING D A T A GA T2A0C48S41SA Heater Model No. No. of Circuits 240 V OL T 208 V OL T Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection kW BTUH kW BTUH No Heater - - - 3.
12 Pub . No . 22-1857-03 Per for mance Data DIST ANCE FROM BELL Y B AND T O SHAFT F A CE OF MO T OR FOR MINIMUM VIBRA TION WHEEL BLO WER HOUSING BELL Y BAND M OTO R A A is determined per char t Wheel .
WIRING DIA GRAM FOR GA T2A0B42 AND GA T2A0C48 AIR HANDLERS.
WIRING DIA GRAM FOR GA T2A0C60 AIR HANDLERS.
Pub . No . 22-1857-03 15 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED COOLING • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat.
16 Pub . No . 22-1857-03 Field Wiring GA T2 AIR HANDLERS WITH SINGLE SPEED HEA T PUMP • * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage o.
Pub . No . 22-1857-03 17 GA T2 Conver tibility Multi-position Air Handler Airflow Airflow Airflow Upflow Condensate Drains Refrigerant Connections Horizontal Left* V er tical Upflow* (as shipped) Hori.
18 Pub . No . 22-1857-03 Dimensions GA T2 AIR HANDLER DIMENSIONAL D A T A D H W Model No . H W D GA T2A0B42 55.7 21.3 21.75 GA T2A0C48 56.9 23.5 21.75 GA T2A0C60 61.
Pub . No . 22-1857-03 19 GA T2 OUTLINE DRA WING MODEL NO . A B C D E F H FLO W CONTROL GAS LINE BRAZE GA T2A0B42 55.7 45.5 18.4 21.3 18.4 9.2 24.8 TXV 7/8 GA T2A0C48 56.9 46.7 20.5 23.5 20.5 10.3 24.2 TXV 7/8 GA T2A0C60 61.7 51.5 20.5 23.5 20.5 10.3 27.
T rane 6200 T roup Highway T yler , TX 75707 www .trane .com 03/12 The manuf acturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
An important point after buying a device Trane GAT2A0C48S41SA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Trane GAT2A0C48S41SA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Trane GAT2A0C48S41SA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Trane GAT2A0C48S41SA you will learn all the available features of the product, as well as information on its operation. The information that you get Trane GAT2A0C48S41SA will certainly help you make a decision on the purchase.
If you already are a holder of Trane GAT2A0C48S41SA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Trane GAT2A0C48S41SA.
However, one of the most important roles played by the user manual is to help in solving problems with Trane GAT2A0C48S41SA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Trane GAT2A0C48S41SA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center