Instruction/ maintenance manual of the product TL-SL2210WEB/TL-SL2218WEB TP-Link
Go to page of 64
U s er Guide Gigabit Uplink W eb Smart S wit ch TL-SL2210WEB/TL-SL2218WEB TL-SL2428WEB/TL-SL2452WEB Enterprise Networking Solution.
.
I Spe cif icati ons are subjec t to change without not ice. is a re g is t e r e d t ra d e ma rk of T P- L IN K T E C H N O L O GI E S C O., L TD. O th e r b r a n d s a n d p r o d u c t n a me s a r e t ra d e m a r k s o f t h e i r res pec ti ve holde rs.
II This Use r Guide is als o available in PDF on our website. T o obt ain the late st produ ct infor mation, please v isit the of f icial webs ite: ht tp: / /w w w .
III This Use r Guide is fo r: Net work Engine er Net work Administ rator Due to the s imilarity in s truc ture of TL -SL22 1 0WEB/ T.
IV Contents Chapter 1 Introduction ——————————————— 01 1.1 Product Overview ............................................................................................ 01 1.2 Fea tures ...........
V 5.3.5 Dynamic Binding ...................................................................................... 18 5.3.6 Ping ............................................................................................................... 19 5.4 VLAN Setting .
01 Gigabit Uplink Web Smart Switch Introduction The T L -SL 221 0WE B/T L -SL 221 8WEB/ TL -SL24 28WEB/ TL -SL2452 WEB Giga bit Uplink Web Smar t Switch is comp liant with the IEEE8 02.
02 Gigabit Uplink Web Smart Switch Introduction Front Panel The fr ont pane l of TL -SL 221 0WEB is sh own as the fo llowing f igure.
03 Gigabit Uplink Web Smart Switch RESET Pre s s this but t on fo r thr ee se co nds to re se t th e sof t ware set ting bac k to f ac to r y default s et ting.
04 Gigabit Uplink Web Smart Switch Rear Panel T h e r e a r p a n e l o f T L - S L 2 210W E B/ T L -S L 2218 W E B/ T L - S L 2428 W E B/ T L -S L 245 2W E B i s shown as th e following f igure. Rear Pane l Figur e 1 -5 Power So cket Connect the female connector of the power cord here, and the male connector to the AC power outlet.
05 Gigabit Uplink Web Smart Switch Make sure that the pack age cont ains t he following items. If any of the liste d items is damage d or miss ing, pleas e cont ac t your dist ributor .
06 Gigabit Uplink Web Smart Switch Site Requirem ent s T o ensur e normal ep er ation and lo ng ser vice life of the dev ice, ple ase ins t all it in an environme nt that me et s the re quireme nts d es cribe d in the fo llowing subs ec tio n.
07 Gigabit Uplink Web Smart Switch Ke e p t he d e vi c e f ar f r o m hi gh - fr e q u e nc y , s t r o n g- c u r re n t d ev i c e s, s u c h a s r a di o transmi t ting st atio n.
08 Gigabit Uplink Web Smart Switch Phillips scr ewdriver ESD -pr eventive wris t wrap Cable s Not e: The se to ols are n ot provid ed with o ur pro duc t. If nee ded, plea se se lf purc hase th em.
09 Gigabit Uplink Web Smart Switch 1 3 5 7 2 4 6 8 G IG A S FP 10 / 100 M b ps 10/100/1000Mbps 1000 M bp s 1 2 3 4 5 678 TL-SL2210WEB RE SE T 8+2G Web- Smar t S w i t c h Po w e r 1 00 M Li nk Act Sy .
10 Gigabit Uplink Web Smart Switch In th.
11 Gigabit Uplink Web Smart Switch Requirement s for C abling Indoors When cabling ind oor s, keep a cer t ain dis tan ce away from the devic es that may caus e h i g h -f r e q u e n c y i n t e r f e r e n c e s , s u c h a s d o w n - c o n d u c t o r c a b l e , p o w e r l i n e , p o w e r trans forme r and ele c trom otor .
12 Gigabit Uplink Web Smart Switch 2 ~ 5kVA power line Parallel c ablin g 300 One is in t he gro unde d met al rac eway or met al pip e 1 50 The both are in the grounded met al raceway or metal pipe 8.
13 Gigabit Uplink Web Smart Switch Pleas e c onne ct the Ethe rnet po r t of the Switc h to the net wor k dev ice s by R J45 c able s as the fo llowing f igure shown.
14 Gigabit Uplink Web Smart Switch Af ter c omple ting the in st allation, plea se verif y t he following it ems: The re are 5~ 10cm of cl earan ce aro und the side s of the devi ce for vent ilatio n and the air f low is ade quate.
15 Gigabit Uplink Web Smart Switch Sy s te m se t t.
16 Gigabit Uplink Web Smart Switch HD: ¾ half -duple x, th e por t suppor t s tran smis sion b et wee n the device and the clie nt in only one dire c tion at a tim e. FD: ¾ f ul l- d up l e x, t he p o r t s up p o r t s t ra n s mi s si o n b et we e n t he d ev i c e a n d i t s li nk par tne r in both dire c tions s imultane ous ly .
17 Gigabit Uplink Web Smart Switch The net work mo dule provide s the func tio n of s et ting the swit ch's IP addre ss, dynami c bi nd.
18 Gigabit Uplink Web Smart Switch A st atic M AC addre ss t able entr y c ontain s a MAC ad dres s and it s c orre spo nding swi tch por t.
19 Gigabit Uplink Web Smart Switch Th e p in g f u nc t i on is to t e st t he co n ne c t e dn e s s o f t he li nk b e t w e en th e sw it c h a nd destination.
20 Gigabit Uplink Web Smart Switch IEEE802. 1 Q T a g VL AN is divide d by VL A N ID ( VID ). When re cei ving a frame, the s witch che ck s th e VID in the ta g head er of t he frame to dec ide whic h VL A N it b elon gs to.
21 Gigabit Uplink Web Smart Switch If IEEE802.1 p pri ori t y mo de is conf i gure d, whe n a swi tc h por t rec ei .
22 Gigabit Uplink Web Smart Switch T he G i g ab i t U pl i nk We b S m ar t Sw i t c h i s m a na g e d v i a WE B p a g e s. T h e s m ar t an d frien dly inter fac es make the s witch mana geme nt an eas y job.
23 Gigabit Uplink Web Smart Switch Se condly , click th e “Se t tings ” but ton hinte d in Figure 6 - 1 , a new dialog will app ear: Se t tings D ialo g Figur e 6-2 In the cas e of IE5.0 , pleas e che ck th e optio n “Ever y visi t to the pa ge”; other wise, s ome wrong informatio n may show in WEB page s.
24 Gigabit Uplink Web Smart Switch A dialog will pop up a s bel ow . Se curi t y Se t ting s Figur e 6- 4 Four thl y , Sele c t the “Me dium” option of t he comb o box indicate d in Figure 6 -4, clic k the “Rese t ” but to n, and click “O K” to quit.
25 Gigabit Uplink Web Smart Switch Click the “S et tin gs” lab el, set the s cre en re so lution t o 1 02 4 x 768 and cli ck “O K” . All t he nec es sar y IE co nfigurat ion is co mplet ed. Suppo sing the s witch IP ad dres s is set a s 1 92.
26 Gigabit Uplink Web Smart Switch The Por t LED Indicator t able lies at the top of th e page. It provi des a visual 2. re pr es e nt ati on o f th e po r t s o n th e sw itc h f ro nt p ane l to dis play the st at us of th e por t s.
27 Gigabit Uplink Web Smart Switch On the l ef t side of t he page is the me nu tab le. It cont ains 8 main menu s. 3. Eac h menu has so me subme nus. Clic k on a me nu, it will open it s sub menu and t he main window di s p la ys t h e c on f i g ur a ti o n p ag e o f th e s ub m e n u l i s t f i r s t .
28 Gigabit Uplink Web Smart Switch TL -SL 24 2 8WEB Main Pa ge Figur e 6- 15 TL -SL 245 2WEB Main Pag e F igure 6 - 16 Sys tem set t ing co nt ains fo ur top ic s: s ys tem inform atio n, file trans fe r , reb oo t & res et and us er .
29 Gigabit Uplink Web Smart Switch Sof t war e Vers ion ¾ : Displays t he inst alle d sof t ware ver sion numb er . Hard ware Vers ion ¾ : Displays t he inst alle d device har dware vers ion numbe r . Sys te m De sc ript ion ¾ : Displays t he device m ode l number an d name.
30 Gigabit Uplink Web Smart Switch This page i s shown as b elow. Rebo ot & Res et Figur e 6- 1 9 A p rompt is disp layed i f a but t on is pre sse d.
31 Gigabit Uplink Web Smart Switch This pa ge cont ains the f ollowing f ield s: Por t Par amet er Figure 6 - 22 Por t S tat us: ¾ Indicat es whethe r the por t is o perat ional or non- ope rational.
32 Gigabit Uplink Web Smart Switch This pa ge displays th e por t s tati stic an d it cont ains the f ollowing entr ies: Por t St ati sti c Figure 6 - 23 T x C ollis ions ¾ : The numbe r of collisi on events e xpe rienc ed by the p or t.
33 Gigabit Uplink Web Smart Switch R X 128 t o 255 B ¾ : T ot al f rame s r ec ei ved wi th a le ng th of b et w ee n 128 and 255 oc tet s inc lusive, inc luding tho se with e rror s. R X 256 to 5 1 1 B ¾ : T ot al fram e s re ce ive d wi th a le ng th o f be t we en 256 an d 5 1 1 oc tet s inc lusive, inc luding tho se with e rror s.
34 Gigabit Uplink Web Smart Switch Stor m Co ntro l Figure 6 - 25 Bro adc as t C ont ro l: ¾ Enable or di sable the br oadc as t c ontrol to limit t he b roa dcas t frame s. Multi ca st Cont rol: ¾ Enab le o r di sa ble th e mult ic a st co ntr ol t o lim it th e mul ti ca s t frame s.
35 Gigabit Uplink Web Smart Switch This page cont ains the following topic s: swit ch IP addre ss, st atic MAC a ddre ss, f ilte ring MAC addre ss, dy namic binding, boun d MAC addre ss, aging t ime and ping.
36 Gigabit Uplink Web Smart Switch St atic M AC addre ss Figur e 6-28 A MAC addre ss and it s corr esp ondin g switc h por t sh ould be prov ide d when adding a st atic MAC ad dres s entr y . Search ¾ : Input the MAC addr ess in “ Mac Addre ss” f ie ld and clic k “S earc h” b ut ton.
37 Gigabit Uplink Web Smart Switch Ther e is eno ugh spa ce in st atic M AC addres s ta ble. The s tat ic MAC ad dres s t able is divided into several p age s. At mo st 10 e ntrie s can be held in on e page. T he but to ns “Fir st ” , “Previou s” and “Ne x t ” ca n be us ed to b rowse t he whole t able.
38 Gigabit Uplink Web Smart Switch This pa ge provide s the f unc tion of e nabling or dis abling dynami c binding. If dynamic bin ding i s di sable d, t he s witc h p or t learns M AC addr es s unlimite dly ( at mos t 80 00 ent ries c an be l earne d).
39 Gigabit Uplink Web Smart Switch State ¾ : Indicate s th e switc h po r t st ate t hat may be bin ding, free por t, s ecur e por t , unplugge d or "-- " . The de tail s are shown b elow: Free Por t: Th e binding func tio n is disab led, an d the po rt can lear n MAC addre ss freely .
40 Gigabit Uplink Web Smart Switch Furt he r exp lanat ion: The boun d MAC a ddre ss tab le cont ains all the MAC a ddre ss es boun d by th e switch por t s. Ever y ent r y cont ains one M AC addre ss and it s co rres pon ding por t numb er . The bo und MAC addres s tab le is divide d into several page s.
41 Gigabit Uplink Web Smart Switch Ping Figure 6 - 35 De st inat ion IP Addr e ss ¾ : Indicate s the IP Addr ess o f the te st de stinat ion. Ping Co unt ¾ : Indicate s the pin g times in on e submis sion. Dat a Size ¾ : Indicate s the dat a f ield le ngth of pin g packet .
42 Gigabit Uplink Web Smart Switch T hi s p a g e i s di s p l aye d w h e n t h e s wi t c h i s i n P o r t V L A N m o d e an d i t c o nt ai n s t h e following f iel ds: Por t V L AN S et tin g F igure 6 -3 7 VL AN ¾ : The V L A N numbe r .
43 Gigabit Uplink Web Smart Switch This page is dis played wh en t he s witch is in T ag VL A N mo de, t he gl obal set tin g of the por t s will af fec t all T ag VL ANs.
44 Gigabit Uplink Web Smart Switch T hi s p a g e i s d i s p la ye d w h e n t h e s w i t c h i s i n T ag V L A N m o d e a n d i t c o n t a i n s t h e follow ing f iel ds.
45 Gigabit Uplink Web Smart Switch Cle an Up ¾ : Clean up all me mber s of the V L AN. Submit ¾ : Submit to buil dup a VL A N with the s ele cte d me mber s. Not e: VID of th e VL A N must b e unique and within t he range of 1 to 4 09 4. At leas t t wo por t membe rs sh ould b e inclu ded t o add a V L AN gr oup.
46 Gigabit Uplink Web Smart Switch Por t T r unk ing Figur e 6- 43 Tr u n k ¾ : The T runk numb er . Member ¾ : S ele c t t he m embe r o f t he T r unk he re. Eac h gr oup has 4 op tional po rt s to comp ose a T r unk. St orm C ont rol ¾ : co nfigur e the stor m co ntrol for the T runk he re.
47 Gigabit Uplink Web Smart Switch Priori t y Mod e ¾ : Cont ains “Di sabl e” , “Por t-Base d” and “IEEE802. 1 p” . Priority Rule ¾ : Cont ains “Weighte d” and “F ixed”. If the pri orit y mode is s et to be “Dis able” , t he prio rit y rule c annot be c onf igure d.
48 Gigabit Uplink Web Smart Switch This pa ge is reveale d when t he “IEEE802. 1p” mode is c onf igure d. As shown b elow: 802.1 p Prior it y Fi gure 6 - 47 Priori t y T ag ¾ : The pri orit y t ag def ine d in IEEE802.
49 Gigabit Uplink Web Smart Switch Not e: T runk memb er p or t can b e neithe r Mirror P or t nor Mirr ore d Por t. The Mirr or Por t c an’t be t he Mirror ed Por t at t he same t ime.
50 Gigabit Uplink Web Smart Switch Troubleshooting The Power LED should be lit up when the power system works normally .
51 Gigabit Uplink Web Smart Switch Table of Factory Defaults T able of Fac tor y D efaul.
52 Gigabit Uplink Web Smart Switch Function Feature Def ault Setting VLAN Setting VLAN Mode Disable Port VL AN S etting All ports belong to VL AN 1 T ag VLAN Global Setting PVID 1 Untag Frame Pass T a.
53 Gigabit Uplink Web Smart Switch .
54 Gigabit Uplink Web Smart Switch Item Content Standards and Protocol IEEE 802.3 1 0Bas e- T IEEE802.3u 1 00B ase - T X IEEE802.3ab 1 00 0Ba se - T IEEE802.
55 Gigabit Uplink Web Smart Switch For m ore h elp, plea se go t o: ww w .tp-link .com/supp or t /faq.a sp T o dow nloa d the lat es t Firmwa re, Dr iver , Utilit y an d Use r Guid e, ple ase g o to: ww w .
.
W ebsite: http://www .tp-link.com E-mail: support@tp-link.com 7106503690 R ev: 2.0.0.
An important point after buying a device TP-Link TL-SL2210WEB/TL-SL2218WEB (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought TP-Link TL-SL2210WEB/TL-SL2218WEB yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data TP-Link TL-SL2210WEB/TL-SL2218WEB - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, TP-Link TL-SL2210WEB/TL-SL2218WEB you will learn all the available features of the product, as well as information on its operation. The information that you get TP-Link TL-SL2210WEB/TL-SL2218WEB will certainly help you make a decision on the purchase.
If you already are a holder of TP-Link TL-SL2210WEB/TL-SL2218WEB, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime TP-Link TL-SL2210WEB/TL-SL2218WEB.
However, one of the most important roles played by the user manual is to help in solving problems with TP-Link TL-SL2210WEB/TL-SL2218WEB. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device TP-Link TL-SL2210WEB/TL-SL2218WEB along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center