2 UL TRALINK UL2000M CAUTION: To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside; refer servicing to qualified personnel. WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture.
3 UL TRALINK UL2000M TABLE OF CONTENTS 1 . INTRODUCTION ......................................................................................................... 4 1.1 Before you get started ............................................................
4 UL TRALINK UL2000M 1. INTRODUCTION Thank you very much for expressing your confidence in the ULTRALINK Series by purchasing this unit. With the UL2000M from BEHRINGER, you have acquired a modern, high-performance wireless transmission system.
5 UL TRALINK UL2000M 1 . Keep the button (A) on the front side of the power supply pressed to release the plug. Pull the plug out and let go of the button. 2. Insert a different plug into the power supply unit. The plug is securely snapped into place when you hear a click.
6 UL TRALINK UL2000M 2. ULR2000 RECEIVER 2.1 Control elements and connections In this chapter, different control elements of your ULR2000 will be described, explained in detail, and you will get useful information on how to use them. 2.1.1 The front Fig.
7 UL TRALINK UL2000M COLOR CODE Each BEHRINGER ULTRALINK transmitter can be color-coded using a color ring; this way you can easily differentiate between multiple transmitters (set to different frequencies). To easily match a transmitter to a receiver, you can also attach color-coded strips to each receiver.
8 UL TRALINK UL2000M MUTE MUTE indicates that the ULR2000 ’s output is being muted . If the received and demodulated AF starts getting weaker, the noise increases; the signal-to-noise ratio gets smaller. The SQUELCH menu item lets you enter a threshold value (in dB) for the signal-to-noise ratio.
9 UL TRALINK UL2000M 4 . If a valid frequency value is set, press the SET button again. In the display, you are asked to enter where you want to save your settings. Depending on the basic settings (ch. 2.2.5) , the ULR2000 asks you to enter a channel color (BLUE, RED, .
10 UL TRALINK UL2000M 2.2.4 AUTO MUTE If the transmitter is turned on, off, or is switched to another channel without first muting the receiver, or if the transmission drops out due to weak batteries, audible noise will result. Even if the noise limiter is enabled on the receiver (ch.
11 UL TRALINK UL2000M Deactivating LOCK 1 . Press the SET button. LOC ON is shown in the display. 2. Press the UP or DOWN button once to select LOCOFF. 3. Press the SET button confirm, hence deactivating the keylock function. The procedure is now over, and the basic settings are shown in the display again.
12 UL TRALINK UL2000M 3. ULM2000 MICROPHONE 3.1 Control elements In this chapter, different control elements of your ULM2000 will be described, explained in detail, and you will get useful information on how to use them.
13 UL TRALINK UL2000M 1. Turn the selection switch to one of the positions 1 - 8, corresponding to the desired channel number. If a valid value is selected (i.e. neither 9 nor 0), the LED blinks quickly once as a confirmation. 2. Briefly press the POWER button.
14 UL TRALINK UL2000M 7 . After a second blink pause, an additional blink code is given as a confirmation: A successfully stored frequency is signaled with 2 slow blinks. The transmitter leaves the programming mode. If the LED blinks quickly 5 times, the frequency was not stored.
15 UL TRALINK UL2000M If no entry is made for more than 5 seconds (either on the selection switch or by pressing the POWER button), the LED blinks quickly 5 times, and the programming mode is aborted.
16 UL TRALINK UL2000M For the Auto Mute function to work, it has to be activated on both the transmitter and the receiver! Activating/deactivating the Auto Mute function 1. Engage MUTE. The transmitter can now be switched into the programming mode.
17 UL TRALINK UL2000M If the receiver is not powered on, no status is indicated. Briefly pressing the POWER button will neither turn the transmitter on nor off! 3.3.2 T ransmission frequency 1. Turn the selection switch to 9. The position of the MUTE switch is irrelevant.
18 UL TRALINK UL2000M 4. APPLICA TION EXAMPLE Fig. 4.1 shows how easy it is to use the products from the BEHRINGER ULTRALINK Series. Simply connect the balanced XLR output on the ULR2000 to the XLR input on your mixing console. Of course, you can use the receiver’s TRS output to connect to the next device in the signal path.
19 UL TRALINK UL2000M 5.2 Installation in a rack The ULR2000 ’s antennae are located in the front of the unit . This allows unproblematic installation in a rack. Each unit is delivered with a rack bracket and a connecting joint. This way, you can choose: 1.
20 UL TRALINK UL2000M 5.3 Audio connections The audio connections on the ULR2000 are laid out electronically balanced. Of course, you can connect unbalanced equipment to the balanced connectors. Fig. 5.2: XLR connections Fig. 5.3: 1/4 " TS connector Fig.
21 UL TRALINK UL2000M Please ensure that only qualified personnel install and operate the ULM2000. During installation and operation, the user must be sufficiently grounded. Electrost atic charges might affect the operation of the unit. 6. SPECIFICA TIONS 6.
22 UL TRALINK UL2000M 6.2 ULM2000 microphone RF characteristics Modulation wideband FM Frequency range 794 - 810 MHz Transmission frequencies (for EU/US/CA) 320 frequencies, between 798.1 - 805.9 MHz, adjustable in 25 -kHz increment s Channels 8, freely programmable and switchable Channel bandwidth < 200 kHz Channel spacing (min.
F EDER AL C OMMUNICA TIONS C OMMIS SION C OMPL IANC E INFORMA TION Responsible par t y name: MUSIC G rou p Ser v ices USA , In c. Address: 1 891 2 Nor t h Cree k Park way, Suite 2 00 B oth ell , WA 980 1 1 , USA Phone/ Fax No.
24 UL TRALINK UL2000M MICROPHONE QUICK ST ART GUIDE MICROPHONE QUICK ST A RT GUIDE.
An important point after buying a device Behringer A50-13413-00005 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Behringer A50-13413-00005 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Behringer A50-13413-00005 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Behringer A50-13413-00005 you will learn all the available features of the product, as well as information on its operation. The information that you get Behringer A50-13413-00005 will certainly help you make a decision on the purchase.
If you already are a holder of Behringer A50-13413-00005, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Behringer A50-13413-00005.
However, one of the most important roles played by the user manual is to help in solving problems with Behringer A50-13413-00005. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Behringer A50-13413-00005 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center