Description / Applications The Beckett GeniSys TM Advanced Burner Control is a 120 V ac primary safety control for residential and light commercial oil burners used in boiler , furnace, and water heater applications having fi ring rates less than 20 GPH.
2 T able 1 - Models and Cross Reference Guide Beckett GeniSys Control Part No. Lockout Time V alve-on delay time 2 Motor-off delay time 2 Replaces Honeywell: Replaces Carlin: 7505A 0000 15 sec - - R71.
3 120v GeniSys Control Installation and Operation Manual Optional Snap-on Display Module: For programming and diagnostics Optional Snap-on Alarm Module: For adding isolated low voltage alarm contacts to the base control. See Alarm Module Instructions for speci fi cations.
4 Electrical Ratings Inputs: V oltage: 120 V ac nominal (102 to 132 V ac) Current: 100 mA nominal (150 mA max at 132 V ac) Frequency: 60 Hz Outputs: Motor: 120 V ac, 10 full load amps (FLA), 60 locked rotor amps (LRA) *Note: Reduce motor FLA rating by igniter current Igniter: 120 V ac, 3 A @ 0.
5 120v GeniSys Control Installation and Operation Manual The control can malfunction if it gets wet, leading to accumulation of oil or explosive oil vapors. Never install where water can fl ood, drip or condense on the control. Never use a control that has been wet - replace it.
6 Figure 3 – 7505A (for replacement of R7184A) Interrupted ignition, no valve-on or motor-off delay ► Figure 4 – 7505B (for replacement of R7184B) Interrupted ignition, valve-on delay only (no m.
7 120v GeniSys Control Installation and Operation Manual T ypical Furnace Wiring: Figure 6 – 7505A (for replacement of R8184G) Intermittent ignition, no valve-on or motor-off delays ► SAFETY AND O.
8 Star tup / Check out If the burner or control fails any of the following tests, recheck control wiring. If the burner or control still fails any tests, replace the control. Starting the System Open the shut-off valves in the supply line from the oil tank.
9 120v GeniSys Control Installation and Operation Manual 2 1 3 5 6 8 4 7 Standby Motor-off delay V alve-on delay T rial for ignition Ignition carryover Run Lockout Recycle 9 Pump prime is then sent to Motor-Off Delay , if applicable, or it is shut down and sent to Standby .
10 If the burner is in the below state: Pushing the reset button will: Button Click (press < 1 second) Button Hold (press > 1 second) Button Hold (press 15+ seconds) Lockout Reset from Soft Lock.
11 120v GeniSys Control Installation and Operation Manual automatically return to standby mode . If prime is not established during the four minute pump prime mode, return to step 5 to re-enter Pump Prime mode. Repeat steps 5 through 7 until the pump is fully primed and the oil is free of bubbles.
Form No. 61649 R14, Printed in USA 10/10 CORPORA TION USA: P.O. Box 1289 ● Elyria, OH 44036 Canada: R.W. Beckett Canada, Ltd. ● Unit #3, 430 Laird Road ● Guelph, Ontario N1G 3X7 www.
An important point after buying a device Beckett Model 7505 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Beckett Model 7505 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Beckett Model 7505 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Beckett Model 7505 you will learn all the available features of the product, as well as information on its operation. The information that you get Beckett Model 7505 will certainly help you make a decision on the purchase.
If you already are a holder of Beckett Model 7505, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Beckett Model 7505.
However, one of the most important roles played by the user manual is to help in solving problems with Beckett Model 7505. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Beckett Model 7505 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center