SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE, LOW ENERGY AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.
DWG NO SIZE SHEET SCALE CAGE CODE PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: ENG'G FILE OF: DRAWN BY: REV 01 24 VAC MC-25 #1 PUSH PLATE D.
DWG NO SIZE SHEET SCALE CAGE CODE A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: FILE OF: DRAWN BY: REV TITLE: PAIR OF DOORS WITH MC25, ELECTRIC.
PH: (412) 249-4100 FAX: (412) 249-4101 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: SHEET: SCALE: A REV: DRAWN BY: SIZE: CAGE CODE: DWG NO: FILE OF: B.
.
A FILE OF: DRAWN BY: 1 OF 1 NTS CAGE CODE: DWG NO: REV: SIZE: SHEET: SCALE: DATE: NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS.
SIZE: DRAWN BY: TITLE: MC-25 w/ SARGENT EL PANIC DEVICE & AUTOMATIC DOOR OPERATOR A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, APT. BUZZER RELAY/ FIRE ALARM A NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VO LT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE.
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVERS, SEPARATE POWER SUPPLY FOR MAGLOCK, NIGHT MODE RELAY A NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS. 2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLT S).
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE.
DWG NO SIZE SHEET SCALE CAGE CODE PH: (412)782-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: NONE FILE OF: DRAWN BY: REV MC25 #2 TRANSFORMER KM 2000 DOOR CONTR.
SIZE: DRAWN BY: TITLE: MC-25 WITH 3 WIRE RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, MAGNETIC LOCK, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC PANIC, PUSHPLATE AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.
SIZE: DRAWN BY: TITLE: 2 MC-25s WITH ELECTRIC STRIKE, SEQUENCING 2 DOOR PANELS A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC STRIKE.
SIZE: DRAWN BY: B 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL : www.be ase nso rs. com REV BY: KJG JDC SCALE: DATE: NONE 20 MARCH 2006 PART NO: SHEET 1 OF 1 80.
An important point after buying a device BEA 80.0011.02 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought BEA 80.0011.02 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data BEA 80.0011.02 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, BEA 80.0011.02 you will learn all the available features of the product, as well as information on its operation. The information that you get BEA 80.0011.02 will certainly help you make a decision on the purchase.
If you already are a holder of BEA 80.0011.02, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime BEA 80.0011.02.
However, one of the most important roles played by the user manual is to help in solving problems with BEA 80.0011.02. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device BEA 80.0011.02 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center