Instruction/ maintenance manual of the product GMD1-60N Thermo Products
Go to page of 44
THERMO PRODUCTS, LLC. POST OFFI CE BOX 2 17 NORTH JUDSON, IN 46366 PHONE: (574) 896 - 2133 MG - 505 ECN 5 320 - MA 1 30307 M ADE IN USA GAS - FIRED FURNACE DOWN FLOW & DIRECT VENT (SEA LED COMBUSTION) MODELS: GMD1 -60N and GMD1-80N INSTA LLA TION A ND SERVICE M A NUAL For ins tallati on in: 1.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 1 I. SA FETY SECTION This page a nd the follow ing tw o pages contain various w arnings and cautions found throughout this furnace S ervice and Instal lation Manual.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 2 after t urnin g off the g as supply. A final t est fo r gas leakage m ust be mad e after purging the gas l i ne . : DO NOT wet ele c tronic compone nts during the lea k test.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 3 This page a nd the follow ing page c ontain reproduc tions of the various w arning and instruction l abels placed on th e Thermo P ride Gas Fu rnace. Please read and comply w ith the con tent s of t hese labels.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 4.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 5 TA BLE OF CONTENTS SECTION BEGINNING PA GE I. SAFETY SECTION 1 II. GENERAL INST RUCT IONS A ND CLEARA NCES 6 III. FURNACE SPECIFICATIONS 8 IV. INSTALLATION 10 A. ROOF JACK 10 B.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 6 II. GE NE RA L INSTRUCTIONS AND CLEA RA NCES NOTE: REA D THIS SECTIO N BEFORE STARTING INSTALLA TIO N 1. This furnace is eq uipped w ith or ifices for oper ation w ith natural gas.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 7 : The area aro und t he fur nace must b e kept f ree and clear o f combust ible mat erials, especiall y papers and rags. : This fu rnace is no t to be used as a con struct ion h eater.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 8 III. FURNA CE SPECIFICA TIONS MODEL GMD1 - 60 GMD1 - 80 HEAT I NPUT RAT E (BT UH) 60,000 80,000 HEAT I NG CAPACI T Y (BTUH) 49,000 65,000 BURNER ORIFI CE - NAT. GAS (MM) #38 2.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 9 BLOWER DATA GMD1 - 60 MANUFACT URE R: MORRISON P RODUCTS , INC. BLOW ER MODEL: 10 - 7, DIRECT DRI V E NOMINAL MOTOR POW ER OUTPUT (HORSEPOW ER): 1/3 TYPICAL AIRFLOW @ SPECIFIED EX TERNAL STATIC PRESSURES (SCF M @.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 10 IV. INSTA LL A TION A . ROOF JA CK The roof jack assembly and acces sories must be lis ted by a nati onally recog niz ed testing agency for the appropr iate heating fuel.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 11 Combustible Floor Ba se Model: 70 - B AS E Figure 1A Cott age Base Model: 01C OT - BA SE Figure 1B Coil Cabine.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 12 D. BA SE INSTA LLA TION 1. Combustibl e Floor Bas e Model: 70 - BASE Use the base bottom panel as a template to mark floor opening locations (see Fig ure 2). C ut a squar e opening i n the floor for the suppl y air connector duct.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 13 If th e combust ion air p assageway cann ot ter minate o utside o f th e skirting or enclosure , a perma nent .
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 14 CA UTION: A perma ne nt opening with a mi ni mum of 50 squa r e inches of unobstruct ed infiltra tion (free are a ) for ventilation a nd combustion ai r must be provided to the inte r i or of the structure.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 15 F. CLOSET INSTALLA TIO N WA RNING: HAZARD OF ASPHYXI ATION: A suc ti o n effect will occur w hen th e furnace is operating insi de the closet wi th the c loset door closed.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 16 4. The total free area of opening s in the floor or ceili ng reg ist ers ser ving the retur n air sys tem must be at least 350 sq uare i nches.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 17 plate is s upplied w ith the furnace for adapt ing the 3 - inch round flex combustion ai r duct to the 2 -i nch x 7 - inch c ombustion air duct.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 18 H. GA S PIPING : Because of the po tent ial of t he odo rant t o fade, a g as leak may not be detected by smell. If this f urnace is i nstalled below gr ade, cont act your gas supplier for a gas d etecto r.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 19 design - certified to be r esist ant to the action of the LP g ases shoul d be used on all threaded joi nts. The burner is s etup to be piped to the g as supply throug h the left - hand si de of th e furnace.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 20 f. Rei nstall and s ecure the junc tion box cov er w ith the ori ginal mounting s crew s. 3. Connection O f Room Thermostat W ires NOTE: Class 1 t hermost at wire must be u sed insid e the f urnace bu rner compartment.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 21 J. INITIAL STA RT UP: This furnace does not hav e a pilot. It is eq uipped w ith a hot sur face ig nit er, whi ch automaticall y l ights the burner. D o not attempt to li ght the bur ner by hand.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 22 BTU at sea lev el must be reduced to a firing rate of 64,000 (80,000 x .80 = 64, 000 ) at an elevation of 5,000 f eet. If the f urnace is i nstalled at an elevat ion of 2,000 feet or less, no reduction in input is requi red.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 23 This gas furnac e is equi pped w ith a fixed or ifice si zed for the manifold pr essure s hown on the rating label. The input can only be incr eased, or decr eased, by adjusting the manifold pressur e.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 24 Figure 8 M. SETTIN G TEMPERA TURE RISE The GMD1 - 60N and G MD1 - 80N is desig ned and w ired at t he factory for a heati ng blow er speed that shoul d resul t in an approx imate temperat ure ris e of 70 ° F.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 25 N. FURNA CE CHECKOUT PROCE DURE Before any sy stem of gas pi ping i s finally put int o serv ice, i t shal l be carefull y tested to assure that it is g as tig ht as indic ated in secti on IV.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 26 V. INSTALLER'S INSTRUCTIO NS TO USER: After comp leting the installation, the installer shall i nform and/or demonstrate t o the homeowner: 1.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 27 VI. STARTING THE UNIT FL AM E M UST BE DETECTED W ITHI N 4 SECO N DS I F F L AME IS DE TECTED, THE DELA Y- TO-.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 28 AFTE R D ELAY-T O -FAN --ON PERIO D E NDS, C IR CULAT ING AIR FAN IS ENE RGI ZED AT HE AT IN G SPEED . TH E (OPT I O N AL) ELEC T RO N IC AIR CLEAN ER AND HU MIDIFIER AR E EN ERG IZED.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 29 VII. TROUBLESHOOT ING THIS SECT I ON IS ONLY TO BE P ERFORMED BY TRAINED, QUA LIFIED SERVI CE PERSONNE L, A ND NOT BY THE FURNA CE OWNER. NOTICE: BEFORE TROUBLESHOOTING, FAMILIARIZE YOU RSELF W IT H T HE STA RT UP AND CHE CK OUT P RO CEDURE.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 30 DIA GNOSTIC FEATURES : P ower must b e disconn ected bef ore servici ng . The 50A65 - 143 control c ontinuously monitor s its ow n operat ion and the operati on of the sys tem.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 31 TURN THERMOSTAT TO CALL F OR HEAT DOES THERMOSTAT MAKE CONTAC T? REPLACE TRANSFORMER CHECK INPUT POW ER, SERVI.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 32 CHE CK THE I NTEG RATE D CONT ROL DI AG N O STI C LED LA MP. RESET BY I NTER RUPT I NG POW E R TO CON T ROL F OR MOR E THA N O NE SECO ND. IF LED ST AY S ON CO NT I N UO USL Y , REPL A CE I NTEG RATED C O NTRO L .
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 33 AFTER G AS VALVE OPEN S, DO TH E BURN ERS IGNIT E? MEASURE MANIFOLD PRESSUR E.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 34 TRO UBL ESHO OTI NG COM PL ETE. CH ECK AL L W I RIN G F OR LOO SE CONNEC TIO NS IS L ED L I GHT ON I NTEGR ATE.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 35 VIII. DE A LER MA INTENA NCE A qualified heating c ontractor should pe rform the follow ing mai ntenan ce procedu res at th e beginn ing of each heat ing season .
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 36 Figure 9 C. INDUCER BLOW ER A SSEMBLY Inspect the pr essure sw it ch and tubing connections and inspect the bl ower /assembly for war page, deter iorati on and carbon or other build - up.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 37 Vent pipes shoul d also be ins pected for any s igns of corrosi on, deterior ation, or l eakage that may caus e combustion by - produc ts to infiltr ate the home or indoor envi ronment.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 38 IX. USER INFORM A TION SEC TION A . WA RNINGS A ND CA UTIONS: : If you suspec t there is a problem with the furna ce, perta ining to the venting system or an y oth er related p roblem , immediat ely cont act a quali fied service agency.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 39 B. COMPONE NT L O CA TIONS The followi ng diag ram show s a ty pical furnace instal lation and ty pical positi on of the components referenced i n these inst ructions .
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 40 1. VESTIBULE: The furnace v estibule ar eas or bur ner compartment s hould be inspected by remov ing front doo.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 41 A PPEND IX A – REPLA CEMENT PA RTS.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 42.
A ll installation s and services mu st be perfo rmed by qualified serv ice personn el. 43 A PPEND IX B – WIRING DIA GR AM.
An important point after buying a device Thermo Products GMD1-60N (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Thermo Products GMD1-60N yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Thermo Products GMD1-60N - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Thermo Products GMD1-60N you will learn all the available features of the product, as well as information on its operation. The information that you get Thermo Products GMD1-60N will certainly help you make a decision on the purchase.
If you already are a holder of Thermo Products GMD1-60N, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Thermo Products GMD1-60N.
However, one of the most important roles played by the user manual is to help in solving problems with Thermo Products GMD1-60N. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Thermo Products GMD1-60N along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center